PUMP INSTALLATION

Risk of electrical shock.

Do not remove or alter

cord. Do not connect conduit to pump.
1. Only qualified personnel should install the pump and

associated control equipment.

2. Vent sewage tank according to local code.
3. Do not install pump in any location classified as haz-

ardous by National Electrical Code, ANSI/NFPA 70-1984.

4. These pumps are intended for permanent connection only.

Provide strain relief at control panel for power supply cord
connection to box. All control components must be UL
listed and suitable for end use application.

5. Do not pump flammable liquids, strong caustics, or strong

acids with this pump.

6. To prevent dropping pump, lower it by the drop pipe, not

by the cables. The electrical cables will not hold the pump
weight.

7. Discharge outlet is 1-1/4" NPT threaded. 

NOTICE:

If installing external check valve, hold discharge

with pipe wrench to prevent loosening discharge in shell.

8. If pump is to be operated with an open discharge, a dis-

charge valve

must be installed. Before startup, open this

valve about 1/3 open. Start pump. 

Slowly open valve until

the desired flow rate is reached. Final setting must be with-
in pump’s recommended operating range.

OPERATION

1. The pump must be submerged at all times during normal

operation. 

Do not run pump dry. 

2. Make sure that the float switches are set so that the pump

stops before the pump runs dry or breaks suction. If neces-
sary, adjust float switches to achieve this.

3. The motor bearings are lubricated internally. No mainte-

nance is required or possible on the pump.

T

o

tal Dynamic Head in F

eet (M)

Flow in USGPM (LPM)

0

(0)

10

(38)

20

(76)

30

(114)

0(0)

150(46)

200(61)

250(76)

100(30)

50(15)

40

(151)

PL-TE-10Plus

PL-TE-20Plus

PL-TE-30Plus

Figure 2: Performance in Feet of Head at Gallons per
Minute (M@LPM).

Table 1: Recommended Fusing Data

60 Hz/1 Phase 2-Wire Cable

Max

Locked

Fuse Size

Voltz/Hz/

Load

Rotor

Standard/

Model

HP

Phase

Amps

Amps

Dual Element

PL-TE-10Plus

1/2 115/60/1

11.0

30.0

15

PL-TE-20Plus

1/2 115/60/1

9.5

30.0

15

PL-TE-30Plus

1/2

115/60/1

9.5

30.0

15