Doc. No. MO-RKN-3062
Version 1.5: Sep. 08, 2010
30 (38)
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION RKN t2
Cooling system
Thermostat-controlled heat exchanger powered by 16 D-cell alkaline batteries and uses dry ice as coolant.
Max ice bunker capacity when using block ice
180 kg
(up to 50% less capacity if dry ice pellets are used)
397 lbs
Set temperature range
-20°C to +20°C
(-4°F to +68°F)
Temperature gradient of cargo
+5°C (+41°F)*
+/- 3°C (+/- 5.4°F)
+15°C (+59°F)*
+/- 5°C (+/- 9°F)
* Provided that the ambient temperature is between 5°C (9°F) to 25°C (45°F) higher than the set temperature.
Dimensions
External cube (volume)
4.8 cu.m
169.6 cu.ft
External dimensions (L x W x H)
2000 x 1535 x 1620 mm
78.7 x 60.4 x 63.8 in
Main loading space (L x W x H)
1415 x 1355 x 1360 mm
(please note free space requirements in front of the fan on next page)
55.7 x 53.3 x 53.5 in
Additional loading space (not right-angled) below dry ice bunker (L x W x H)
430 x 1355 x 860 mm
16.9 x 53.3 x 33.8 in
Door opening (L x H)
1415 x 1360 mm
53.5 x 55.7 in
Internal cube (volume) for refrigerated cargo
2.93 cu.m
103.4 cu.ft
Weight
Tare weight
265 kg**
584 lbs
Max gross weight (including dry ice)
1,588 kg
3,500 lbs
Max net weight
1,323 kg
2,916 lbs
** The tare weight may change due to repairs, see manufacturer's plate for correct weight.
Other information
Suitable for use on aircraft A300, A310, A330, A340, A380, B747, B767, B777, DC10, IL86, MD11, L1011
Forkliftable with a slot-height of 95 mm (3.7 in) and slot-width of 290 mm (11,4 in).