5
Mounting the sensor
1.
Install the sensor in the booth as shown
in the figure below.
19 cm
2. Drill a hole to lead
the cable through,
preferably through
the middle of one of
the wooden boards.
3. Route the sensor
lines through the
drilled hole and
connect.
hole
sensor housing
ceiling
Fcenter sensor
housing on middle
section
sensor line
terminals in the
control unit
4. Attach the lines for the limiter (white)
and the temperature sensor (red)
according to Illust. to the sensor board.
Then insert the sensor board into the
housing.
Ô
housing
red
red
sensor board
Sensor
white (Limiter)
white (Limiter)
Installation of the booth lighting
l
The booth lighting must correspond to
the protection type "splash-proof" and
be suitable for an ambient temperature
of 125°C.
l
The connection cable is to be fed
through the hole drilled beforehand, and
is to be connected to the booth lighting.
l
The booth lighting must always be
mounted as far as possible from the
positional spot of the infrared emitter,
and may not be directly beamed on.
Electrical installations
The electrical installation may
be only carried out by a
registered electrical contractor, while
adhering to the directives of the local
EVU and the VDE.
5. After you are finished installing and
have made sure the control unit is
functioning properly, check the line for
overheat shutoff protection for short
circuits. To do this, release one of the
white lines in the sensor housing. The
control unit's safety relay should now
fall, i.e. the heating circuit should now
be interrupted.
english