PROFILE-100 AXIAL EXTRACTOR FANS 
Suitable for bathroom applications 

 

Thank  you  for  placing  your  confidence  in  EnviroVent  by  buying  this  product.  It 
has been manufactured following current technical safety regulations, production 
and  quality  standards  as  laid  down  by  the  international  Quality  Standard  ISO 
9001. Please read this instruction booklet carefully before installing or starting up 
the  product.  It  contains  important  information  on  personal  and  user  safety 
measures  to  be  followed  whilst  installing,  using  and  carrying  out  maintenance 
work  on  the  equipment.  Once  the  product  has  been  installed,  please  pass  this 
booklet to the end user. 
 
Check  that  the  product  is  in  perfect  condition  while  unpacking.  Any  fault  or 
damage  caused  in  origin  is  covered  by  the  EnviroVent  guarantee.  Please  make 
sure  that  the  product  corresponds  to  the  one  you  have  ordered  and  that  the 
details on the instruction plate fulfil your requirements. 
 
 

IMPORTANT: 

 

BE  SURE  TO  HAVE  READ  AND  UNDERSTOOD  THESE  INSTRUCTIONS 
BEFORE BEGINNING THE INSTALLATION PROCESS 
 

SAFETY AND RECOMMENDATIONS 

 

  All wiring must comply  with Building Regulations and the current  I.E.E. Wiring 

Regulations (BS7671) or the equivalent standards for your country. 
The final installation should be examined and tested by a competent person. 
This fan is IP44 rated. 

 

  Do not install near sources of heat in excess of 40°C. 

 

  Position  the  fan  at  the  furthest  distance  from  the  main  source  of  air 

replacement in the room in order to achieve maximum airflow performance. 

 

 

This  appliance  is  not  intended  for  use  by  young  children  or  infirm  persons 
unless  they  have  been  adequately  supervised  by  a  responsible  person  to 
ensure  that  they  can  use  the  appliance  safely.  Young  children  should  be 
supervised to ensure that they do not play with the appliance.

 

 
 

Summary of Contents for PROFILE-100

Page 1: ...PROFILE 100 Installation and Wiring Instructions ...

Page 2: ...make sure that the product corresponds to the one you have ordered and that the details on the instruction plate fulfil your requirements IMPORTANT BE SURE TO HAVE READ AND UNDERSTOOD THESE INSTRUCTIONS BEFORE BEGINNING THE INSTALLATION PROCESS SAFETY AND RECOMMENDATIONS All wiring must comply with Building Regulations and the current I E E Wiring Regulations BS7671 or the equivalent standards for...

Page 3: ...INSTALLATION PROFILE 100 Fig 1 1 4 3 2 5 Ø 105 mm ...

Page 4: ...INSTALLATION PROFILE 100 Fig 2 ...

Page 5: ...Fig 3 Fig 5 Fig 4 L N L N L N ...

Page 6: ...Fig 6 Fig 7 Fig 8 60 90 2 20 Hr 60 90 Hr 60 90 t min 2 20 t min 2 20 L N L N Fig 9 ...

Page 7: ...00mm The hole for the duct should be angled downwards to prevent rainwater running through the duct into the unit Loosen the screw 2 which holds the grille in place 1 and remove grille Place the extractor against the internal wall or ceiling For a wall mounted fan the terminal block should be at the bottom Mark the 4 screw hole positions Drill plug and screw the extractor in position Check that th...

Page 8: ...table timer The timer enables the fan to continue running for the selected period after the switch has been turned off Fig 5 Fan operating through an independent switch Fig 6 Fan operating through a light switch The desired run on time is selected by means of an adjuster positioned on the printed circuit board Fig 7 and is accessible once the grille 1 is removed To reduce the run on time turn anti...

Page 9: ...riod set on the timer after the light switch has been switched off ATTENTION When the humidity rises above the selected value the automatic option takes precedence over the manual and the unit cannot then be switched off using a switch Settings The fans are set to operate at 60 relative humidity and with 2 minutes run on time If the humidity in the room is lower than 60 the fan will not turn on If...

Page 10: ...riod The desired run on time is selected by means of an adjuster positioned on the printed circuit board fig 7 and accessible once the grille 1 has been removed To reduce the run on time turn anticlockwise min 1 minute To increase the run on time turn clockwise max 30 minutes CLEANING AND MAINTENANCE IMPORTANT DISCONNECT FROM THE MAINS SUPPLY BEFORE CARRYING OUT CLEANING OR MAINTENANCE To ensure o...

Page 11: ...e stated within this booklet In the event of any failure of the fan within two years of supply excluding only wilful or careless damage we will exchange the fan free of charge EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA Name and address of purchaser Model Date of purchase Dealer stamp ...

Page 12: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com info envirovent com Ref 9023007403 ...