background image

1

D

IP x4

Made in Germany

SteamTec Classic

Druck Nr. 29343783en    40.12

HD 7

GB

Assembly and operating instruction 

Summary of Contents for SteamTec Classic

Page 1: ...1 D IP x4 Made in Germany SteamTec Classic Druck Nr 29343783en 40 12 HD 7 GB Assembly and operating instruction...

Page 2: ...6 2 Final assembly 7 2 1 Dismantling the steam generator hood 7 2 2 Connecting to the water supply and drain 7 2 3 Steam connections 7 2 4 Connecting to the mains 7 Terminal diagram 8 2 5 Fitting the...

Page 3: ...3 GB 1000 300 Floor drain control room Connection for Steamfix Door Fresh air Cabin drain Plan Container for descaling li quid...

Page 4: ...r descaling Wiring cable feeds Terminal block X3 Steam pipe Fresh water supply pipe Pressure re lease valve Safety tempera ture limitation C o n t r o l PCB Steam generator Magnet val ve flush Drain f...

Page 5: ...L container for descaling liquid with level probe Owner s manual 1 Erecting the frame Complete the building according to the plans 1 1 Fresh water and dirty water The way in which the pipes for the f...

Page 6: ...eam pipe For all types of steam generator the steam pipe must always be either of copper or high quality stainless steel min 22 mm we recommend 35 mm in order to reduce the noise level and when it is...

Page 7: ...eam generator You can fix the steam exit either on the right hand side or below the steam generator Connect the Steamfix of the sauna heater to the pre installed 5 4 x 35 sleeve Important Notes The re...

Page 8: ...L N L N WM PE N N U V W WB Steamtec Classic Steuerger t control unit EMOTEC HCS 9003 EMOTEC HCS 9003 DB DL EMOTOUCH X3 400 V 3N AC 50 Hz 400 V 3N AC 50 Hz Saunaheater Powerunit Ventilator Cabin light...

Page 9: ...ing is started the steam generator must be disconnected from the mains By further questions and technical queries please contact your local EOS dealer 4 Operation The Steamtec Classic is controlled by...

Page 10: ...the flushing programme will come to an end The running time for the flushing programme is about 35 minutes The steam generator cannot be switched on during this time Check regularly if there is still...

Page 11: ...umber and model name with detailed description of the fault This guarantee covers defective parts and labour but not the defects caused by wear and tear In case of complaint please return the equipmen...

Page 12: ...ng articles or missing ac cessories He will discuss with you the individual case and try for immediate and customer friendly so lution For economic returns within Germany you will get an RMA number fr...