ENVIROGARD Super Mosquito Important User Guidance Download Page 2

 

 

After  use  –  switch  off  the  equipment  by  reversing  the  above  procedure.  We  recommend  you 
disconnect the water supply at the inlet coupling and open drain valve (T) which is located just behind 
the water pressure guage (see adjacent picture).  This allows the unit to drain empty of water and is an 
absolute requirement during frosty weather.

 

 

  Drain Valve (T) 

In-use routine maintenance

 

 

The water supply passes through an in-line filter which will gradually block if your supply contains 
suspended  solids  (and  most  supplies  contain  some).  Periodically  unscrew  the  filter  housing 

hexagon nut, remove the filter mesh, clean in water and re-install. 

 

 

If  the  water  jet  is  uneven  clean  the  nozzles  (see  adjacent  picture)  -  unscrew  them  and  rinse  in 
water;  if  you  are  in  a  “hard  water”  area  (water  with  a  high  calcium  carbonate  content)  you  may 
need to soak the nozzles in an anti-scale solution; rinse in clean water before re-fitting. 

 

 

The “curly” power cable is subject to mechanical stress particularly when the oscillation function 
is selected; check for excessive wear or abrasion. 

 

If in doubt ask for advice from the supplying hire depot. 

 

Trouble-Shooting: 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

3.

 

 WARNINGS:  

Keep clear of fan inlet and outlet, never remove the fan inlet and outlet guards; do not attempt to open machinery 

casings.  The Super Mosquito discharges a plume of air and water mist at speed - don’t walk inside the plume within 2 metres 
of the discharge nozzle; always wear eye protection.  This machine works best with clean water - avoid using dirty water and 
water with high levels of suspended solids; do not use stagnant, or fetid water.  

 

The machine is capable of slow rotation / oscillation. Ensure nothing protrudes over the trailer – a minimum 1 metre clearance 
around the trailer platform is recommended; do not rest anything on the trailer that might obstruct the mist cannon’s rotation.  

 

 

If the machine sustains damage the equipment must be taken out of service and returned to the supplier. 

 

The Super Mosquito’s drawbar trailer is  equipped with a  50mm ball coupling and  supplementary break-away restraint – only   
connect  to  a  vehicle  with  a  corresponding  coupling.    The  trailer  is  un-braked;  when  decoupling  use  wheel  chocks  and  the 
trailer’s stabilising legs to prevent the trailer from rolling.  Keep trailer secured to towing vehicle by break-away restraint when 
disconnecting  the  tow  ball  coupling;  remove  the  supplementary  break-away  restraint  only  when  you  are  satisfied  that  the 
wheel chocks and/or stabilising legs have effectively secured the trailer. 
 

4.

 

 AFTER USE:

 on completion of work disconnect machine from power and water supply and open drain valve (T) ; 

always

 clean 

off the outside of the machine before returning to supplier.  Store in a frost-free environment when not in use.  Make sure the 
trailer is left secure with wheel chocks / stabilising legs deployed so that it cannot roll.

 

 

5.

 

 

TECHNICAL DATA:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR  MORE  INFORMATION  ABOUT  OUR  RANGE  OF  DUST  SUPPRESSION,  AIR  FILTRATION  AND 

VACUUM EQUIPMENT SEE OUR WEBSITE 

www.envirogard.co.uk

 OR CONTACT OUR DEPOTS 

 

 

 

 

 

 

 

 

 

 

 

 

        

 Page 2 of 2  Ref: EVGD 300118 

 

Linear reach 25 metres (still air); treated arc of rotation user selectable to 0, 40, 120 and 360 degrees. 
Arc rate of travel 360 degrees in 50 seconds; vertical tilt range user selectable from - 10  degrees to +60 degrees. 

 

Water supply required: minimum 2 bar (& max 10 bar); water consumption 15 litres / minute (standard mist nozzles) 

 

Overall Dimension (LxWxH mm) 3150 x 1390 x 2500, weight 540 kg (inclusive trailer); standard 50mm ball coupling. 

 

Required Site Power: Voltage 110v, Single phase 50 Hz; Current Draw (Running) 22 amps @ 110v. 

 

Noise level dBA: 75-78 @ 10m, 63-67 @ 25m, 57-61 @ 50m [highest level at fan intake] 
 

 

Problem

  

Cause / Solution 

 

Fan won’t start ? 

Reset  emergency-stop  button,  check  power  connection,  is  voltmeter  display 
showing 110v ?  Possible RCD tripped inside control cabinet. 

 

Fan tries to turn but supply trips to off ? 

Insufficient current / voltage to start fan. Minimise supply cable length, use heavier 
guage cable, check supply can accommodate start load. 

 

Mist Pump won’t start / Mist Cycles On-Off  Incoming  water  supply  insufficient  -  dry-run  protection  stops  mist  pump  when 

water pressure falls below 2 bar  -  increase incoming water supply pressure / flow. 

 

Mist Pump on but little or no water mist 

In line filter or nozzles blocked – clean. 

 

Oscillation / rotation function won’t start 

Controllers not yet initialised (requires up to 60 seconds). 

 

Machine suffers excess vibration ? 

Imbalanced fan due to debris build up on fan blade, or damage to fan blade. Stop 
machine & remove debris; in case of damage to blade contact supplier. 

 