flexible 12 inch intake duct, from the cold air return, 

to be attached. The 12 inch intake must be drawn 

from  the  cold  air  return  duct  at  a  location  that  will 

be  ahead  of  the  clean  exhaust  air,  that  will  be 

returned to the duct from the Air Cleaner. 

4.  A duct adapter and a length of 12 inch flexible hose 

or  duct  is  required  to  attach  between  the  12  inch 

intake  collar  and  the  existing  cold  air  return  duct.  

When  running  the  hose, make sure  that  there  are 

no  kinks  or  sharp  bends  that  will  impede  the  air 

flow  to  the  unit.    Secure  and  seal  the  hose  and 

connections to prevent air leakage. 

5.  The  8  inch  exhaust  collar  can  be  conveniently 

mounted on either side of the unit. A duct adapter 

and  a  length  of  8  inch  flexible  hose  or  duct  is 

required  to  attach  between  the  exhaust  collar  and 

the  existing  cold  air  return.  The  exhaust  hose 

should  be  attached  to  the return  air  duct,  close  to 

the furnace. The ideal location is low on the return 

air  boot  pointing  at  the  furnace.  To  prevent  air 

shear  inside the  duct,  it  is  recommended  that  you 

install a deflector inside the boot, so the discharged 

air  is  deflected  down  into  the  boot.  When  running 

the  hose,  make  sure  that  there  are  no  kinks  or 

sharp bends that will impede  the air  flow  from the 

unit.  Secure and seal the hose and connections to 

prevent air leakage. 

6.  It is  important to maintain some distance between 

the  intake  and  the  exhaust  openings  in  the  return 

air  duct.  Failure  to  do  this  may  result  in  short 

cycling  between  the  intake  and  the  clean  air 

discharge.  It  is  recommended  you  leave  10  feet 

between  the  intake  and  the  exhaust;  however,  as 

little as 6 feet will work effectively. If the distance is 

smaller  than  6  feet,  it  is  important  that  an  air 

deflector is installed in the duct. 

7.  If  outside  air  is  introduced  into  the  return  air  duct, 

either through a HRV (Heat Recovery Ventilator) or 

direct, it should be added to the system before the 

intake inlet to the Air Cleaner.  

OPERATING INSTRUCTIONS

 

The HEPA Air Cleaner is designed to run continuously 

to provide clean, filtered air 24 hours a day. The fan on 

the  heating/cooling  system,  to  which  the  HEPA  Air 

Cleaner  is  dependent  on  for  circulated  air,  should  be 

on ‘continuous’. 

Note:    If the system fan setting is on ‘automatic’, it is 

recommended  the  HEPA  Air  Cleaner  be  operated 

through  an  air  switch  or  relay  to  turn  the  Air  Cleaner 

off, when there is no system fan on. 

The  unit  plugs  into  a  regular  120  volt  outlet  and  is 

controlled  by  a  switch  located  on  the  rear  panel,  near 

the cord. 

Note:  Do not allow the cord to be placed where it 

may be walked on or allow anything to roll over it. 

The  door  must  be  secured  for  the  Air  Cleaner  to 

operate, as the door is interlocked for safety.  All filters 

must be in place for the unit to operate properly. 

MAINTENANCE

 

For efficient operation, the filters must be changed on a 

regular basis. If you notice a reduction in air flow from 

the system, check the filters.  
1.  To  access  the  filters,  turn  the  Air  Cleaner 

OFF

  at 

the switch and remove the front door. 

2.  Carefully remove filters to avoid spilling of collected 

contaminants.  Dispose  filters  in  a  plastic  bag  and 

discard with regular household trash. 

3.  Remove  plastic  from  new  filters  before  installing. 

Discard plastic safely. Take care not to damage the 

filters. 

4.  Date the replacement filters in the space provided. 

5.  Ensure that the direction arrow on filter is pointing 

toward the fan blade. 

6.  Use  genuine  replacement  filters  only.  Call  the 

original installer for parts. 

Note:    When  the  filters  are  new,  you  may  notice  a 

new  smell  from  the  system.  This  is  normal  and  will 

dissipate within a few days. 
Carbon  Prefilter  (Part  #W5-0810):

    This  must  be 

replaced  every  3  -  6  months  and  may  be  vacuumed 

between  changes.  Use  a  soft  brush  attachment  when 

cleaning. 

True  HEPA  Filter  (Part  #W5-0860-3):

  Replace every 

3-5 years. The life of this filter depends on the amount 

of  contaminants  in  the  air  and  the  frequency  in  which 

the  prefilter  has  been  changed.  Renovations  in  the 

home  that  create  wood,  drywall  dust  or  similar 

contaminants  will  shorten  the  life  expectancy  of  the 

HEPA filter. 

Note:    Handle  the  HEPA  filter  by  the  frame  only. 

The paper is fragile and a puncture or tear will reduce 

efficiency. 

VOC  After  Filters:

  The  2  inch  standard  or  heavy-

duty optional upgrade filters must be replaced every 6 - 

12 months. If there are heavy odors in the home from 

cooking,  smoking,  painting  or  other  sources,  the  filter 

may require changing more often. 

 

Replacement VOC After Filters (2 inch): 

Carbon Filter 

 

 

            Part #W5-0820 

 

Carbon/Potassium 

Permanganate Filter 

 

            Part #W5-0885 

WARNING  

Never use the unit without all of the filters in place.  

CAUTION  

Make sure to turn Air Cleaner 

OFF

 before performing 

any maintenance or removing any components.  

CAUTION  

The  new  HEPA  filter  may  be  tight  to  install  the  first 

time. Do not push from the center of filter. Apply even 

pressure at both corners.  

Summary of Contents for EPFX HEPA550-3

Page 1: ...pleasant odors and gases Heavy duty Carbon Potassium Permanganate VOC After Filter optional upgrade removes noxious odors and fumes emitted from household sources Easy to change filters Heavy gauge st...

Page 2: ...ticulate Air Filter which captures 99 97 of particles 0 3 micron 1 84 000 of an inch and larger This 6 inch filter has more than 188 ft of collection surface area Air is then drawn through a Carbon VO...

Page 3: ...the Air Cleaner off when there is no system fan on The unit plugs into a regular 120 volt outlet and is controlled by a switch located on the rear panel near the cord Note Do not allow the cord to be...

Page 4: ...SIBLE FOR 1 Normal maintenance as outlined in the Owner s Manual including cleaning and or replacement of filters 2 Damage or repairs needed as a consequence of any misapplication negligent handling i...

Page 5: ...ppl mentaires Le filtre terminal service dur de COV au charbon et au permanganate de potassium am lioration offerte en option limine les odeurs et les manations d sagr ables provenant de sources inter...

Page 6: ...nt ensuite un filtre durable HEPA filtre particules haute efficacit qui capture 99 97 des particules de 0 3 micron 1 84 000 de pouce et plus grandes Ce filtre de 6 pouces comporte plus de 188 pi de su...

Page 7: ...et elle est contr l e par un interrupteur plac sur le panneau arri re pr s du cordon Nota viter de placer le cordon un endroit o l on pourra marcher dessus ou des objets pourront tre plac s dessus La...

Page 8: ...la suite de toute mauvaise utilisation manutention n gligente entretien inad quat modification non autoris e ou fonctionnement inappropri 3 Les d g ts ou les r parations n cessit es la suite de toute...

Page 9: ......

Page 10: ...PLASTIC PACKAGING ON INSIDE FILTERS ENLEVER LA PELLICULE DE PLASTIQUE DES FILTRES REFER TO OWNER S MANUAL FOR INSTALLATION INSTRUCTIONS VOIR LES DIRECTIVES DANS LE MANUEL D INSTALLATION QUESTIONS DES...

Page 11: ......

Page 12: ...tape securing the ring to the enclosure Save the bag of screws attached to the intake ring Compress the ring until you can insert the ring flange into the opening in the enclosure Enlarge the ring to...

Reviews: