Wall Framing

Horizontal 
Termination

Wall Thimble
Fire Stop

Exhaust Pipe

Combustion Air
Outer Pipe

Elbow

Initial Installation

QUALIFIED INSTALLERS ONLY

h

oRizontaL

 t

eRmination

:

NOTES:

1. Horizontal pipes must not be level. For every 12” (305 mm) of horizontal travel (away 

from  the  stove),  there  should  be  at  least  ¼”  (6.4  mm)  of  vertical  travel.  Never  allow 

the vent to run downward, as this could cause high temperatures or even present the 

possibility of a fire.

2. The exterior of the horizontal 

vent termination must not be 

blocked or obstructed.

3. If the vent termination is not 

being attached to wood, the 

four wood screws provided 

should be replaced with material 

appropriate fasteners.

4. For buildings with vinyl siding, 

a  vinyl  standoff  should  be 

installed between the vent cap 

and the exterior wall. Attach 

the  vinyl  siding  standoff  to 

the horizontal termination. 

Note that the termination 

bolts  onto  the  flat  portion  of 

the  standoff,  providing  an  air 

space between the wall and 

the vent termination. The air 

gap prevents excessive heat 

from possibly melting the vinyl 

siding.

5. 

Horizontal pipes must be 

supported every 

3’ (914 mm)

Plumber’s all round strap will suffice.

6. Ensure venting clearances are maintained, see Page 26 for details.

Step 1.

  Set the fireplace in the desired location. Check to determine if wall studs will be in the way when 

the venting system is attached. If this is the case, the location of the fireplace may have to be 

adjusted or the venting may have to be offset. 

Step 2. 

Direct vent pipe sections are designed with special twist-lock connections. Dry fit the desired 

combination of pipe and elbows to the appliance adaptor.

Step 3. 

With the pipe in the correct position and attached to the fireplace, mark the wall for a 

10” 

(25.4 cm)

 x 

10” (25.4 cm)

 square hole (see Figure 31). The center of the hole should match 

the center line of the horizontal pipe. Cut and frame the hole in the exterior wall where the 

vent will be terminated. If the wall being penetrated is made of a non-combustible material (i.e. 

masonry or concrete) a 

7” (17.8 cm)

 hole is acceptable.

Figure 31.  Horizontal Vent Termination

Page 30

Summary of Contents for Q2GI

Page 1: ...ion and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html C 4001609 W A R R A N T Y R E G I S T R A T I O N e n v i r o c o...

Page 2: ...ur gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified...

Page 3: ...t be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 5...

Page 4: ...lass Door Removal 16 Burner Removal 16 Access Door 16 Fuel Conversion 17 Conversion Kit Installation 18 Initial Installation 20 Introduction 20 Placement and Framing 20 Framing Plate Installation 21 M...

Page 5: ...SI Z21 88 CSA 2 33 VENTED GAS FIREPLACE HEATERS CAN CGA 2 17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES This ENVIRO Q2GI Q2GID Fireplace Has been certified for use with either natural gas or propane see...

Page 6: ...never to be tampered with or removed All important information for your fireplace is on this label as well of the model specific serial number which you will need for warranty information Rating Labe...

Page 7: ...any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPE...

Page 8: ...ilot flame is burning normally and none of the burner ports are plugged Let the fireplace burn for roughly fifteen minutes and make adjustments as necessary The ideal flame will be blue at the base an...

Page 9: ...PLIANCE PRIOR TO REMOVING OR REINSERTING THE BATTERIES IN THE BATTERY HOLDER Blue LCD display UP DOWN Arrow Key ON OFF Key THERMOSTAT Key MODE Key Remote Control Operations Proflame 2 is a modular rem...

Page 10: ...radio frequency from the Transmitter to operate the appliance in accordance with the particular Proflame 2 system configuration The IFC has a red reset button at the front right corner that is used is...

Page 11: ...see Figure 8 Turn on the Appliance Press the ON OFF Key on the Transmitter The Transmitter display will show all active Icons on the screen A single beep from the Receiver will confirm reception of t...

Page 12: ...and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Key Figure 5 until...

Page 13: ...he First Time Figure 15 Remote Control Locked Figure 16 Low Battery Indicator WARNING Fire Hazard Can cause severe injury or death The Receiver causes ignition of the appliance The appliance can turn...

Page 14: ...a soft cloth Abrasive cleaners will damage the glass and painted surfaces Depending on the amount of use the glass should require cleaning no more than two or three times a season Do not clean the gla...

Page 15: ...oval The door will occasionally need to be removed for installation of media and cleaning of the Glass Step 1 First remove the safety screen by grabbing the top and bottom of the frame and lifting it...

Page 16: ...ure 21 Removing Access Door Access Door Step 1 Remove the burner as shown in the Maintenance and Service Burner Removal Step 2 Remove the Upper Air Diverter by removing 2 T 20 bolts Remove the Lower A...

Page 17: ...APPLIANCE WAS CONVERTED ON _______DD MM YYYY TO LPG PROPANE WITH KIT NO 50 3061 BY _______________________________________ NAME AND ADDRESS OF ORGANIZATION MAKING THIS CONVERSION WHICH ACCEPTS REPONSI...

Page 18: ...AN OPEN FLAME WHEN TESTING FOR LEAKS 12 Relight the pilot and confirm the flame properly covers the flame sensor see Figure 23 Should the pilot require adjustment turn the adjustment screw figure 36...

Page 19: ...tion guidelines which state the sea level rated input of Gas Designed Appliances installed at elevations above 2000 610 m feet is to be reduced 4 for each 1000 feet 305 m above sea level Refer also to...

Page 20: ...mm Minimum Framing Dimensions Depth 15 7 8 403mm Width 34 9 16 878mm Header Height 40 1016mm Chase Height Rear Vent N A N A Chase Height Top Vent 54 1372mm Gas Inlet Front 6 152mm Gas Inlet Height 1 1...

Page 21: ...tible material is only necessary over the fireplace opening and does not need to span the entire width of the framing plate A wood mantle can we placed over top of the non combustible as long as it st...

Page 22: ...opening and does not need to span the entire width of the framing plate In Front of Unit The Q2GI Q2GID can be placed on the floor if desired although it is recommended that it be raised aleast an in...

Page 23: ...tle 49 48 47 46 45 44 43 42 1 2 3 4 5 6 7 8 9 10 11 12 M A N T L E H E I G H T M A N T L E D E P T H Minimum Mantle Clearances 12 MANTLE 2 MANTLE Figure 27 Mantle Clearances Note Mantle height dimensi...

Page 24: ...vent and must be either correctly interlocked or fastened with three screws directly to the vent collar Check periodically that the vents are unrestricted Also ensure that all direct vent pipes have b...

Page 25: ...be opened C 12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distance...

Page 26: ...t Because the length of the vertical and horizontal sections dramatically affects the burning efficiency of the fireplace certain guidelines have been set in Initial Installation Allowable Co Axial Ve...

Page 27: ...VA WFS 4DT FS 4DFSH Wall Fire stop 46DVA FS 4CS 4DT FS 4DFSP 4DFS 4DSPFS Ceiling Fire stop 46DVA IS 4AS 4DT AIS 4DAIS12 AIS36 4DIS Attic Insulation Shield 46DVA WS 4WS 4DT WS B 4DWS 4DWS Wall strap su...

Page 28: ...vent pipe can not exceed 20 feet 6 1m and the total vent length can not exceed 40ft 12 2m Any combination of rise and run can be used as long as it lays within the shaded area a total of three 3 90 e...

Page 29: ...ION NOTES Do not bend flex vent over 90 degrees All horizontal runs should have a minimum 1 4 6mm rise per foot for optimal performance Do not allow the inner flex pipe to contact the outer pipe keep...

Page 30: ...ween the wall and the vent termination The air gap prevents excessive heat from possibly melting the vinyl siding 5 Horizontal pipes must be supported every 3 914 mm Plumber s all round strap will suf...

Page 31: ...the vent cap assembly to the outer wall of the vent pipe Bend any remaining portion of the strap back towards the vent cap Security Secure Vent uses a twist lock cap Step 5 Position the horizontal ven...

Page 32: ...the roof with roofing nails Use a non hardening sealant between the uphill edge of the flashing and the roof Insure the roofing material overlaps the top edge of the flashing Verify that you have at...

Page 33: ...be framed to 10 254 mm x 10 254 mm inside dimensions in the same manner as shown in Figure 35 Sangle de mur Bande de plombier connect sangle du mur Coudes 45 x2 4 Any occupied areas above the first fl...

Page 34: ...l manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water solution after...

Page 35: ...hould be plugged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug CAUTION When servicing controls label all wires prior to disconnection Wir...

Page 36: ...ll sit over these holes It is perfectly acceptable should a few pieces fall through upon installation NOTE Make sure the pilot flame is un obstructed and has a clear path the burner Keep the pilot are...

Page 37: ...indicator will blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in intervals Ad...

Page 38: ...the valve and pilot burner assembly orifice Pilot will not remain lit Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC board Check pilot for full flame imp...

Page 39: ...ll Mount 50 3028 11 Enviro Gel Decal 50 322 12 Control Cover w Decal 50 3022 13 Battery Holder 4 x AA 50 3027 14 Proflame 2 Integrated Fireplace Control IFC 50 3791 Proflame 2 IFC Wire Harness 0 584 9...

Page 40: ...9 7 10 12 13 16 3 11 14 6 4 1 5 8 15 2 17 17 18 20 19 Parts Diagram Page 40...

Page 41: ...Notes Page 41...

Page 42: ...Notes Page 42...

Page 43: ...reen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over...

Page 44: ...___________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy NA...

Reviews: