381
Options 3 and 7 must be off for automatic SIA and CID reporting
To enable keyswitch arming/disarming and make it work properly, program the following
sections:
Section
Entry/Description
001
Program a zone as type 22 for momentary keyswitch arm
009
Program a PGM as 05 for system arm status
5.2.3.
PC 5010
Sections Programing Description
015
Turn options 4 on and options 7 and 8 off
301
Enter any phone number
310
Enter an account number for each partition
360
Enter 03 for CID or 04 for SIA reporting
361-362
Turn option 1 on for each partition alarm/restore reporting. 361 is for
partition 1, 362 is for partition 2.
365-366
Turn option 1 on for each partition open/close reporting. 365 is for
partition 1, 366 is for partition 2.
380
Turn option 1 on to enable communicator for digital monitoring option.
Options 3 and 4 must be off
.
Note: I
f Keybus monitoring reporting is selected, option 1 must be off.
381
Options 3 must be off for automatic SIA reporting. All CID codes from
section 320 to 353 must be manually entered when CID reporting is
used.
To enable keyswitch arming/disarming, program the following sections:
Section
Entry/Description
001
Program a zone as type 22 for momentary keyswitch arm
009
Program a PGM as 05 for system arm status
5.2.4.
PC580, PC585, PC 1555
Sections Programing Description