WHAT THE HEPA, ULTRAVIOLET LIGHT & 

PHOTO CATALYTIC AIR CLEANER DOES 

The  Console  HEPA,  Ultraviolet  Light  &  Photo 

Catalytic Air Cleaner has been designed to remove 

particulate  such  as  atmospheric  and  household 

dust, coal dust, insecticide dust, mites, pollen, mold 

spores,  fungi,  bacteria,  viruses,  pet  dander,  wood 

smoke,  cooking  smoke  and  grease,  tobacco  and 

cannabis smoke, and more.  
The  two  non-ozone  producing,  high  output 

Ultraviolet lamps provide germicidal sterilization for 

bacteria,  viruses,  mold  and  fungi  and  provide 

photons to the CinQuartz™ Media (Photo Catalytic 

Oxidation  Filter)  to  reduce  odors  and  Volatile 

Organic Compounds (VOC’s).  
A  Final  Filter  containing  a  mixture  of  Carbon  and 

Potassium  Permanganate  further  reduces  odors, 

light and non-organic gases. 

BENEFITS 

Helps provide relief from allergies, asthma, and

 

other respiratory illness.

Kills  or  inhibits  bacteria,  viruses,  mold,  fungi

 

and microbial growth.

Eliminates or reduces odors and gases emitted

 

from  air  fresheners,  carpets,  construction

 

materials,  glues,  household  cleaners,  paints,

 

varnishes, personal care products, press board

 

furniture,  cigarette  and  cannabis  smoke,  and

 

lots more.

housekeeping 

time 

and 

Helps 

reduce

 

redecorating costs.

Provides  a  healthier,  more  comfortable

environment, year-round.

HOW IT WORKS 

Millions  of  airborne  pollutants  are  carried  the  Air 

Cleaner by a powerful variable speed motor where 

they passes through a 5-stage filtration system. 
The  air  passes  through  a  pleated  Carbon  Prefilter 

to  remove  lint,  large  particles  and  heavy  weight 

gases  to  extend  the  life  of  the  HEPA  and  PCO 

filter. 
Smaller  particles  then  pass  through  a  long-life, 

99.97%  HEPA  (High  Efficiency  Particulate  Air) 

Media  Filter  which  captures  particles  0.3  micron 

(1/84,000 of an inch) and larger. The filter becomes 

more efficient as it gets dirtier with time. This HEPA 

filter  has  more  than  40  ft²  of  collection  surface 

area. 

The clean air passes through a reflection chamber 

where  two  High  Output  Ultraviolet  (C  band) 

Germicidal  Lamps  emit  powerful  UVC  light  rays 

which  are  designed  to  kill  or  inhibit  bacteria, 

viruses,  mold,  fungi  and  microbial  growth.  These 

are  non-ozone  producing  lamps.  The  Ultraviolet 

Light  is  also  used  to  activate  the  unique 

CinQuartz™ Media located above the UVC lamps. 
The  CinQuartz™  Photo  Catalytic  Oxidation  (PCO) 

Filter  is  a  Quartz  media  coated  with  nanoparticles 

of Titanium Dioxide (TiO

2

). The combined action of 

the  UVC  light  and  the  TiO

2

  decomposes  organic 

materials  into  basic  molecules  such  as  H

2

O  and 

CO

2

 and reduces odors and VOC’s as a result. 

Air then passes through a Final Filter containing a 

mixture  of  Carbon  and  Potassium  Permanganate 

pellets further reducing odors and light gases. 
Clean air is discharged back into the room. 

OPERATING INSTRUCTIONS 

Lean Air Cleaner on side panel and pull out of box.  

If your unit has any signs of damage, immediately 

contact  the  store  where  the  Air  Cleaner  was 

purchased. 
Keep  the  shipping  carton  and  packaging  in  case 

the need arises to store or transport the unit. 
Remove  all  p

a

ckaging  from  the  unit.  Choose  a 

suitable  location  to  allow  unobstructed  circulation 

from the front and top of the unit.  
The  Air  Cleaner  plugs  into  a  regular  outlet  at  the 

voltage shown on rating label. 
The Control Switch for the Air Cleaner is located on 

the  rear  of  the  unit.  To  turn  the  Air  Cleaner  on, 

rotate  the  Control  Switch  knob  clockwise.  This 

controls  the  power  to  the  Fan  and  to  the  UVC 

Lamps.    When  the    Control  Switch  is  turned  just 

past  the  click  position,  the  fan  is  on  high  speed. 

Rotating  the  Control  Switch  completely  clockwise 

reduces the fan speed to it’s lowest setting. When 

the  Control  Switch  is  turned  ON,  the  Indicator  on 

the rear of the unit will be illuminated.

 

The  Air  Cleaner  is  designed  to  run  continuously 

to provide clean, filtered air 24 hours a day. 

Running  the  Air  Cleaner  intermittently  will 

shorten the effective life of the lamps. 
Note:  Do  not  allow  the  cord  to  be  placed 

where it  may be walked on or allow anything to 

roll over it. 

WARNING 

This unit is designed to emit powerful ultraviolet radiation 

to  sterilize  microorganisms.  It  is  dangerous  to  come  in 

contact  with  or  look  at  the  light  from  this  unit. 

Always  turn  the  Air  Cleaner 

OFF

  and 

UNPLUG

  the 

unit  before opening panels or the lamp access door. 

WARNING 

The  air  cleaner  has  been  shipped  without  the  2  UVC 

lamps  installed.  The  filters  are  enclosed  in  plastic 

bags.  Before  running  the  unit  remove  the  plastic 

bags  and  discard 

safely. 

Install 

the 

lamps 

following  the  instructions  given  in  the  maintenance 

instructions.  Use  the  cotton  gloves  provided  when 

handling the lamps.  

Summary of Contents for EPFX P900

Page 1: ...gh Output Ultraviolet Germicidal Lamps CinQuartz Photo Catalytic Oxidation Filter removes unpleasant odors and Volatile Organic Compounds Carbon Potassium Permanganate Final Filter removes non organic...

Page 2: ...the unique CinQuartz Media located above the UVC lamps The CinQuartz Photo Catalytic Oxidation PCO Filter is a Quartz media coated with nanoparticles of Titanium Dioxide TiO2 The combined action of t...

Page 3: ...ants will shorten the life expectancy of the HEPA filter Note Handle the HEPA filter by the frame only The paper is fragile and a puncture or tear will reduce efficiency Replacing the UVC Lamps PCO Fi...

Page 4: ...es 4 WARNING Eye and skin damage may result from direct exposure to the light produced by the lamps used in this product Make sure the Air Cleaner is OFF and UNPLUGGED before the lamp access panel is...

Page 5: ...dangerous voltage or other hazards Refer all servicing to qualified personnel 6 Never push objects of any kind into the Air Cleaner through cabinet slots as they may touch dangerous voltage points or...

Page 6: ...andling of either defective parts or replacement parts LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are hereby limited in duration to the period for w...

Page 7: ......

Page 8: ...PLASTIC PACKAGING ON INSIDE FILTERS ENLEVER LA PELLICULE DE PLASTIQUE DES FILTRES REFER TO OWNER S MANUAL FOR INSTALLATION INSTRUCTIONS VOIR LES DIRECTIVES DANS LE MANUEL D INSTALLATION QUESTIONS DES...

Reviews: