EOS ECON D3 Installation And Operating Instruction Download Page 6

General safety precautions

• 

This device can be used by children aged 
8 upwards and by persons with physical, 
sensory,  or  mental  disabilities,  or  who 
have  inadequate  experience  and  knowl-
edge if they are supervised or if they have 
received  adequate  instruction  in  how  to 
use the device safely and understand the 
associated  risks.  Children  may  not  play 
with  this  device.  Children  may  not  clean 
or carry out any user maintenance if un-
supervised. 

• 

Children  are  to  be  supervised  in  order  to 
make sure that they do not play with this 
device.

• 

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

Attention

:  It  is  forbidden  to  install 

the control box in a closed switch cabinet 
or behind a wooden panelling!

• 

The  electrical  installation  may  be  done 
only by a qualifi ed electrical technician.

• 

You must comply with the regulations of 
your power supply company and applica-
ble VDE regulations (DIN VDE 0100).

• 

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

 

WARNING

: Never attempt repairs or 

installations  yourself,  as  this  could  result 
in serious injury or death. Only a qualifi ed 
technician may remove the housing cover.

• 

Please note the dimensions in the assem-
bly instructions, especially when installing 
the temperature sensor. The temperature 
above the oven is critical for the temper-

ature  setting.  The  temperature  can  be 
held  within  operating  parameters  and 
a  minimal  temperature  gradient  inside 
the bench area of the sauna cabin can be 
achieved only if unit is assembled correct-
ly.

• 

The device may only be used as intended 
as a control unit for sauna ovens up to 9 
kW (up to 36 kW when combined with a 
contactor box).

• 

Completely  disconnect  the  control  unit 
from the electrical circuit, i.e. fl ip all circuit 
breakers or the main circuit breaker during 
each installation or repair. 

• 

Please  note  the  safety  and  installation 
information  from  the  sauna  oven  manu-
facturer.

• 

Always  heed  the  specifi cations  and  in-
structions of the cabin manufacturer, too.

• 

  If  control  units  with  remote  con-

trol  options*  are  used,  protection 
against  activation  when  the  heater  is 
covered is required. (e.g. cover protec-
tion Type 1-5 or S-Guard).

*Telecontrol = setting up, controlling or adjusting a 
unit by a command that can be given out of view 
of the unit by means of transfer media such as tele-
communication, audio technology or bus systems. 
(this also includes weekly timers)

6

GB

Summary of Contents for ECON D3

Page 1: ...1 GB IP x4 Made in Germany Sauna control unit Print no 29344726en 27 15 ECON D3 GB Installation and operating instruction...

Page 2: ...eater 13 Connecting a power extension unit LSG 13 Connecting the sauna lamp 13 Installation diagram 14 Terminal layout on the circuit board 14 Connection of sauna heaters up to 9 kW 15 Connection of s...

Page 3: ...re set timer 27 Activate the preselection time 28 Deactivate the preselection time 28 Extend the time setting for sauna time 29 Unit fuses 29 Error messages and troubleshooting 30 The device switch Sw...

Page 4: ...Rated voltage 400 V 3 N 50 Hz AC Power output max 9 kW resistive load AC1 operation Power extension up to 36 kW possibile with an optional LSG device Heating time limitation 6 h 12 h without limitati...

Page 5: ...ods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please observe th...

Page 6: ...e the dimensions in the assem blyinstructions especiallywheninstalling the temperature sensor The temperature above the oven is critical for the temper ature setting The temperature can be held within...

Page 7: ...ialist of an authorized electric shop We would like to draw your attention that in case of a warranty claim you are kindly requested to present a copy of the invoice of the executive electric shop Whe...

Page 8: ...hole The control unit is hooked onto this screw Therefore leave the screw out by approx 3 mm Fig 3 2 3 Hook the control unit onto the 3 mm protru ding screw in the upper mounting hole Insert the supp...

Page 9: ...east 3 5 cm deep according to the dimension in Fig 5 Insert the supplied rubber grommets into the openings at the rear wall of the housing and insert the connecting cables through these openings Place...

Page 10: ...to Fig 7 and 9 in larger cabins ac cording to Fig 8 and 9 Fig 7 housing red red sensor board sensor board Sensor white limiter white limiter Fig 10 Fig 8 Fig 9 2 Drill a hole in sauna ceiling panel to...

Page 11: ...and correct commissioning of the control unit the line for overtemperature protection must be checked for short circuits In order to do this disconnect one of the white cables in the sensor casing The...

Page 12: ...this case the sensor must be checked by a specialist and replaced if necessary At room temperature 20 C the sensor has approx 2 k resistance In order to keep on operating your sauna cabin despite the...

Page 13: ...installation instructions Run the silicone line through the ductwork to the power unit and connect it to the appropri ate terminals as directed in the wiring diagram Note In case there is no ductwork...

Page 14: ...N L LSG V1 S1 N Terminal layout on the main board Installation diagram 4 3 5 4 5 optional 400 V 3 N AC 50 Hz LSG ECON Connector for tempera ture sensor Jumper for heating time limitation Connection fo...

Page 15: ...or location of supervising staff by commercial sauna cabins with disabled heating time limitation 400 V 3 N AC 50 Hz max 100 W X1 ECON P max 9 kW U V W N L1 L2 L3 N V1 N S1 142 C KTY 10 5 Sensor Limi...

Page 16: ...operation The following pages provide the detailed explanation how to operate your control panel and make all necessary settings Operation elements Operating buttons Sauna cabin lighting Sauna heatin...

Page 17: ...ature figures will fill progressively Once the pre set temperature has been rea ched the bars will remain filled Interface in energy saving mode current time the clock symbol the light symbol when the...

Page 18: ...lighted in black can now be changed with the or the buttons All settings out of Stand by are confirmed by pressing MODE 3 s and are saved in the mem ory of the unit The blinking of the parameter ends...

Page 19: ...PL I RU 00 00 0 00 Time of day 12 00 DE GB NL PL I RU 00 00 12 00 Time of day 00 00 12 00 Time of day 00 00 12 15 Time of day 12 15 Life Guard 3 Sek 3 Sek 3 Sek 12 00 30 C 5 59 20 min Life Guard Tempe...

Page 20: ...12 00 DE GB NL PL I RU 12 00 DE GB NL PL I RU 12 00 DE GB NL PL I RU 00 00 0 00 Time of day 3 Sek 12 00 12 00 Time of day 12 00 30 C 5 59 Temperature Auto stop Start time MODE MODE MODE MODE 00 00 0...

Page 21: ...he child lock 12 00 30 C 5 59 Temperature Auto stop Start time If the child lock is activated the key symbol is visible in the top section of the display only the cabin lighting can be switched All ot...

Page 22: ...Life Guard Temperature Auto stop Start time The sauna heater is now heating normally wit hout Life Guard time Toactivatethefunction Life Guard 12 15 30 C 5 59 20 min Life Guard Temperature Auto stop...

Page 23: ...Start time 15 sec 12 00 85 C 5 59 Temperature Auto stop Start time 12 15 85 C 5 59 Temperature Auto stop Start time MODE MODE MODE 12 15 85 C 5 59 Temperature Auto stop Start time MODE MODE 12 15 85 C...

Page 24: ...ing for the pre set Life Guard time This setting can only be selected in Stand by when the function Life Guard is activated For instance you set 15 min time If you do not press the MODE button within...

Page 25: ...5 59 Temperature Auto stop Start time 12 00 30 C 5 59 Temperature Auto stop Start time 12 15 30 C 5 59 Temperature Auto stop Start time MODE 12 15 30 C 5 5 59 Temperature Auto stop Start time 12 15 30...

Page 26: ...30 Temperature Auto stop Start time 15 sek 12 15 30 C 5 3 30 Temperature Auto stop Start time 3 sec MODE 12 15 30 C 3 30 Temperature Auto stop Start time 12 00 30 C 3 30 Temperature Auto stop Start t...

Page 27: ...unit before the heating process begins Fire risk Please remember that a typical sauna cabin must heat up for approx 40 50 minutes in order to achieve a pleasant bathing climate If for example you wis...

Page 28: ...10 Temperature Auto stop Start time Deactivate the preselection time 12 15 30 C 5 59 17 10 Temperature Auto stop Start time to preselected time 12 15 30 C 5 59 17 10 Temperature Auto stop Start time...

Page 29: ...umper Jumper 6 00 hours heating time limitation factory default Jumper 12 00 hours heating time limitation Jumper no heating time limitation Such work must be carried out exclusively by an expert Prio...

Page 30: ...ne to the temperature sensor has a short circuit interrupted limiter circuit The temperature fuse 142 C has triggered or the line to the temperature fuse is interrupted Display Cause Remedy Arrange fo...

Page 31: ...s using this switch To turn the light on in the cabin while the unit is still disconnected push the left side of the ro cker to the second latch switch setting II Tomaketheunitreadyforoperation switch...

Page 32: ...el name with detailed description of the fault This guarantee covers defective parts and labour but not the defects caused by wear and tear In case of complaint please return the equip ment in its ori...

Page 33: ...ing of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall accept no liability for damage incurre...

Reviews: