background image

 
If at any time you have to replace a motor please follow the 
following procedure. 
1) 

Remove the (4) screws on the cooling air intake 
plate at the back of the machine. Remove the motor 
intake plate. 

2) 

Remove four Phillips screws from the motor plate. 

3) 

Unscrew the switch on the top of the machine and 
remove taking special precaution that the switch 
remains intact. 

4) 

Remove the motor plate with the (2) motors on it - 
Remove the defective motor and install the new 
motor making sure there is a motor gasket between 
the motor and motor plate. You can then screw the 
new motor in. 

5) 

Take the bottom motor wire of both motors and join 
them together. You then connect these wires to the 
white nylon terminal connector together. 

6) 

The single wire on the terminal board goes to 
number 1 (#1) on the switch. The wire on the 
bottom motor goes to number 2 (#2) on the switch 
and the top motor wire goes to number 3 (#3) on the 
switch. 

 

The white wire on the power cord goes to the wire 
on the terminal board that goes to #2 on the switch. 
The black wire on the power cord goes to the single 
wire on terminal that goes to the number 1 (#1) on 
the switch. You can now put the switch and plates 
back in place. 

 

Preventative Maintenance

 

 
The brushes should be changed every 400 operating hours. 
This procedure should become part of a preventative 
maintenance program. This eliminates potential problems 
with the commutator. 