background image

POWER-170 & 250 CENTRIFUGAL EXTRACTOR FANS

Suitable for kitchen applications

DESCRIPTION

Suitable for both ceiling and wall installation, the POWER fans may be adapted to an
individual duct or to a communal ventilation system (Fig. 1).
The discharge port, situated at the side on the back of the extractor housing, enables it
to be installed anywhere on the wall or ceiling, even in inaccessible corners (Figs.2 & 3).

NOTE:

Pullcord models DP and HP should be mounted as shown in Fig.2.1 If

NOT

mounted as Fig.2.1, a support (not supplied ) must guide the pullcord so that it does not
rub the fan body. The pullcord (if used)

MUST

be easy to operate.

INSTALLATION

IMPORTANT:

ENSURE THAT THE MAINS SUPPLY IS SWITCHED OFF BEFORE

MAKING ELECTRICAL CONNECTIONS.

- Making use of the template enclosed, make a 100mm diameter round hole in the wall or

ceiling.

NOTE:

A 115mm dia. hole is required if a wall sleeve is utilised.

- Drill the holes for the screws and insert the respective plugs in them. Take the extractor fan

and withdraw the grille by pressing on the shoulders at the bottom (Fig.4).

- Remove retaining screw and lift off the terminal box cover (Fig.5).

-The installation may be made with the cable flush fitted by piercing either of the two notches

provided for this (Fig.6.1), or else with surface wiring, using the side cable inlet (Fig.6.2).

- Insert some 150mm of cable into the extractor housing and pass it through the cable

clamp.

- Fix the extractor to the wall. Arrange the foam rubber provided, around the discharge port

so that it fits closely to the duct. Secure the extractor housing to the wall by inserting and
tightening its screws.

WIRING

WARNING: This fan MUST NOT be earthed. It is double insulated. This fan MUST be
connected to a 220-240V 50Hz AC single phase mains supply.

There must be a double pole isolator in the installation with a contact separation of at least
3mm.
Connections depend upon the model of POWER fan being installed and the required mode
of operation.

Ensure that the mains supply is SWITCHED OFF before starting any wiring.

5

Summary of Contents for POWER-170

Page 1: ...POWER 170 250 Installation and Wiring Instructions POWER 170 250 Installation and Wiring Instructions...

Page 2: ......

Page 3: ...HESE INSTRUCTIONS BEFORE BEGINNING THE INSTALLATION PROCESS SAFETY AND RECOMMENDATIONS SITING A POWER 170 OR 250 All wiring must comply with Building Regulations and the current I E E Wiring Regulatio...

Page 4: ...INSTALLATION POWER 170 250 Fig 3 Fig 6 Fig 4 Fig 5 Fig 3 Fig 1 Fig 2...

Page 5: ...Fig 7 Fig 8 Fig 9 FAN FAN FAN Fig 10 ref 9019012300 RH ref 9019012300 RH...

Page 6: ...or the screws and insert the respective plugs in them Take the extractor fan and withdraw the grille by pressing on the shoulders at the bottom Fig 4 Remove retaining screw and lift off the terminal b...

Page 7: ...override The LED will NOT light under automatic humidity control even if the fan is running There is no permanent OFF position Use Fig 8 for wiring the manual override by the integral pullcord Use Fi...

Page 8: ...move any more parts than those mentioned as any tampering would automatically cancel the guarantee All regulations and requirements MUST be strictly followed to prevent hazards to life and property bo...

Page 9: ...ated within this booklet In the event of any failure of the fan within two years of supply excluding only wilful or careless damage we will exchange the fan free of charge EnviroVent Ltd EnviroVent Ho...

Page 10: ......

Page 11: ...eam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com info envirovent com Ref EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com i...

Reviews: