7
Operating Instructions
c
ontRoL
b
oaRd
F
unctionS
:
1. ON/OFF BUTTON:
Used to turn the unit ON and OFF manually.
2. FUEL TYPE BUTTON:
Used to switch between fuel type modes; Pellet (for all qualities of wood
FEED TRIM
ON/OFF
FUEL TYPE
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
PELLET
C-11256
MULTIFUEL
FEED TRIM
ON/OFF
FUEL TYPE
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
PELLET
C-11256
MULTIFUEL
1
2
3
4
5
6
7
pellets) and Multi-fuel (for all fuels including wood
pellets). When set on Multi-fuel it will run at a reduced
High Feed Rate with wood pellets.
NOTE:
Fuel Type
can only be changed when the unit is cold.
3. THERMOSTAT SWITCH:
Sets the unit’s control
mode; AUTO/OFF or HIGH/LOW (when using a
Thermostat or Timer) or MANUAL.
4. FUEL TYPE LIGHTS:
Shows the present Fuel Type
selected; Pellet is green and Multi-fuel is yellow. The
light flashes during start-up and stops flashing when
the 49
°
C (120
°
F) switch closes.
5. HEAT OUTPUT INDICATOR:
Shows the present
Heat Level output setting and the Feed Trim while it is
being adjusted.
6. HEAT LEVEL ADJUSTMENT BUTTONS:
When
pressed, will change the heat setting of the unit from
low to high. Arrow up button to increase heat and
arrow down to decrease heat.
7. FEED TRIM BUTTON:
Used in conjunction with the
Heat Level adjustment buttons to adjust the Feed Trim.
It can be increased by two (2) feed settings or it can be
decreased by two (2) feed settings. The Feed Trim can
only be adjusted one setting at a time.
This button can
also be used to “prime the auger system”.
Figure 2: Circuit Board Control Panel Decal
a
utomatic
S
aFety
F
eatuReS
oF
y
ouR
p
eLLet
S
tove
:
A. EXHAUST TEMPERATURE SWITCH: The stove will shut off when the fire goes out and the exhaust
temperature drops below 49
°
C (120
°
F).
B. HIGH LIMIT SAFETY SWITCH: If the temperature on the hopper reaches 93
°
C (200
°
F), the auger will
automatically stop, the stove will shut down, and it will display a #4 flash code. If this happens, call
your local dealer to reset the 93
°
C (200
°
F) high limit switch.
ALSO FIND THE REASONS WHY THE
UNIT OVERHEATED.
C. VACUUM SWITCH: If the combustion fan fails or the exhaust vent becomes blocked this switch will
stop the auger feed motor and the fire will go out.
o
peRating
y
ouR
p
eLLet
S
tove
:
NEVER OPERATE THE UNIT WITH THE DOOR, ASH DOOR, OR HOPPER LID OPEN.
CAUTION:
When operating during adverse weather, such as high winds or freezing rain, if the unit
exhibits dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust
outlet.
Summary of Contents for Maxx-M
Page 13: ...13...