background image

16

EN

Dear customer,

You have purchased a high quality technical de-

vice which will provide you with many years of 

enjoyable using. This infrared radiator was de-

signed and inspected according to the current 

European safety standards and manufactured 

at the factory in accordance with the quality 

management standard DIN EN ISO 9001:2015.

This detailed installation and operation manual 

has been prepared for your information. Please 

in particular thoroughly read the important no-

tice and the information on electrical connec-

tion.

First of all, check whether the infrared radiator  

has arrived at your site undamaged. Register 

transport damage claims immediately with the 

delivering transport company or please consult 

the supplier who provided the equipment to 

you.

 Caution!

Risk of fire by incorrect installation! Make 
sure to read the installation manual. Pay 
particular attention to the safety gaps and 
safety advices.

 Attention!

Dear customer,
According to the valid regulations, the  
electrical connection of the IR radiator 
and the control unit has to be carried out 
through the specialist of an authorized 
electric shop.
We would like to draw your attention that 
in case of a warranty claim, you are kindly 
requested to present a copy of the invoice 
of the executive electric shop.

 Attention!

Only the original spare parts may be used.
Any modification of the cables included in 
the delivery can lead to malfunctions and 
is not permitted.
Any unauthorized technical alteration 
makes the product warranty void.

Summary of Contents for Vitae Protect Compact

Page 1: ...Protect Compact D Montage und Gebrauchsanweisung Installation and operating instruction EN RU Infrarotw rmestrahler Infrared radiator Druck Nr print no 29345131 14 22 Technische nderungen vorbehalten...

Page 2: ...2 Deutsch 3 English 15 27...

Page 3: ...chnische Daten 7 Zubeh r optional 7 Interne Verdrahtung 7 Anschlussplan mit Steuerger t InfraTec Premium 8 Hinweis zum Elektroanschluss 9 Montage 10 12 Mindestabst nde 10 Einbaubeispiele 11 Recycling...

Page 4: ...unktion beeintr chtigen und ist nicht zul ssig Jegliche nicht autorisierte technische Ver nderung f hrt zum Verlust der Gew hr leistung Sehr geehrte Kundin sehr geehrter Kunde Sie haben ein hochwertig...

Page 5: ...angegeben Bitte fragen Sie Ihren Kabinenhersteller oder H ndler Allgemeine Sicherheitsbestimmungen F r die Regelung bzw Steuerung der Inf rarotstrahler ist ein geeignetes Steuerge r tzuverwenden Diese...

Page 6: ...e dass der Emitter im Infra rot W rmestrahler keinen mechanischen Belastungen St e Druck ausgesetzt wird Ist der Emitter einmal gebrochen was aber beim bestimmungsgem en Ge brauch unwahrscheinlich ist...

Page 7: ...modul mit Adapterkabel PVC 1 5 m 94 7811 IR Steckmodul mit Adapterkabel PVC 25 cm 94 7812 IR Verbindungsleitung SIHF 3 m 94 7813 Technische Daten Elektrischer Anschluss 230V N 50 Hz Leistung 350W 500W...

Page 8: ...ge im Steuerger t beachten Montage und Gebrauchsanweisung des Steuerger tes beachten 230 V 50 Hz 16A N N CTR L N L IR 1 IR 2 L LIGHT MAINS IR 3 Jumper KTY 10 5 L N N N L L S1 S2 Platine JP3 JP2 JP1 IR...

Page 9: ...eisung des Steuerger tes Falls Ihr Steuerger t mit der entsprechenden Leitung mit Anschlussbuchse ausgestattet ist wird der Strahler ber diese Steckverbindung verbunden Alternativ kann eine optional e...

Page 10: ...auf die ausreichende Hinterl ftung der Strahler um die berhitzung zu vermeiden Abb 4 Beachten Sie dass die Vitae Strahler eine sehr hoheW rmeintensit t besitzen Ein zu geringer Abstandf hrtzurschnelle...

Page 11: ...oben Achten sie darauf dass die Strahlerseite mit Kabelanschluss nach unten zeigen muss Beachten Sie die Sicherheitsabst nde wie in den Abb 4 5 8 un 9 angegeben Montage F hren Sie zuerst die R ckwand...

Page 12: ...egenst nde auf bzw direktvordemIR Emitterabgelegtwerden Brandgefahr ACHTUNG Der Strahler darf nicht im direkten Abs trahlbereicheinesanderenStrahlersmon tiert werden Risiko des Ger teschadens Einbaube...

Page 13: ...ycling Bitte diese Adresse zusammen mit der Montageanwei sung gut aufbewahren Damit wir Ihre Fragen schnell und kompetent beantwor ten k nnen geben Sie uns immer die auf dem Typen schild vermerkten Da...

Page 14: ...kte sind f r den St ckgut versand Palette konzipiert Wir weisen an dieser Stelle ausdr cklich darauf hin dass unsereVerpackungen nicht f r den Einzelversand per Paketdienst geeignet sind F r Sch den d...

Page 15: ...ries optional 19 Inner wiring scheme 19 Wiring diagram with control unit InfraTec Premium 20 Advice to electrical connections 21 Installation 22 24 Planning advice 22 Minimum distances Safety gaps 22...

Page 16: ...claims immediately with the delivering transport company or please consult the supplier who provided the equipment to you Caution Risk of fire by incorrect installation Make sure to read the installat...

Page 17: ...itable control unit to control theinfraredradiator Thecontrolunitmust bemountedinaccordancewiththeinstal lation instructions Attention Coveringtheinfraredradi ator causes a fire risk The installation...

Page 18: ...hanical stresses knocks pressure Risk of break age Although breakage is unlikely if it is used properly if the emitter should break re place it with a new one Caution fire risk in the case of a broken...

Page 19: ...mer module 1000 W 94 4954 IR plug adaptor with cable 1 5 m 94 7811 IR plug adaptor with cable 25 cm 94 7812 IR connection cable 3 m 94 7813 Technical data Voltage power supply 230V N 50 Hz Nominal pow...

Page 20: ...3 max 1500 W max 1500 W max IR Gesamtleistung 3500 W Connection example with control unit InfraTec Premium Max total load for all outputs of the InfraTec Premium control unit 3500 W Notice By connecti...

Page 21: ...in the control unit in stallation and operation manual If your control unit has the corresponding ca ble with plug connect the IR radiator using this plug Otherwise you can alternatively use the speci...

Page 22: ...refore vary Important note Do not expose the radiator to mechanical loads shocks pressure Risk of breakage ATTENTION When installing the IR radiator be sure that the cable connector is at the bottom M...

Page 23: ...and 9 Installation example and gaps Front view Fig 5 Dimensions in mm 200 795 167 785 60 ATTENTION Not suitable for horizontal installation and installation in the cabin ceiling Risk of fire due to he...

Page 24: ...zontal installation and installation in cabin ceiling is not allowed Risk of fire ATTENTION Do not install the IR radiator in direct heat range of another IR radiator Risk of damages due to overheatin...

Page 25: ...your questions quickly and compe tently please provide the information printed on the type shield including the model item no and serial no in all inquiries Equipment commissioning date ______________...

Page 26: ...roducts is designed for the ship ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall acce...

Page 27: ...27 RU 28 30 31 31 31 31 32 33 34 35 34 34 35 36 37 ASB 38...

Page 28: ...28 RU...

Page 29: ...29 RU 8 EU60335 2 53 VDE0700 53...

Page 30: ...30 RU...

Page 31: ...3 3 x 1 5 4 4x25 94 6596 1000 94 4954 1 5 94 7811 25 94 7812 3 94 7813 230 50 350 500 750 3 0 kg 795 x 200 x 60 0 8 10 20 C 50 C 70 EOS EmoTec IR InfaStyle InfraStyle i InfraTec Classic EOS Econ I1 In...

Page 32: ...16A N N CTR L N L IR 1 IR 2 L LIGHT MAINS IR 3 Jumper KTY 10 5 L N N N L L S1 S2 Platine JP3 JP2 JP1 IR Emitter 1 Power P1 IR Emitter 3 Power P3 max 1500 W max 1500 W max IR Gesamtleistung 3500 W Infr...

Page 33: ...33 RU 1 3 5 2 4 7 9 6 8 94 7812 2 2b 3 5 9 3 5 2b 1 3500 2 2b 94 7813 94 7811 94 7812 3500 5 9...

Page 34: ...34 RU 750 50 350 500 15 4 94 4954 7 4 4 4 8 3 3 min 4 cm min 7 cm min 4 cm Kabelanschluss muss unten sein min 4 cm...

Page 35: ...35 RU 5 4 5 8 9 5 200 795 167 785 60 6 7 7 6...

Page 36: ...36 RU 4 9 90 164 mm 167 mm 178 mm 45 mm 15 mm 8 164 mm 167 mm 178 mm Holzschutz 45 mm 40 mm 15 mm Mindestabstand Ger t muss hinterl ftet sein...

Page 37: ...37 RU EOS Saunatechnik GmbH Schneiderstriesch 1 35759 Driedorf Germany EOC 108811 928 7 495 66 55 192 8 800 1000 539 info eos sauna ru www eos sauna ru...

Page 38: ...38 RU ASB I II III IV V VI 24 www eos sauna com agb 08 2018...

Reviews: