3. Mounting Product

Cutting Guide

LINN is a specification grade product, and all power feeds and end caps are factory 
moulded. There are occasions where LINN may need to be cut, and this can be done 
by taking note of the minimum cutting distances which differ between versions. 
Reference should be made to this guide, data sheets and the indicated scissor/cut 
marks on the product itself. The cut lengths must then be fitted with an appropriate IP 
rated end cap (available separately from the LINN catalogue). 
For guidance when installing the end cap, please contact technical support. 
Note that when cutting LINN Pixel products, the number of LED nodes and control 
addresses will reduce which may impact an SPI/DMX signal patch. Care should be 
taken to ensure cut lengths are catered for in control programming interfaces and 
address allocations.
 

General Mounting

LINN can be fastened to surfaces using appropriate accessories available from EPS 
Lighting. Please refer to data sheets or contact technical support for a copy. The 
use of glues and resins as fixing agents should be avoided. Use of glues and resins 
may invalidate the warranty of the product, unless it’s use is agreed in writing by EPS 
Lighting as part of a detailed project specification. 
The images indicate one type of fixing available in the accessories range. The different 
fixings serve obvious purposes, however when in doubt technical support should be 
contacted.
Quantities of accessories and fixings are dependent on the type and its effect on the 
variant LINN it’s being used with. Care should be taken to ensure drooping is avoided, 
and to ensure that LINN is fastened adequately to avoid stresses on LINN itself. 
 

LED

PCB

PVC

Light surface

Cutting line

Screw

Aluminium  

profile

Installation  

surface

Power Feed Options

LINN comes with a choice either bottom, side and end moulded power feeds which 
can be used for various installation methods to ensure hidden cables and a seamless 
lines of light. The type of feed can be found on order forms, catalogues and data 
sheets. 
 

 

Summary of Contents for LINN Series

Page 1: ...LINN Series USER MANUAL...

Page 2: ...nts 1 Introduction p3 2 Product overview p4 Top Flat in RGB MONO RGBW PIXEL p4 Side Flat in RGB MONO RGBW PIXEL p5 Side Round in RGB MONO RGBW PIXEL p5 3 Mounting product p8 Top Flat and LINN Top Flat...

Page 3: ...ters for high end exterior illumination systems covering flood grazing wash spot and media facade solutions You can visit Elumeros website by visiting www elumeros com LINN Series Are you looking for...

Page 4: ...d design and support service to all our customers Please speak to your local representative or distributor for more information UV PROTECTED CLASS III IP68 CORROSION RESISTANT IK08 DIRT RESISTANT SALT...

Page 5: ...MIN BENDING DIA 8cm MONO DIA 12cm RGB MIN LENGTH 8 3cm MAX LENGTH 10m CONTROLS DMX RDM RGB COLOUR OPTIONS DW PIXEL RGBW 11 5mm 21mm Bending direction LINN Side Round in RGB MONO RGBW PIXEL Visually dr...

Page 6: ...e supporting structure must be capable for the installation of luminaires and advice must be taken from an appropriately qualified and competent person to verify proposed mounting positions and surfac...

Page 7: ...t is recommended that you do not cover or conceal it Do not route the product through walls doors windows or building structures Do not roll out the product onto rough surfaces or over sharp corners T...

Page 8: ...Mini LINN must be installed by at least 2 people who can support the product in various locations as shown During installation care should be taken to ensure the bending radius of LINN is not exceeded...

Page 9: ...various locations as shown During installation care should be taken to ensure the bending radius of LINN is not exceeded LINN Side Flat LINN Side Flat LINN Side Round LINN Side Round General Do NOTS T...

Page 10: ...fastened to surfaces using appropriate accessories available from EPS Lighting Please refer to data sheets or contact technical support for a copy The use of glues and resins as fixing agents should b...

Page 11: ...nsure the operating voltage is constant constant voltage A maximum volt drop of 5 is allowed for example at 24Vdc the maximum voltage drop would be 1 2V meaning a delivered voltage of 22 8V to the fix...

Page 12: ...contact epslighting com www epslighting com Please note Lumen performance and colour temperature typical values and due to production processes and the nature of LEDs and electronics values for outpu...

Reviews: