INSTALLATION INSTRUCTIONS

1.  Place water chiller in desired position and adjust levelling feet so that the water 

chiller is stable and sitting level. 

 

Note: This appliance must be placed in a horizontal position. Ensure at least a 

50mm gap is left between the back of the unit and any wall for fan ventilation.

2.  Remove the front panel of the chiller unit by unscrewing the two fixing screws. Pull 

panel forward and slide down to remove the front panel. SEE 

IMAGE 1

 

IMPORTANT - CHILLER MUST BE DISCONNECTED FROM POWER SUPPLY BEFORE 

ACCESSING THE INSIDE OF THE CHILLER UNIT (Read CAUTION note on next page).

3.  From inside of the chiller unit, connect the 40mm bottle trap (supplied) to the 

waste connection located on the underside of the top tray. Connect DN40 DWV 

PVC drain pipe to the bottle trap. SEE 

IMAGE 2

4.  (Optional) Install a carbon filter (

DFS002F

- sold separately) inside the chiller unit. 

Cut or disconnect the 1/4” tube that feeds the bubbler (& carafe filler) and install 

the carbon filter in the line.

5.  Install a non-return isolating valve or a stop tap (not supplied) at the water supply 

as required. Flush all foreign matter from the water supply line, then connect water 

supply to the 1/2” BSP male inlet fitting located at the rear of unit.

6.  Install spout on the carafe filler. (See Carafe Filler Assembly Instructions below.)
7.  Turn the water supply on and purge the air from the stainless steel chilling tank by 

pressing the push button on the bubbler or lever on the carafe filler. Water may 

spit from the outlets during this procedure and care should be taken not to let 

water splash on walls and furniture. Placing a hand over the bubbler whilst purging 

the air will help prevent splashing. Allow the water to flow for 5 minutes, starting 

and stopping it frequently.

8.  Check all plumbing for leaks. Check the bottle trap and drain pipe connections for 

leaks. Replace the front panel to the chiller unit.

9.  Connect power cable to an electrical outlet. (Electrical connection - a flexible 2m 

service lead, 3 pin 10 AMP plug supplied to connect the chiller to a 240V 50Hz AC 

supply.) Turn power on. The refrigeration unit and the fans should start to activate.

10.  Once water is cooled and chiller function is checked, turn off the power and 

disconnect the power cable. Open the front panel and check all plumbing for leaks 

once again.

11.  Replace front panel of the water cooler and secure using screws provided. Connect 

power cable and turn power back on. Remove protective film on stainless models.

FRONT

PANEL

FIXING

SCREWS

IMAGE 1

CONNECT 

TO 40MM

WASTE

BOTTLE

TRAP

WATER

INLET

IMAGE 2

CARAFE FILLER ASSEMBLY INSTRUCTIONS

1.  Align the brass adjusting nut so that it sits crosswise. SEE 

IMAGE 3

2.  From the tapered end of the handle, start to slide the handle on to the nut, making 

sure the adjusting nut stays in the crosswise direction. SEE 

IMAGE 4

3.  Slide the handle all the way until it clicks into place.
4.  Insert spout into the spout hole. Screw the spout all the way in until it comes to a 

stop, then wind back to the desired spout position. SEE 

IMAGE 5

5.  Turn water supply on and check for leaks. 

SLIDE HANDLE ON 

FROM THIS SIDE

ADJUSTMENT NUT

POSITIONED 

CROSS-WISE

IMAGE 3

IMAGE 5

6.  Test the handle by pressing it down. If the 

handle is too tight or too loose, turn water 

supply off, go back to step 1 and adjust the 

nut up or down to achieve correct fit. If the 

handle is fit too tight, water may not shut 

off properly and may constantly run or drip 

from the spout.

  To loosen, unscrew nut (up). To tighten, 

screw the nut in (down). Go back to step 1.

IMAGE 4