EmoTouch 3 - Operating Instructions
23
Commissioning
Add-on modules or accessories are detected once the unit is switched on
(again) and their corresponding icons appear on the cabin image and in
the sub-menus.
Additional settings:
5.4 Basic settings,
4.2 Defining the light source manually
The control unit is set to inductive loads by the factory so that resistive
loads can also be controlled by the control panel. If required, the light out-
put can also be manually set to capacitive loads.
If light bulbs are used, the load for lighting must remain as an inductive
load.
The current setting is shown on the display.
NOTICE
Material damage
Lighting and the control unit could become damaged if non-dim-
mable light sources are installed. In this case, the warranty be-
comes void.
Work must only be performed by a trained technician from an
authorised company specialised in the trade.
Do not mount lights near rising steam.
The lighting must conform to protection class IP65 and be re-
sistant to ambient temperatures.
Connect only dimmable light sources.
For this setting, the lighting must be disconnected.
Display symbol Setting
Code
Inductive/resistive load (lighting for phase con-
trol),
if light bulbs are used.
Factory setting
8001
Capacitive load (lighting for phase control)
Electrical ballasts for phase-cut dimmer
8002
R,L
R,C