POWER-170 & 250 CENTRIFUGAL EXTRACTOR FANS
Suitable for kitchen applications
DESCRIPTION
Suitable for both ceiling and wall installation, the POWER fans may be adapted to an
individual duct or to a communal ventilation system (Fig. 1).
The discharge port, situated at the side on the back of the extractor housing, enables it
to be installed anywhere on the wall or ceiling, even in inaccessible corners (Figs.2 & 3).
NOTE:
Pullcord models DP and HP should be mounted as shown in Fig.2.1 If
NOT
mounted as Fig.2.1, a support (not supplied ) must guide the pullcord so that it does not
rub the fan body. The pullcord (if used)
MUST
be easy to operate.
INSTALLATION
IMPORTANT:
ENSURE THAT THE MAINS SUPPLY IS SWITCHED OFF BEFORE
MAKING ELECTRICAL CONNECTIONS.
- Making use of the template enclosed, make a 100mm diameter round hole in the wall or
ceiling.
NOTE:
A 115mm dia. hole is required if a wall sleeve is utilised.
- Drill the holes for the screws and insert the respective plugs in them. Take the extractor fan
and withdraw the grille by pressing on the shoulders at the bottom (Fig.4).
- Remove retaining screw and lift off the terminal box cover (Fig.5).
-The installation may be made with the cable flush fitted by piercing either of the two notches
provided for this (Fig.6.1), or else with surface wiring, using the side cable inlet (Fig.6.2).
- Insert some 150mm of cable into the extractor housing and pass it through the cable
clamp.
- Fix the extractor to the wall. Arrange the foam rubber provided, around the discharge port
so that it fits closely to the duct. Secure the extractor housing to the wall by inserting and
tightening its screws.
WIRING
WARNING: This fan MUST NOT be earthed. It is double insulated. This fan MUST be
connected to a 220-240V 50Hz AC single phase mains supply.
There must be a double pole isolator in the installation with a contact separation of at least
3mm.
Connections depend upon the model of POWER fan being installed and the required mode
of operation.
Ensure that the mains supply is SWITCHED OFF before starting any wiring.
5