enware IFO6862 Manual Download Page 6

Each increment is 1 litre, adjustable from 2-5 litres, or 
from 2-3 litres for model 6832.

unit by turning it a quarter turn clockwise and then lifting 

 Flush volume 

 

 

button, cut away the catch on the lever arm as shown in 

so that the rear catch is installed facing forwards

10

Flush button

Removal of Flush Button and cistern cover

Servicing Cistern Components

This WC-unit is test approved according to NT VVS 120 

 

If necessary

See images 30 - 32. 

,       . 

24

23

30

31

Reinstalling

Maintenance advice and cleaning

Reinstall in reverse order. The screws for the cistern 
mounting must be tightened alternately to a maximum 
torque of 2.5 Nm as illustrated in image 35. The cover 
screw must be tightened to a maximum torque of 
1.0  Nm as illustrated in image 37.

32

33

WC units, bidets and wash basins have a glazed 
surface. Glazed surfaces are easy to keep clean and 
are resistant against most chemicals. Clean regularly to 
prevent cleaning problems. Use normal cleaning agents.

“Clean regularly to prevent cleaning problems.

 However, 

use hot water and soap and wipe dry with a cloth”.
This is because cleaning agents for porcelain are not 
intended for chrome parts/plastics and can risk cracking 

Cleaning utensils, which contain abrasive agents, such 
as wire wool and green scouring pads, must not be 
used. Strong acids, e.g. hydrochloric acid and sulphuric 
acid and strong alkalines, e.g. caustic soda should not 
be used. Dripping taps and running WC units must be 
repaired immediately.

For repair or to purchase spare parts, contact your local 
plumbing contractor or plumbing centre. For more inform-
ation, contact Enware.

If the toilet is subject to freezing temperatures, the WC 

0.3 - 0.4 litres of anti-freeze into the water trap and cover 

evaporation. 

Ifö Sign 6893, 6894

Note: Inlet Water Pressure Max. 500 kPa (AS 3500.1)

You get more free floor space with a wall-hung style WC unit. 

It facilitates easier cleaning of the bathroom floor.

Ifo Sign WC units are supplied with:

- Polished chrome flush button (IFO98303)

Optional:

Raised Chrome Button (IFO98308)

Remove the flush button, cover mounting and cover as

illustrated in images 16-22.

If the WC unit runs - first check that the outlet valve's

outlet seal washer is not damaged. If it is, replace the 

outlet washer (IFO96765), as illustrated in images 23-25.

Then check that the inlet valve closes correctly. If it does

not, replace the inlet valve (IFO96766) as illustrated in

images 26-28.

The lever arm to the inlet float is normally installed 

on the lower float setting for optimum water flow. This

setting can handle a water pressre of 10 bars. In the

event of the WC unit running at high water pressures,

the lever arm can be moved to the upper setting and

then handles a maximum water pressure of 12 bars. 

See image 29.

Summary of Contents for IFO6862

Page 1: ...h CAD drawings available from website All pans are to be fixed using high grade anti bacterial silicone of appropriate colour Where exposed mounting holes are provided 316 stainless steel screws are t...

Page 2: ...re com ifo Enware Australia Pty Limited 9 Endeavour Rd Caringbah NSW 2229 Australia Ph 02 8536 4000 Fax 02 8556 4055 360 415 860 355 95 190 40 650 420 120 100 40 Ifo Sign Toilet P Trap IFO6862 Version...

Page 3: ...95281 www ifosanitar com Assembly instructions If Sign SignFix SignArt 39 12 3 6832 6840 6860 6861 6862 6870 6872 6873 6893 6894 WC Unit 6860 6862 6870 6893 6840 6832 6861 6872 6873 6894...

Page 4: ...07 9 98308 10 98309 11 98310 12 98312 13 98313 14 90531 36 90533 34 90439 37 90437 38 32 90532 33 90536 35 90441 39 90442 91967 f r 6893 6894 6832 30 15 96767 16 96768 17 96765 96769 18 96782 18 98381...

Page 5: ...xed using a water proof floor mounting bracket IFO98015 The floor surface should be as flat and level as possible to ensure stability Fixing the toilet pan with only the silicone seal is not considere...

Page 6: ...must not be used Strong acids e g hydrochloric acid and sulphuric acid and strong alkalines e g caustic soda should not be used Dripping taps and running WC units must be repaired immediately For rep...

Page 7: ...0 24 Catch IFO91930 25 O ring frame 6832 IFO96783 26 Frame assembly IFO96772 Frame assembly 6832 IFO96781 27 Inner cistern with gasket IFO98951 Inner cistern with gasket 6832 IFO98960 28 Seal cistern...

Page 8: ...24 6 1 7 8...

Page 9: ...pan by the arm supports it is recommended that the toilet pan be fixed to the floor using stainless steel pan screws supplied IFO98381 together with a silicone bed or fixed using a water proof floor m...

Page 10: ...2 1 1 26 19 21 23 25 20 22 24 26...

Page 11: ...27 1 2 3 liter 8 liter 2 liter 5 liter Max 12 bar Max 10 bar 27 28 29 30 31 32...

Page 12: ...28 33 Max 2 5 Nm 1 3 2 4 34 35 Max 1 0 Nm 36 37...

Page 13: ...900 c c Sitsbulth l 155 460 95 400 455 650 40 190 102 40 120 6893 100 660 c c Sitsbulth l 155 325 760 355 230 20 102 75 290 150 100 105 max 95 min 40 6861 900 400 455 355 95 102 70 20 650 c c Sitsbult...

Page 14: ...rts save these instructions tu viegli piek t rezerves da m Installat r Installer Paigaldaja Instaliavo Uzst d t js Dato Date Kuup ev Data Datums If Sign Sign Fix 6860 6861 6862 6870 6872 6873 Part Cod...

Reviews: