NSTALLATION OF THE SAUNA OVEN AND CONTROL
UNIT MAY BE UNDERTAKEN ONLY BY AN AUTHORIZED
ELECTRICIAN. WITHOUT DOCUMENTATION OF SUCH
INSTALLATION, A WARRANTY IS FUNDAMENTALLY
INVALID.
PLEASE BE SURE TO NOTE!
Do not stack the stones in the stone
receptacle of the sauna oven in layers;
stack them loosely instead, leaving as
many spaces as possible to allow the hot
air to circulate.
$
Guarantee
The guarantee is taken over according to the legal
regulations at present.
Manufacturer’s warrenty
- The period of warrenty starts from the date of purchase
and lasts up to 2years for commercial use and 3 years
for private use.
- Always include the completed warrenty certificate when
returning equipment.
- The warrenty expires for appliances which have been
modified without manufacturer’s explicit agreement.
- Damages caused by incorrect operation or handling
through non-authorized persons are not covered under
the terms of warranty.
- In the event of a claim, please indicate the serial number
as well as the article code number and type name with
expressive description of the fault.
- This warrenty covers damaged parts but no defects due
to wear and tear.
In case of complaint please return the equipment in its
original packaging or other suitable packaging (caution:
danger of transport damage) to our service department.
Always include the completed warrenty certificate when
returning equipment.
Possible shipping costs arising from the transport to
and from point of repair cannot be borne by us.
Outside of Germany please contact your specialist
dealer in case of warranty claims. Direct warranty
processing with our service department is in this case
not possible.
Equipment start-up date:
Stamp and signature of the authorized electrician:
Instructions
Leakage current on sauna heaters
For the installation of sauna heaters, please pay
attention to the DIN VDE 0100 part 703 !
This norme states in the latest issue valid since
June 1992 under modifications paragraph (f); quote:
The demand for protection against leakage current
for equipment of protection class I alternatively to
protective low voltage has been dropped.
The EN 60335-1 DIN VDE 0700 part 1 of January
2001 states the following in paragraph 13; quote:
The leakage current may not exceed the following
values during operation:
- for stationary heaters of protection class I 0,75
mA; or 0,75 mA each kW input of the appliance,
depending on the higher value, at a maximum
value of 5 mA.
If the appliance is equipped with a protective device
for leakage current (ELCB), please pay attention to
the fact that no other electrical units will be protected
by this ELCB.
Under current manufacturing methods, it is not yet
possible to produce tubular heating elements for
sauna heaters which do not attract moisture on each
end from the surrounding air.
Therefore, should the ELCB be triggered during start-
up, the electrical installation must be checked.
It is also possible that moisture from the surrounding
air has been concentrated in the magnesium-oxide
filling in the heating elements during transport or
storage and is now causing the ELCB to be triggered.
In this case, the oven must be heated up under
supervision of an expert, during which the PE
conductor is not connected. After about 10 minutes,
when moisture has evaporated from the heating
elements , the oven must be reconnected to the PE
conductor!
If the sauna heater is not in use for a significant period
of time, we recommend running it every 6 weeks, so
as to avoid moisture concentrating in the heating
elements.
Installation of the sauna heater and control unit may
be undertaken only by an authorized electrician.
Without documentation of such installation, a
warranty is fundamentally invalid.
english