background image

placing a jumper across the pins.  If the auger now cycles very quickly, test the dial-a-fire 
potentiometer.  If the auger did not cycle then replace the timing control module. 

To test the dial-a-fire potentiometer.  The potentiometer should have a range of 68K to 
approximately 850 K (

±

 10%), if the range is not close then replace the potentiometer. 

 
7. 

The dial-a-fire has no effect on the fire 

 

Make sure all connections to the timer control module are secure. 

Perform a resistance test to the dial-a-fire potentiometer, by placing the two test leads 
from a multimeter into the leads of the potentiometer.  The potentiometer should have a 
range of 68K to approximately 850 K (

±

 10%). 

 

  Potentiometer 

Readings: 

 

 

Full counter-clockwise (switched off) = open circuit, overload or Infinite resistance 

 

 

Low fire...................... 800 K to 900 K 

 

 

High fire..................... 68 K to 82 K 

 

If the range is not close or does not vary then replace the potentiometer. 
 
8. 

The stove will not shut down 

 

Check the connections to the 140

°

F (60

°

C) temperature sensor, start-up switch and the 

start-up timer against the wiring diagram. 

Check the 140

°

F (60

°

C) temperature sensor by removing one of the brown wires from 

the sensor.  The unit should shut down right away as long as the start button was not 
pressed within 15 minutes of this test.  If the stove shuts down within 15 minutes, 
replace the 140

°

F (60

°

C) sensor.  If the stove does not shut down within 15 minutes, test 

the switch. 

To test the switch, the stove must be cold.  Pull the plug, then plug the stove back in.  If 
the fails to start, Replace the switch. 

 
9. 

The stove keeps going out 

 

If the stove goes out and leaves fresh un-burned pellets or cigarette-like ashes in the 
burn pot liner, the fire is going out before the 140

°

F (60

°

C) temperature sensor shuts the 

stove off. 

Check to see that the slider is in the correct position. 

Turn the Dial-a-Fire up slightly (poor quality pellets will require slightly higher 
settings). 

 

If the stove goes out and there are partially burned pellets left in the burn pot liner, the 
stove shuts down due to a lack of air, exhaust temperature or power failure. 

Adjust the slider damper. 

Check to see if the stove needs a more complete cleaning. 

Turn the Dial-a-Fire up slightly (poor quality pellets will require slightly higher 
settings). 

Did the power go out? 

 

If the stove goes out and there are no pellets in the liner, the auger is stopping. 

See “The auger motor will not function normally” and “The exhaust blower will not 
function normally.” 

 

26

Summary of Contents for EF-III BAY I BIH

Page 1: ...1 SHERWOOD INDUSTRIES LTD 6782 OLDFIELD ROAD VICTORIA BRITISH COLUMBIA V8M 2A3 PELLET STOVE EF III BAY i OWNERS TECHNICAL MANUAL MODELS FS FPI and BIH...

Page 2: ...2 Vent Termination Requirements 12 Removing Your New Stove From It s Pallet 13 Masonry Fireplace Insert Installation 14 Assembling the Face Plate for the FPI BIH Models 15 Model BIH Recommended Framin...

Page 3: ...d on the left side of the stove It is advisable to clean the exhaust vent bi annually or every two tons of pellets The grounded electrical cord should be connected to a standard 115 volts 60 hertz ele...

Page 4: ...TOVE Since Sherwood Industries Ltd has no control over the quality of pellets that you use we assume no liability caused by the quality of wood pellets used P F I PELLET STANDARDS Fines 1 maximum thro...

Page 5: ...installed in Mobile Homes as well as Air Tight homes J GOLD BARS Please clean all fingerprints off of all gold parts before firing the unit each time Fingerprints etc can become etched into the gold...

Page 6: ...went out return to step number 2 and re light the stove DIAL A FIRE HEAT OUTPUT KNOB 6 Adjusting the blower speed control knob will vary the rate of airflow into the room by varying the speed of the c...

Page 7: ...de panel and tighten screws after placing the rod through the panel Screw the knob onto the slider OPERATION On the low heat output settings push the slider all the way in On the high heat output pull...

Page 8: ...and burn pot liner open the door using the door handle provided located on the left hand side of the stove swing the door open Lift the liner from the burn pot lift the burn pot from the firebox by g...

Page 9: ...ng it into one side panel then across into the other panel Screw rod in place Re install steel brick liner and screw in place Replace top baffle EXHAUST VENT Soot and Flyash Formation and Need for Rem...

Page 10: ...anger tubes and back into the room The units sealed system keeps the room air separate from the combustion air The convection fan controller controls this fan s speed 6 EXHAUST COMBUSTION BLOWER This...

Page 11: ...F 49 C N C TEMPERATURE SENSOR IGNITOR SHUT DOWN SENSOR This sensor mounted on the exhaust channel will turn the ignitor off when the exhaust temperature reaches 120 F 49 C 14 VACUUM SWITCH This safety...

Page 12: ...a wall to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure To keep exhaust from causing a nuisance or hazard from exposing people or s...

Page 13: ...eft and right side panels There are two wood screws that are holding the bottom of the stove to the pallet Remove the screws Close the side panels See PAGE 18 how to install the pedestal INSERT MODEL...

Page 14: ...nstalled with a continuous chimney liner of 3 or 4 diameter extending from the fireplace insert to the top of the chimney The liner must conform to type 3 requirements of CAN ULC S635 6 Recommended In...

Page 15: ...Insert each side panel anchor screw through the top panel into the corresponding side panel holes and tighten 3 Assemble the brass frame using the corner hardware and screws supplied in the face plate...

Page 16: ...IBLES This unit includes a 3 75 mm pedestal and surrounding faceplates The part of the unit behind the faceplate can be enclosed with combustible material Model BIH has 1 25 mm standoffs to establish...

Page 17: ...mm Mantle Hearth Mount 8 INCHES Combustible flooring underneath the unit and extending 6 INCHES 150 mm to the sides and front must be protected by a non combustible material ALCOVE DIMENSIONS Minimum...

Page 18: ...ation Remove the pedestal from the box Remove the ENVIROFIRE heater form the box Place the unit on its back making sure not to damage the wiring Back off the screws on the base install the pedestal ov...

Page 19: ...exhaust vent pipe to the exhaust pipe on the stove 10 All Joints in the vent system shall be fastened with 3 three screws Seal the connection with high temperature silicone 11 Push the stove straight...

Page 20: ...THROUGH WALL INSTALLATION 1 20...

Page 21: ...center of the fresh air intake pipe on the unit Match that center with the same point on the wall and cut a hole about 1 5 8 41 mm in diameter 5 Install the fresh air intake pipe 6 Install the tee wit...

Page 22: ...n finish it by performing the following 9 Install a tee with clean out on the outside of the house 10 Install PL vent upward from the tee Make sure that you install support brackets to keep the vent s...

Page 23: ...irtight homes or manufactured homes OUTSIDE FRESH AIR CONNECTIONS A Fresh air intake is strongly recommended Failure to install Intake air may result in improper combustion as well as the unit smoking...

Page 24: ...inged side panels held tight with two screws With the stove unplugged examine all connections Make sure they are firmly connected and that there are no exposed wires touching the stove except the chas...

Page 25: ...is operating Make sure the dial a fire is turned on Unplug the stove and open the side and back panels Check all the connections to the auger motor auger dial a fire vacuum sensor 200 F 93 C temperatu...

Page 26: ...own wires from the sensor The unit should shut down right away as long as the start button was not pressed within 15 minutes of this test If the stove shuts down within 15 minutes replace the 140 F 60...

Page 27: ...WIRING DIAGRAM 27...

Page 28: ...R HANDLE BOLT EF 129 EF3Bi STEEL BRICK LINER EF 036 AUGER TIMER CONTROL EF 133 EF3Bi RIGHT CABINET SIDE EF 037 EF3 POWER UP TIMER CONTROL EF 134 EF3Bi LEFT CABINET SIDE EF 041 GREEN LIGHT EF 141 HOPPE...

Page 29: ...002 AUGER TIMER CONTROL EF 036 START SWITCH EF 043 CONTROL PANEL W DECAL EF 053 HIGH LIMIT SENSOR 200 F 93 C MANUAL RESET EF 016 IGNITER TEMP SENSOR 120 F 49 C EF 015 FAN CONTROLLER EF 045 GREEN LIGHT...

Page 30: ...F 121 EF3Bi DOOR HANDLE EF 028 EF3Bi FRONT GRILL EF 123 FIREBOX CLEANING PORT COVERS EF 194 EF3Bi FS RIGHT CABINET SIDE EF 133 EF3Bi FPI SIDE RAILS R L EF 145 EF3Bi FS HOPPER SIDE RAIL EF 143 ASH PAN...

Page 31: ...mited warranty covers defects in materials and workmanship as long as the products has been installed according to the manual s instruction If the product is damaged or broken as a result of mishandli...

Reviews: