background image

                                   

HUIZHOU EPEVER TECHNOLOGY CO., LTD.                          Tel

+86-10-82894896/8286-752-3889706                        Website

www.epever.com

 

3

                                                            

4

 

6 Network connection                                                                           

 

one to one network connection 

 

 

one to more network connection 

Note:  EPEVER-RTU-4G-C  is  compatible  with  the  short-distance  LORA  wireless  transmission 

terminals. Up to 100 pcs LORA slave terminals can be connected through one LORA master. 

 

Working principle:

 

1) The controllers, inverters, or inverter/chargers transmit the feedback data 

to the EPEVER-RTU-4G-C. 

2) The EPEVER-RTU-4G-C transmits the received data to the cloud server 

for recording and processing via the 4G and Internet network. 

3)  According  to the  set  timing  task and  user terminal command, the cloud 

server 

continues 

to 

transmit 

the 

data 

and 

commands 

to 

EPEVER-RTU-4G-C. 

4) The EPEVER-RTU-4G-C transmits data and commands to the controllers, 

inverters, or inverter/chargers for execution. After finished, return to Step 

1)

 for a loop. 

7 Troubleshooting                                                                           

 

Faults 

Solutions 

Power 

indicator off 

1. Check 

whether 

to 

supply 

power 

to 

the 

EPEVER-RTU-4G-C. 

2. Check whether the indicators are damaged. 

3. If powered, check whether the positive and negative 

poles  of  the  power  supply  are  connected  inversely. 

The  input  terminal  of  the  EPEVER-RTU-4G-C  is 

equipped  with  anti-reverse  protection.  The  reverse 

connection  shall  not  cause  fatal  damage  to  the 

product.  However,  it  affects  the  normal  running 

before the correct connection is restored. 

WORK 

Indicator on 

solid 

After power is on, the WORK indicator will be on solid in 

60  seconds.  While  it  cannot  flash  after  60  seconds, 

please check below: 

1. Check whether the SIM card is inserted correctly. 

2. Confirm  the  SIM  card  has  activated  the  GPRS 

service. 

WORK  indicator  on  solid  again  after  running  for  a 

period, please check: 

1. Check whether the cloud server is normally running. 

2. Check whether the SIM card is loose or arrear. 

The product 

emits smoke 

with a 

pungent 

smell. 

The  actual  input  voltage  exceeds  the  rated  voltage  of 

the 

EPEVER-RTU-4G-C, 

causing 

the 

internal 

components  to  burn  out.  Don't  hesitate  to  contact  the 

supplier in time and send it to the manufacturer. 

The device 

can't register 

to the 

network. 

1. Check whether the SIM card is inserted correctly. 

2. Confirm  the  SIM  card  has  activated  the  GPRS 

service. 

3. Check  whether  the  input  power  is  sufficient.  The 

input voltage shall be DC8~64V or DC5V. 

Parameters 

can't be 

configured. 

1. Check whether the connection to the PC is correct. 

2. Check whether the serial port's selection is correct. 

8 Specifications                                                                           

           

            Model 

Parameter 

EPEVER-RTU-4G-C 

Input voltage 

DC8~64V or DC5V(Supply by the battery) 

Power consumption 

Peak emission voltage: 5V@200mA           

                  Idle voltage: 5V@40mA 

Working frequency 

2.4~2.4835GHz 

Configuration methods 

Cloud server, PC software, serial port 

command, SMS command 

Transmission protocol 

EPEVER IoT communication protocol V1.1 

Communication method 

RS485 

Communication    cable 

Included: RS485 to 5.08 

cable(CC-RJ45-5.08-150U) 

Optional: 3.81 to 5.08 

cable(CC-3.81-5.08-100U) 

Communication 

standard 

The male head standard in "Communication 

Interface Standard V-1.1" 

Baud 

9600Bps

115200bps, 8N1 

Antenna connector 

50Ω SMA (female head) 

Antenna gain 

2.5dBi ~ 5dBi 

Working temperature 

-40

85

 

Enclosure 

IP54 

Humidity range 

5

95%(NC.) 

Dimensions 

98Mm×86mm×24mm   

(Include the antenna and handle) 

Mounting dimension 

75mm / 75×25mm 

Mounting Holes 

Φ4 / Φ3 

Net Weight 

198g 

9 Disclaimers                                                                             

The warranty does not apply to the following conditions: 

  Damage caused by improper use or inappropriate environment. 

  The parameter setting exceeds the terminal's limit. 

  Damage caused by working temperature exceeds the rated range. 

  Unauthorized dismantling or attempted repair. 

  Damage caused by force majeure. 

  Damage occurred during transportation or handling. 

 

 

  Any changes without prior notice!        Version number: V1.1   

                                                               

 