ECO dMEV Centrifugal Extract Fan

 

The  ECO  dMEV  extract  fan  range  is 

manufactured to the highest standards of 

production  and  quality  as  laid  down  by 

the  international  Quality  Standard  ISO 

9001.  All  components  have  been 

checked  and  every  one  of  the  final 

products  will  have  been  individually 

tested  at  the  end  of  the  manufacturing 

process. 

On receipt of the product we recommend 

that you to check the following: 

1- That it is the correct model. 

2- That the details on the rating label are 

those you require: voltage, frequency... 

The  installation  must  be  carried  out  in 

accordance  with  Building  Regulations 

and  the  current  I.E.E.  wiring  regulations 

(BS7671)  or  the  equivalent  standards  in 

force in your country. 

 

This appliance is not intended for use by 

young  children  or  infirm  persons  unless 

they have been adequately supervised by 

a responsible person to ensure that they 

can  use  the  appliance  safely.  Young 

children  should  be  supervised  to ensure 

that they do not play with the appliance 

 

Installation

 

IMPORTANT

:  Before  installing  and 

wiring  the  unit,  ensure  that  the  mains 

supply is disconnected. 

 

Fig. 1: 

1 : Front grille 

2:  Protection cover 

3:  Support  

 

4 : Connection terminals 

5 : Cable entry  

6 : Dip switches 

 

The  ECO  DMEV  is  suitable  for  wall  or 

ceiling  mounting  and  can  either  extract 

directly to the outside or through a ducted 

system (see Fig. 2). 

Make  a  Ø105  mm  hole  in  the  wall  or 

ceiling. 

If the unit is to be installed with ducting, 

use a standard Ø100 mm duct. 

Remove  the  front  grille  (1)  and  the 

protection cover (2). 

The  unit  can be mounted on the wall  or 

ceiling  using  the  4  raw  plugs  and  the 

screws provided. 

Ensure  that  there  are no obstructions to 

the  airflow  and  that  the  impeller  turns 

freely. 

Introduce  the  mains  cable  through  the 

cable entry (5) and fix it to the wall.  

Connect  the  electrical  wiring  as  set  out 

below  and  then  mount  the  protection 

cover and the front grille. 

 

Electrical connection

 

The  ECO  dMEV  is  an  extract  fan 

designed for a single phase supply, with 

voltage  and  frequency  as  indicated  on 

the rating plate of the unit. The units are 

manufactured  with  double  electrical 

insulation (Class II) and therefore they do 

not need an earth connection. 

 

The  electrical installation must  include a 

double  pole  switch  with  a  contact 

clearance of at least 3 mm. 

The electrical cable must enter the ECO 

dMEV through the cable entry (5). 

 

Once  the  cable  has  been  introduced 

proceed  using  the  electrical  wiring 

diagram  applicable  to  the  selected 

model. 

 

Operation 

The  ECO  dMEV  is  an  extract  fan 

designed  to  operate  continuously  at  low 

speed  and  constant  volume.  The 

constant  flow  setting  is  made  with  dip-

switches  placed  on  the  electronic  circuit 

board (Fig. 1): 

 

 

Summary of Contents for ECO DMEV SELV

Page 1: ... env1rovent ECO DMEV ECO DMEV SELV Instruction leaflet ...

Page 2: ...Fig 1 6 7 P2 P3 P1 SW1 1 SW1 2 SW1 3 SW1 4 SW1 5 1 2 3 4 5 ...

Page 3: ...Fig 2 ...

Page 4: ...Fig 3 L N J2 GND LS J1 LS N L 17V L N ECO dMEV 230Vac 50 60Hz CT 17 18 230Vac 50 60Hz 0 17V DC ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Page 5: ...Fig 4 J2 GND LS J1 LS N L 17V CT 17 18 230Vac 50 60Hz L N 230Vac 50 60Hz N L 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Page 6: ...Fig 5 J2 GND LS J1 LS N L 17V CT 17 18 230Vac 50 60Hz L N 230Vac 50 60Hz N L 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Page 7: ...Fig 6 L N J2 GND LS J1 LS N L 17V L N 230Vac 50 60Hz CT 17 18 230Vac 50 60Hz 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Page 8: ...Fig 8 Fig 7 P2 min P3 HR P2 min ...

Page 9: ...r wall or ceiling mounting and can either extract directly to the outside or through a ducted system see Fig 2 Make a Ø105 mm hole in the wall or ceiling If the unit is to be installed with ducting use a standard Ø100 mm duct Remove the front grille 1 and the protection cover 2 The unit can be mounted on the wall or ceiling using the 4 raw plugs and the screws provided Ensure that there are no obs...

Page 10: ...en turned off fig 5 Fig 4 shows how to connect the fan with timer through using the same switch as the lighting circuit to allow the fan to be boosted To set the timer turn the potentiometer P2 on the printed circuit board as fig 7 Manufacture setting 1 minute To reduce the run on time turn anticlockwise min 1 minute To increase the run on time turn clockwise max 30 minutes ECO dMEV HT Models prov...

Page 11: ...midity sensor has been set to maximum Change the setting The level of humidity in the room is below 60 RH If the fan always runs at boost The setting of the humidity sensor has been set to the minimum Change the setting The level of humidity in the room is above 90 RH ECO dMEV HTP ECO dMEV version similar to H model fitted with a manual pull cord to operate the boost when the humidity level is bel...

Page 12: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com info envirovent com Ref 9023025202 ...

Reviews: