background image

1

D

Skytec

Druck Nr. 29493765en       28.12

GB

Assembly and operating instruction

Summary of Contents for Skytec

Page 1: ...1 D Skytec Druck Nr 29493765en 28 12 GB Assembly and operating instruction ...

Page 2: ...mbly of the control unit 3 Wall mounting 3 Operation 4 Save the appointed time 5 Technical data 5 Switching to coin box operation 6 Returning to timer operation 6 Connection diagram 7 Service Address 8 Guarantee 8 Handling procedures for return shipments RMA Details for all returns 9 ...

Page 3: ...ontrol unit from the electrical circuit i e flip all circuit breakers or the main circuit breaker during installation or repair In general there can only be one perma nent connection to the power supply net work to include a device which allows the unit to be disconnected from the power source with a contact distance of at least 3 mm from all terminals Assembly of the control unit Wall mounting To...

Page 4: ...the lower threaded holes Fig 4 Operation The radiator will be switched on by using the On Off switch 1 at the digital timer With the keys 3 and 4 you can select your favoured time 4 up 3 down After loose of time the digital timer of the ra diator switches off automatically Fig 4 Upper mounting hole Lower mounting holes Fig 5 1 2 3 4 15 ...

Page 5: ...time the bottons are blocked But the radiator can be switched off and on By switching on again the balance time elap ses After run of time the radiator cuts off and a new time can be set Fig 6 2 4 15 Fig 7 Technical data Rated voltage 230 V N AC 50 Hz Display 7 segmented LED display Maximum time of operation 30 minutes and 60 minutes respectively Environmental temperature 0 C to 40 C Storage tempe...

Page 6: ...rocedure When the coin box is not connected yet separate the appliance completely from the power supply While one person keeps the up and down buttons at the timer control panel simultaneously pressed see fig 8 the other person shall connect the radiator to the power supply When the coin box is already connected the radiator must not be disconnected from the power supply In this case proceed as fo...

Page 7: ...e carried out through the specia list of an authorized electric shop We would like to mention to the fact that in case of a warrenty claim you are kind ly requested to present a copy of the in voice of the executive electric shop Steuerplatine timer PCB Zeit time N L Anschluss connection InfraSky Kl 1 PE 1 2 4 3 6 5 Zeit time N L ...

Page 8: ... number and model name with detailed description of the fault This guarantee covers defective parts and labour but not the defects caused by wear and tear In case of complaint please return the equipment in its original packaging or other suitable packaging caution danger of transport damage to our service depart ment Always include the completed warranty certificate when returning equipment Possi...

Page 9: ...ong articles or missing ac cessories He will discuss with you the individual case and try for immediate and customer friendly so lution For economic returns within Germany you will get an RMA number from the manufacturer All returns have to be in the original packing of the goods with corre sponding accessories Please repack the goods to avoid damages In case of wrong delivery please do not use th...