NOTE: In the mode of Light ON/OFF and Light ON/Timer, the Load is
turned on after 10Min. delay.
7. Optional Accessories
Accessory 1:
Wireless collector (eBox-WL433M-01)
Accessory 2:
Super Parameter Programmer
—
SPP-02.
Use USB to RS485 converter cable: CC- RS485-RS485-150U-22AWG
Accessory 3:
PC monitoring setting software “Solar Station Monitor”
Use USB to RS485 converter cable: CC-USB-RS485-150U-22AWG
Accessory 4:
Mobile APP, IAM (Ir-Android-Micro).
Use USB to RS485 converter cable: CC-USB-RS485-150U-22AWG
Use OTG cable: OTG-12CM
APP software can be downloaded from the website of
Accessory 5:
Fixed Plate (Four)
Overall dimension
:
20×18×6mm/Mounting hole size
:
Φ3.5mm
Note: Accessory 2-4 can set the controller parameters, please refer to the user
manual of accessory.
8. Protection
Protection
Conditions
Status
PV Reverse
Polarity
When the battery is correct connecting, the
PV can be reversed.
The controller is not
damage
Battery Reverse
Polarity
When the PV is not connecting, the battery
can be reversed.
Battery Over
Voltage
The battery voltage reaches to the OVD
Stop charging
Battery Over
Discharge
The battery voltage reaches to the LVD
stop discharging
Battery
Overheating
Temperature sensor is higher than 65
℃
Output is OFF
Temperature sensor is less than 55
℃
Output is ON
Lithium battery
Low Temperature
Temperature sensor is less than the low
temperature value(Default 0
℃
)
Lithium battery stop
charging/discharging
Temperature sensor is higher than the low
temperature value(Default 0
℃
)
Lithium battery
charging
Load Short
Circuit
Load current ≥2.5 times rated current
One short circuit, the output is OFF 5s
;
Two short circuit, the output is OFF 10s
;
Three short circuit, the output is OFF 15s
;
Four short circuit, the output is OFF 20s
;
Five short circuit, the output is OFF 25s
;
Six short circuit, the output is OFF
Output is OFF
Clear the fault:
Restart the controller
or wait for one
night-day cycle
(night time>3 hours).
9. Troubleshooting
Faults
Possible reasons
Troubleshooting
LED Charging
indicator turn off
during daytime
when sunshine falls
on PV modules
properly
PV
array disconnection
Confirm that PV and battery wire
connections are correct and tight
No LED indicator
Battery voltage maybe
less than 9V
Measure battery voltage with the
multi-meter. Min.9V can start up the
controller
Battery LED
indicator green fast
Flashing
Battery over voltage
Check if battery voltage is higher
than OVD, and disconnect the PV
Battery LED
indicator red
Battery
over discharged
①
When the battery voltage is restored
to or above LVR point (low voltage
reconnect voltage), the load will
recover
Battery LED
indicator red
flashing
Battery Overheating
The controller will automatically turn
the system off. But while the
temperature decline to be below 50
ºC, the controller will resume.
Powering on
normally, the load is
off
①
The connecting
wires are error or
virtually connected
②
Load mode is not
appropriate.
③
This controller does
not match with the LED
light.
④
Output short circuit.
①
Check the connecting cable.
②
Check the load’s mode and
parameters.
③
The voltage of LED light is not
within the output voltage range of
controller.
④
Check the connecting cables and
LED light.
The dimming
function is invalid
The controller does not
match with the LED
light source.
This
product is a step-up
voltage control,
If input
voltage is lower than
the rated voltage, it is
not working.
①
Replace the LED light
②
Reduce system rated voltage
grade and replace the product
model
For example 24V system change to
12V system, and replace the
corresponding controller
①
When the battery is over discharged, the battery indicator will be red and the load will be off all the
time before the voltage is more than the Low Voltage Reconnect Voltage (LVRV). In order to judge the
system is normal or not, firstly measuring the battery voltage whether is more than LVRV, if not,
restarting the controller to detect the load whether it is normal.
NOTE: The LVRV can be set, but it must pay more attention that it maybe damages the battery if
the LVRV is too low.
11. Disclaimer
This warranty does not apply under the following conditions:
Damage from improper use or use in an unsuitable environment.
PV or load current, voltage or power exceeding the rated value of controller.
The controller is working temperature exceed the limit working environment
temperature.
User disassembly or attempted repair the controller without permission.
The controller is damaged due to natural elements such as lighting.
The controller is damaged during transportation and shipment.
Any changes without prior notice! Version number
:
V1.2
10. Technical Specifications
Item Model
Tracer2606BPL
Tracer3906BPL
Tracer5206BPL
Tracer2610BPL
Tracer3910BPL
Tracer5210BPL
Nominal system voltage
12/24VDC Auto
#
Battery input voltage range
9
~
32VDC
Rated charge current
10A
15A
20A
10A
15A
20A
Rated charge power
130W/12V;260W/24V
195W/12V;390W/24V
260W/12V;520W/24V
130W/12V;260W/24V
195W/12V;390W/24V
260W/12V;520W/24V
Max. PV open circuit voltage
①
58V( at minimum operating environment temperature
)
46V( at 25
℃
environment temperature )
95V( at minimum operating environment temperature
)
92V( at 25
℃
environment temperature )
MPP Voltage range
( Battery 2V)
~
36V
( Battery 2V)
~
72V
Max. output current
3.3A
4.5A
6.6A
3.3A
4.5A
6.6A
Max. output power
100W
130W
200W
100W
130W
200W
Output voltage range
( Max. battery 2V)
~
58V
( Max. battery 2V)
~
80V
Load open circuit voltage
58V
80V
Load over voltage protection
63V
100V
Maximum output efficiency
96%
Output current control
accuracy
≤2%
Battery Type
Sealed / Gel / Flooded ; LiFePO4 / Li-NiCoMn / User
Equalize Charging Voltage
Sealed :14.6V/Gel
:
No / Flooded
:
14.8V
※
; No
Boost Charging Voltage
Sealed :14.4V/Gel
:
14.2V/Flooded
:
14.6V
※
; LiFePO4:14.6V/ Li-NiCoMn:12.51V / User:9-34V
Float Charging Voltage
Sealed/Gel/Flooded:13.8V
※
;
LiFePO4:14.4V / Li-NiCoMn:12.39V / User:9-34V
Low Voltage
Reconnect Voltage
Sealed/Gel/Flooded:12.6V
※
;
LiFePO4:12.0V / Li-NiCoMn:10.8V / User:9-34V
Low Voltage
Disconnect Voltage
Sealed/Gel/Flooded:11.1V
※
;
LiFePO4:10.6V / Li-NiCoMn:9.3V / User:9-34V
Self-consumption
≤15mA/12V;≤22mA/24V
Temperature compensation
coefficient
-3mV/
℃
/2V
#
Communication
RS485
Working environment
temperature
-40
℃~
+60
℃
Enclosure
IP67
Overall dimension
124×89×30mm
150×93.5×32.7mm
153×105×52.1mm
124×89×30mm
150×93.5×32.7mm
153×105×52.1mm
Mounting hole size
Φ3.5mm
Mounting dimension
88×76mm
120×83mm
120×94mm
88×76mm
120×83mm
120×94mm
Power cable
PV/BAT:14AWG(2.5mm
2
);LOAD:18AWG(1.0mm
2
)
PV/BAT:12AWG(4mm
2
);LOAD:16AWG(1.5mm
2
)
Net weight
0.54kg
0.73kg
1.18kg
0.54kg
0.73kg
1.18kg
※
The parameters are in 12V system at 25 ºC, please double the values in 24V system;
#
Lithium battery do not automatic identification system voltage and no temperature compensation coefficient.