27
EPH Controls Ltd.
22˚C
21˚C
20˚C
19˚C
18˚C
17˚C
Temp
Time Minutes
Heating On
Heating Off
Target Temperature
Proportional Bandwidth
20
0
40
60
80
100
Graph (27.1): TPI Control
Pb -Proportional Bandwith
2°C
This value refers to the temperature below the target at which
the thermostat will start to operate in TPI control. You can set this
temperature from 1.5°C to 3.0°C in 0.1°C increments.