22
GB
Example of a properly connected sauna system
Caution! Always make
certain to include neutral
conductor N clamp
U V W N PE
2000W
2000W
2000W
400 V AC 3N
6 kW
U V W N PE
2500W
2500W
2500W
400 V AC 3N
7,5 kW
400 V AC 3N
PE
U V W N
1500W
1500W
1500W
1500W
1500W
1500W
9 kW
L1 L2 L3
N
Sensor
Limiter
S1
Saunasteuergerät
control unit
U V W WB WM N
400 V AC 3N
N U V W
max. 9 kW
Sensor
WB WM N
max. 3 kW
P
E
Wm
N
Wb
Wm
Wb
N
PE
Evaporator
If the unit is ope-
rated with a con-
troller without a
water shortage
circuit, the Wm
terminal is not
occupied.
Capacity
acc. DIN
Vaporicer
-capacity
-volume
Electrical.
Connection
Fuse
control
unit in A
Heater
dimensions
H/W/D cm
For cabin
size
Minimum
dimensions
of air
intake and
exhaust
vents
Weight
without
stones
without
package
Stone
fi lling
Connecting
cable main
- control unit
in mm²
Connecting
cable control
unit - heater
in mm²
Power
switch
gear
needed
For operation with
control units
6,0 kW
1,5 kW
5 l
3N AC
50 Hz
400 V
3 x 16
76*/ 45
/ 38
6 - 8 m³
35 x 4 cm
15,5 kg
15 kg
5 x 2,5²
5 x 1,5²
&
4 x 1,5²
no
ECON H1, H2, H3
EMOTEC H
EmoTouch II +
7,5 kW
7 - 10 m³
35 x 5 cm
16,0 kg
9,0 kW
9 - 14 m³
35 x 6 cm
16,5 kg
All cross sections of a line are minimum diameters in mm² (Copper line)
*)during 16 cm ground clearance