trouble shooting
PROBLEM
CAUSE
RECTIFICATION
Flow stream is unsteady or
too low
Water supply conditions have
changed or are fluctuating
Incorrect flow adjustment
Check that water pressure is between
100kPa and 500kPa.
Remove the bubbler outlet and/or bottle
filler by removing the securing grubscrew
and pulling free.
Flush the bubbler thoroughly.
Disassemble the bubbler outlet and clean
any debris from the flow control, check
valve or gauze. Any damaged parts should
be replaced. Reassemble and test.
cleaning
Enware product should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water.
Do not use cleaning agents containing a corrosive acid, sourcing agent or solvent chemicals. Do not use cream
cleaners, as they are abrasive. Damage caused this way will not be covered by warranty.