Epever LS LPLI Series Manual Download Page 2

                         

                   

HUIZHOU EPEVER TECHNOLOGY CO., LTD.                          Tel

+86-10-82894896/8286-752-3889706                        Website

www.epever.com 

                                                     

3

                                                                                                                           

4

 

Timer3 
LED Rated Current Percentage 

2H 

50% 

0H 

0% 

00:00

—23:59H 

0

—100% 

Timer4/5 
LED Rated Current Percentage 

0H 

0% 

0H 

0% 

00:00

—23:59H 

0

—100% 

Timer6 
LED Rated Current Percentage 

0H 

0% 

2H 

100% 

00:00

—23:59H 

0

—100% 

    Modify the default value according to the user's requirement.

 

4) Time Control 

Control the load on/off time by setting the real-time clock. 

5) Intelligent Power Mode 

When the battery voltage goes lower than the "Reduce Power Start Voltage (adjustable)," 
the intelligent power reduction mode is enabled. The LED output current is automatically 
reduced in linear with the battery's voltage drop. When the battery voltage goes lower than 
the "Reduce Power End Voltage (adjustable)," the LED output current is 2% of the rated 
load current. The minimum percentage can be set to 1%). Also, when the battery voltage is 
higher  than  "Reduce  Power  Start  Voltage,"  the  controller  exits  the  intelligent  power 
reduction mode. 

 

CAUTION 

  In the mode of Light ON/OFF and Light ON/Timer, the load is turned on 

after a 1-minute delay

the delay time can be set. 

  The controller's real-time clock is an analog clock, valid at power-on and 

invalid after power-off. When using the time mode, the clock needs to be 
calibrated  by  handheld  devices.  Do  not  power  off  the  controller  after 
calibration. 

6. Setting Operation                                                                             

           

 
 
 
 
 
 
 
 
 
 
 
 

 

7. Protection                                                                                           

         

Protection 

Conditions 

Status 

PV Reverse Polarity 

When the battery is correctly connecting, 
the PV can be reversed. 

The controller is 
no damage

 

Battery Reverse 
Polarity

 

When the PV is not connected, or the 
connection is reversed, the battery can be 
reversed.

 

WARNING: Controller is damaged when 
the PV connection is correct, and the 
battery connection is reversed!

 

Battery Over Voltage 

The battery voltage reaches the OVD   

Stop charging 

Battery Over Discharge 

The battery voltage reaches the LVD   

Stop discharging 

Battery Overheating

 

The temperature sensor is higher than 65

 

Output is OFF 

The temperature sensor is less than 55

 

Output is ON 

Li-battery Low 
Temperature

 

The temperature sensor is less than the 
low-temperature value

 

Stop charging or 
discharge

 

The temperature sensor is higher than the 
low-temperature value

 

Begin charging 
or discharge

 

Load Short Circuit 

Load current ≥2.5 times rated current

  

In one short circuit, the output is OFF 5s; 
Two short circuits, the output is OFF 10s; 
Three short circuits, the output is OFF 15s; 
Four short circuits, the output is OFF 20s; 
Five short circuits, the output is OFF 25s; 
Six short circuits, the output is OFF 

Output is OFF 

Clear the fault: 

Restart the 
controller or 
wait for one 
night-day cycle 
(night time>3 
hours).

 

Load Open 
Circuit(Load over 
voltage) 

Max. load voltage

≥68V 

One open circuit, the output is OFF 5s; 
Two open circuits, the output is OFF 10s; 
Three open circuits, the output is OFF 15s; 
Four open circuits, the output is OFF 20s; 
Five open circuits, the output is OFF 25s; 
Six open circuits, the output is OFF 5s; 
Seven open circuits, the output is OFF 5s 

Output is OFF 
(Cycle to 
perform)

 

  If selecting a lithium battery, set the low-temperature value(LTV) according to the 

specification; otherwise, the lithium battery is damaged.

 

8. Troubleshooting                                                                                   

         

Faults 

Possible reasons 

Troubleshooting 

Charging LED 
indicator off during 
daytime when 
sunshine falls on PV 
modules properly 

PV   
array disconnection 

Confirm that PV and battery wire 
connections are correct and tight 

No LED indicator 

Min.9V can start up the 
controller. 

Measure the battery voltage with a 
multi-meter. Min.9V can start up the 
controller. 

Battery LED 
indicator green Fast 
Flashing 

Battery over voltage   

Disconnect the solar array and 

measure the battery voltage; 

Change the controller; 

  Change 

the battery 

Battery LED 
indicator red   

Battery   

over discharged

 

When the battery voltage is restored 
to or above setpoint (low voltage 
reconnect voltage), the load work 

Battery Status LED 
red indicator 
flashing 

Battery Overheating 

The controller automatically stops 
working. When the temperature is 
below 50 ºC, the controller resumes 

All the LED indicator 
flashing(battery red   

System voltage error 

Check whether the battery voltage 
matches the controller's working 

indicator flashing) 

voltage. Please change to a suitable 
battery or reset the working voltage 

Powering on   
normally, the load is 
off 

The connecting 

wires are error or 
virtual connection 

Load mode is wrong 

The controller does 

not match with the LED 
light. 

Output short circuit 

Check the connecting cables 

Check the load mode and 

parameter 

The voltage of the LED light source 

is not in the output voltage range of 
the controller 

Check the connecting cables and 

LED light source

 

The dimming 
function is invalid 

The controller does not 
match with the LED 
light source.

 

This 

product is a step-up 
current control; if the 
input voltage is lower 
than the rated voltage, 
it is not working. 

Replace the LED light   

Reduce system rated voltage 

grade, and replace the product model 
For example, switch the 24V system 
to the 12V system, and replace the 
corresponding controller. 

 

When the battery is over discharged, the battery indicator will be red. The load will be off 

all the time before the voltage is more than the Low Voltage Reconnect Voltage (LVRV). To 
judge the system is normal or not, firstly measuring the battery  voltage, whether  it  is more 
than LVRV; if not, restarting the controller to detect the load. 

 

WARNING 

The LVRV can be set, but it must be done carefully to avoid damaging the 
battery if the LVRV is set too low.

 

9. Technical Specifications                                                                   

 

◆ 

When selecting  a lithium battery, the controller cannot automatically recognize 
the nominal system voltage and has no temperature compensation. 

▼ 

The parameters are the 12V system at 25 ºC, double the values in the 24V system.

 

10. Disclaimer                                                                                             

 

 

This warranty does not apply under the following conditions: 

  Damage from improper use or use in an unsuitable environment. 

  PV or load current, voltage, or power is exceeding the rated value of the controller. 

  The controller's working temperature exceeds the limit working temperature. 

  User disassembly or attempted to repair the controller without permission. 

  The controller is damaged due to natural elements such as lighting. 

  The controller is damaged during transportation and shipment.     

                           

Any changes without prior notice!                Version number

V2.2

 

                  Models 

Item 

LS101240LPLI  LS101260LPLI 

LS102460LPLI 

LS2024120LPLI 

Nominal system 
voltage 

12VDC 

12/24VDC

 

Rated charge current 

10A 

10A 

10A 

20A 

Max. PV open circuit voltage 

30V 

50V 

Battery input voltage range 

9

16V 

9

32V 

Max. output power 

40W/12V 

60W/12V 

30W/12V 
60W/24V 

60W/12V 

120W/24V   

Max. output Current 

2.6A 

4.0A 

2.0A 

4.0A 

Output voltage range 

(Max. Battery V2V)

60V 

Load open circuit voltage 

60V 

Maximum output efficiency 

96% 

Output current 
control accuracy 

≤2% 

Battery Type 

Lead-acid battery: 

Sealed(default)/Gel/Flooded/User 

Lithium battery:

LiFePO4/Li-NiCoMn/User

 

L

e

a

d

-a

ci

d

 b

a

tte

ry

 

Equalization Voltage

 

Sealed:14.6V; Flooded:14.8V;User:9-17V 

Boost Voltage

 

Sealed:14.4V;Gel:14.2V;Flooded:14.6V;User:9-17V 

Float Voltage

 

Sealed/Gel/Flooded

13.8V; User

9-17V 

Reduce Power Start 
Voltage

 ▼

 

Sealed/Gel/Flooded

12.2V; User

9-17V 

Reduce Power End 
Voltage

 ▼

 

Sealed/Gel/Flooded

12.0V; User

9-17V 

Low Voltage   
Reconnect Voltage

 

Sealed/Gel/Flooded

12.6V; User

9-17V 

Low Voltage Disconnect 
Voltage

 

Sealed/Gel/Flooded

11.1V; User

9-17V 

L

ith

iu

m

 b

a

tte

ry

 

Boost Voltage

 

LiFePO4(4s):14.5V/Li-NiCoMn(3s):12.5V/User:9-17V 

Reduce Power Start 
Voltage

 ▼

 

LiFePO4(4s):12.8V/Li-NiCoMn(3s):12.2V/User:9-17V 

Reduce Power End 
Voltage

 ▼

 

LiFePO4(4s):12.0V/Li-NiCoMn(3s):10.5V/User:9-17V 

Low Voltage   
Reconnect Voltage

 

LiFePO4(4s):12.8V/Li-NiCoMn(3s):10.5V/User:9-17V 

Low Voltage Disconnect 
Voltage

 

LiFePO4(4s):11.1V/Li-NiCoMn(3s):9.3V/User:9-17V 

Self-consumption 

≤18mA(12V);≤23mA(24V) 

Charge Circuit Voltage Drop 

≤0.14V 

Com. way 

IR 

Com. distance of IR 

6m 

Working environment 
temperature 

-40

℃~

+55

 

Enclosure 

IP68(1.5m,72h) 

Overall dimension(mm) 

87x60x22.8  87x63x24.8 

87x63x24.8 

108.5x88x25.6 

Mounting dimension(mm) 

80 

80 

80 

100.5 

Mounting hole size(mm) 

Φ4 

Φ4 

Φ4 

Φ5 

Power cable 

PV/BAT:14AWG/2.5mm

2

 

LOAD: 18AWG/1.0mm

2

 

PV/BAT: 

12AWG/4.0mm

2

 

LOAD: 

18AWG/1.0mm

2

 

Net weight 

0.18kg 

0.21kg 

0.21kg 

0.40kg 

Figure 3 Setting Ways 

There  are  two  methods  to  check  and  set  the  controller

’s 

parameters:

 

1) IR Remote Controller

RC-10 

2) Super Parameter Programmer

—FC-01 

This method can realize one-key setting operation which is 
suitable for bulk quantity products setting or applied in the 
projects. 

NOTE: Please refer to the user manual of handheld device.

 

 

 

Reviews: