20
Maintenance And Service
t
op
L
iGht
R
epLacement
:
A
DETAIL
A
SCALE
1 : 5
Figure 27: Light Deflector Removal
1. Disconnect electrical power to the unit.
2. Remove glass door (see
m
aIntenance
anD
s
erVIce
-
g
lass
D
oor
r
emoVal
).
3.
Remove light deflector (see Figure 27).
4. Remove the top light assembly by removing four (4)
screws using a 5/16 socket (see Figure 28).
5.
Grab the connectors firmly at the base to disconnect
them from the bulb assembly. Remove assembly
from unit then disconnect the ground wire.
A
DETAIL
A
SCALE
1 : 6
T-20 Screw (X2)
Light Cover
Top Light Assembly
Light Gasket
Light Retainer
6. Remove the light cover by removing the two (2) T-20
screws. If light gasket is damaged, contact your ENVIRO
dealer for replacement.
7. Replace the bulb or light assembly as necessary and
assemble back into unit.
Bulb Specifications: G9 Halogen, 25W, 120V
Enviro Part #: 50-4119
8. Reconnect electrical power.
Figure 28: Top Light Removal
Figure 29: Top Light Assembly