Safety and operating instructions
© Construction Tools PC AB | 3390 5211 01 | 2020-09-18
Original Instructions
21
WARNING
Hands and fingers being cut off or hurt
Bores and surfaces can act like a pair of scissors and
cut off or hurt parts of your body.
u
Never use your fingers to check bores or fitting sur-
faces.
n
Let your assistant instruct you until the bores in the
adapter plate (B) and in the stick (A) are properly
aligned.
n
Install the stick bolt (C) and lock it.
A
B
C
D
n
Lift the hydraulic attachment (D).
A
B
G
E
F
n
Extend the bucket cylinder (E) until the bore in the
linkage (F) aligns with the bore in the adapter
plate (B).
n
Install the linkage bolt (G) and lock it.
n
Carefully move the bucket cylinder (E) into both end
positions.
The adapter plate must not be stopped by the mechani-
cal stops in either position. Consult the Epiroc Customer
Center / Dealer in your area if the adapter plate is
stopped by a mechanical stop.
5.5.2 First installation
WARNING
Risk of death due to defective first in-
stallation
Faults during the first installation or commissioning can
lead to life-threatening situations and may cause consid-
erable damage to property.
u
Have the first installation exclusively conducted by
authorised specialist personnel.
u
Do not undertake unauthorised first installation.
WARNING
Unexpected movement
Sudden movements of the carrier may cause serious in-
jury.
u
Secure the carrier such that it cannot move unex-
pectedly.
u
Observe the carrier manufacturer’s instructions.
NOTICE
Damage due to incorrect oil pressure setting
Incorrect oil pressure setting can result in severe dam-
age to property and the environment.
u
Before installing the hydraulic attachment to the car-
rier check the oil pressure setting of pressure line
»P«
with a hydraulic flow tester.
u
Check the tank/return line pressure with an additional
manometer mounted between hydraulic flow tester
and tank line
»T«
.
u
Ensure the technical specifications are fulfilled (see
chapter
Technical specifications
).
5.5.3 Install separate leakage oil line
The separate leakage oil line including separate leakage
oil filter must be installed from the shut-off valve on the
boom to the carrier's hydraulic oil tank. The operator
must pre-install a suitable connection on the carrier's hy-
draulic oil tank for the leakage oil line.