background image

INTRODUCTION 

 

MAJOR COMPONENTS 

 
Cabinet 
The cabinet is fabricated out of satin coat mild steel and is 
painted via powder coating. The Enviroflex

 name etc. is 

silk screened over the powder-coated paint. 
 
The ESE101A-W Portable Smoke Extractor unit uses a high 
efficient washable filter. The operating life expectancy of the 
washable filter depends on the type of smoke being removed, 
the severity of the smoke, duty cycle and whether the precoat 
is being used after each cleaning. It is extremely difficult to 
pinpoint how many pounds of consumable wire or electrode 
that can be deposited before the filter has to be cleaned. This 
is  extremely  difficult  to  estimate,  as  there  are  too  many 
variables. 
 
To clean the high efficient filter: 
 
 

Please  note  the  suction  deteriorates  as  the  filter 
loads  up  with  contaminant.  This  deterioration  of 
suction  is  the  operator’s  indication  when  it  is  time 
to clean the filter. 

 
(1) 

Turn  off  the  Smoke  Extractor  and  pull  out  the 
electrical plug from the wall receptacle. 

 
(2) 

Unfasten  the  (2)  latches  located  at  the  front  of  the 
machine. Remove the spark trap. 

 
(3) 

Pull out the EF200A washable filter, which can be 
blown  out  using  a  low-pressure  air  nozzle.  You 
should  use  at  least  60  to  80  PSI  air  pressure.  You 
take the washable filter and turn it upside down and 
blow    it  from  the  outside  only  covering  the  entire 
media area. This should be repeated several times. 
You  utilize  the  gasket  on  the  front  of  the  filter  to 
eliminate  blowing  the  contaminant  all  over  the 
shop. 

 
(4) 

Place  the  clean  filter  back  into  the  cabinet  making 
sure  the  outer  gasket  comes  in  contact  with  the 
cabinet rim. 

 
(5) 

Before placing the spark trap on the unit you should 
shake  the  spark  trap  to  remove  any  heavy 
particulate  that  has  been  caught  inside  behind  the 
impinger plate. 

 
(6) 

Reinstall  the  spark  trap  in  the  cover  and  place  the 
spark trap over the front of the cabinet making sure 

that the cover is seated correctly on all edges of the 
cabinet. Tighten the (2) latch catches. 

 
(7) 

Plug the machine back into the wall receptacle and 
turn the unit on. You then take a cup of precoat and 
feed it gradually into the end of the 15 ft. hose such 
that  the  precoat  enters  the  hose  in  a  fine  mist.  Do 
not let the precoat go in all at once as it will enter 
the filter in a lump form whereas it should enter the 
filter  in  a  fine  mist  thus  precoating  the  entire 
surface  of  the  filter.  Please  note  the  filter  can  also 
be  cleaned  with  a  pressure  washer  as  the  filter  is 
moisture  resistant.  We  do  no  recommend  this 
process  unless  absolutely  necessary  (e.g.  oil  mist) 
as the filter has to be left overnight to dry. If it was 
wet  and  then  precoated  the  precoat  would  stick  to 
the wet areas and have a lumping effect. 

 
Charcoal Filters 
 
If you have purchased the (2) optional charcoal filters it is a 
very  easy  installation.    To  install  them  you  have  to  remove 
the  spark  trap then remove the EF200A filters. Install the 2 
charcoal modules by butting them up against the motor hole 
plates at back of the filter plate. Please note it is vital that the 
flat  portion  of  the  charcoal  cassette  is  facing  the  filters. 
Otherwise  the  air  does  not  get  a  chance  to  expand  before 
entering the motor and would only utilize a small portion of 
the  charcoal  the  size  of  the  motor  inlet  hole.  Re-install  the 
EF200A filter. Install the filter plate and the spark trap. 
 
The  charcoal  will  have  to  be  replaced  when  odors  can  be 
detected coming out of the louvers on the 2 sides of the unit. 
 
Electrical Service 
 
The  electric  motor  is  equipped  with  replaceable  brushes. 
Once the brushes become worn the motor will automatically 
stop,  thus  eliminating  any  potential  damage  to  the 
commutator.  To  replace  the  brushes  be  sure  that  the  power 
has  been  turned  off  and  the  power  cord  has  been  removed 
from the wall outlet. Unscrew the four screws located at the 
rear of the cabinet to allow access to the motors. Remove the 
protective  fan  cap  by  lifting  the  metal  clips,  which  are 
located  on  the  sides  of  the  cap.  Remove  the  hold  down 
screw,  which  secures  the  brush  in  place,  and  pull  off  the 
bayonet  connector  from  the  brush.  Remove  the  old  brush 
from  the  motor  and  install  the  new  brush  by  reversing  the 
above  procedure.  Replace  the  cap  and  screw  the  motor 
housing  plate  back  onto  the  back  of  the  cabinet.  The 
ESE101A-W unit is now ready to operate. 
 
If at any time you are unsure of any procedure, please do not 
hesitate to contact your nearest distributor. 

Reviews: