background image

PROFILE-150 AXIAL EXTRACTOR FANS

Suitable for kitchen applications

INSTALLATION

IMPORTANT: before installing and wiring the unit, ensure that the mains supply is

disconnected.

PROFILE-150 should only be used in conjunction with fixed wiring.

Fig.1

1 – Grille

2 – Cable entry point

3 – Outlet

4 – Fixing screw for front cover

5 – Connection terminals

The PROFILE-150 is suitable for panel, ceiling or wall mounting (for wall mounting

applications using EnviroVent wall kit) (fig. 2).

Drill 160mm-diameter hole in chosen position in the panel, ceiling or wall. The hole for

the duct should be angled downwards to prevent rainwater running through the duct into

the unit.

Loosen the screw (4), which holds the grille in place (1) and remove grille.

Place the extractor against the internal wall or ceiling. For a wall mounted fan the

terminal block should be at the top. Mark the 4 screw hole positions. Drill, plug and

screw the extractor in position.

Check that the wall tube is not distorted and that the impeller turns freely.

This fan must be installed by a competent person. Complete electrical wiring of fan as

outlined in the Wiring Instructions below. Then refit the grille and tighten the screw (2).

4