11
13
12
14
GB
/
Make sure the surface of the tiles is clean,
dry and free from grease.
* IMPORTANT NOTE for toilets with Arm Supports (e.g. IFO98125): Due to the extra force applied to the toilet pan by the arm supports,
15
After pan is levelled, water is connected and pan is visually inspected for any leaks, install the rear cover to
plug the inspection hole. Apply silicone sealant underneath the base of the pan and around the perimeter
to create a strong bonding between the pan and the floor. Also apply silicone sealant around the rear cover
to create a thorough seal between the rear cover, pan and floor. Ensure no gap is left that can let any
moisture to get through inside the base of the pan.
If the WC unit is bonded / siliconed to the floor, the supplied blind cover plugs (IFO94752) must be used
in the screw holes on the WC unit, and sealed with silicone.
Do not use the WC before the silicone has cured.