Initial Installation
QUALIFIED INSTALLERS ONLY
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can
result in carbon monoxide (CO) poisoning and possible death.
p
RepaRation
F
oR
i
nstaLLation
:
• Remove the packaging from the appliance, and check to make sure there is no damage. If damage is
found, please report it to both the carrier and your dealer as soon as possible.
• Before beginning, carefully check the glass door and the log set
• Locate a position where the flue system of the stove can be properly installed without damaging the
integrity of the building; e.g. cutting a wall or ceiling joist.
• Check stove and flue system clearance requirements.
• Locate the stove where it can be accessed by a gas supply line.
• Locate the stove in a large and open room that is centrally located in the house. This will optimize heat
circulation and comfort.
• As the stove is equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8 m) of
the stove.
• The flow of combustion and ventilation air must not be obstructed.
c
LeaRances
to
c
ombustibLes
:
A. Sidewall to unit
12 inches (30.5 cm)
B. Backwall to unit
4 inches (10.2 cm)
C. Corner to unit
2 inches (5.1 cm)
D. Combustibles to unit top 36 inches (91.4 cm)
E. Floor to unit
0 inches (0 cm)
F. Alcove maximum depth: 48 inches (121.9 cm)
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.
F
Lue
g
as
s
piLL
s
witch
:
NOTE:
This heater must be properly connected to a venting system. This heater is equipped with a vent
safety shutoff system designed to protect against improper venting of combustion products. This safety
switch is located on the rear of the appliance close to the drafthood relief opening.
If the switch trips more than once, the chimney should be inspected by a qualified service
technician for possible blockage or severe down draught conditions.
12"
(305 mm)
2"
(51 mm)
4"
(102 mm)
Figure 12: Clearances to combustibles.