Before proceeding with installation ensure all operating and dimensional specifications are suitable for the intended installation. 
Ensure all supply lines are flushed thoroughly to remove debris prior to the installation of this product. Strainers are recommended if 

debris is an ongoing problem. A pressure reduction valve may be required to comply with recommended maximum supply pressure.

Enware products must be installed in accordance with  AS/NZS 3500 – Plumbing and Drainage, the Plumbing Code of Australia as well as 

imposed Local and State / Territory Legislative requirements and the manufacturer’s instructions.

Enware tapware must be installed in accordance with the provisions of AS/NZS3500 and any 
relevant local regulations. Installations not complying with AS/NZS3500 may void the product and 
performance warranty provisions. The performance of Enware AS/NZS 3718 tapware, in many 
cases, exceeds the plumbing system design requirements of the Plumbing Code of Australia and 
AS/NZS 3500. 

Inlet Connection

3/8"x18 NPSM Female (BUB290)
1/2" BSP Male (BUB290B)

Recommended Working Pressure

100- 500 kPa

Flow Rate

2 l/minute (adjustable)

Recommended Temperature Range

5-30 °C

Technical Information

35

3/8 x 18 NPSM

70

40

70

90

BUB290

65

40

90

70

70

22  HOLE

1/2" BSP

BUB290B

technical data

installation compliance