i
nStaLLation
:
1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the
desired area.
2. Install a 12 or 24 Volt Thermostat using an 18 x 2 gauge wire from the unit to the thermostat.
If the unit has been placed in the HI / LOW mode,
the unit will be taken to a low or idle setting when the
thermostat is not calling for heat. When the thermostat
calls for heat, the unit will go to the setting that is
displayed on the control board Heat Indicator.
26
Figure 39: Thermostat wire placement.
Follow the previous pages for through wall
installations. Ensure that vent pipe is properly
secured to wall using wall straps. Maintain
clearances to combustibles on vent pipe as
well as unit.