background image

Freestanding Direct 

Vent Kit With Coupler

 

KIT COMPONENTS:

Quantity Description

Quantity Description

1

Horizontal direct vent termination cap

1

Ø65⁄8” (17 cm) 90° elbow

2

Flue collar adapters (only one used)

4

Wire spacers

4

T-20 Torx screws

3

Decorative rings

1

Wall thimble

1

4 oz tube RTV silicone

1

Inside finish trim collar

20

9

/

16

” tech screws

1

5’  (190 cm) length of Ø4” (10 cm) double walled flex pipe

8

11⁄2” wood screws

2

24” (61 cm) section of Ø65⁄8” (17 cm) straight pipe

1

Vinyl siding deflector

Please  ensure  that  all  components  are  supplied  with  this  kit.  If  components  are  missing  or  have 

been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if 

components are missing or damaged.

INSTALLATION INSTRUCTIONS:

1. Decide on a location for the unit that will meet any or all local code requirements. Refer to the sections 

in your owner’s manual on where to locating your stove, planning your installation and clearances to 

combustibles.

2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing 

pipes are in the way of the venting system as it passes through the wall. If obstructions are found in 

the wall it may be required to adjust the location of the appliance.

3. Set the appliance in the desired location. Temporarily place a 24” (61 cm) section with the non-crimped 

end on the unit 

4. Install the 90° elbow onto the vertical pipe on the stove pointing in the 

direction that the vent will exit the structure. 

5. Project a level line from the center point of the elbow. Using this center 

point, scribe a 10” (25.4 cm) hole or square on the wall . Cut the hole 

out on both the interior and exterior wall surface. 

6. Frame the hole as shown in Figure 1. 
7.  Install  the  wall  thimble  and  secure  the  thimble  to  the  inner  wall 

surface.

8. With the appliance still in place install the 24” (61 cm) horizontal section 

on the elbow and let this section of pipe protrude through the exterior 

surface. Mark the pipe so that when it is cut it will be flush with the 

exterior wall.

9. Dismantle the outer pipe sections.

Figure 1

Please read and understand these instructions before installing. Failure to follow 

these instructions carefully could cause property damage or personal injury.

���

�������

���

�������

Reviews: