Dustkiller 1430

Voltage

Volt

220-240 V~

Frequency

Hertz

50/60 Hz

Rated power

Watt

1000

Max. power

Watt

1200

Air flow*

l/s

70

Negative pressure*

hPa/MG 265

Air flow**

l/s

40

Negative pressure**

hPa/SE 230

Noise level

dB(A)

69

Weight

kg

12,1

Dimensions (l x w x h)

cm

53 x 40 x 56 

* at the fan

** at the hose

Max. power on vacuum cleaners with plug socket: 2000 W

Mains connection cable on vacuum cleaners with plug socket: H05RR-F 3 x 1,5

Mains connection cable on ASBESTOS vacuum cleaners with plug socket: H07RR-F 3 x 1,5

13 Tests and approvals

Electro-technical tests must be carried out in accordance with the accident prevention regulations (BGV A3) and in accordance with 

DIN VDE 0701 Part 1 and Part 3. These tests are required in accordance with DIN VDE 0702 at regular intervals and after repair or modifi

-

cation.

The vacuum cleaners are successfully tested in accordance with IEC/EN 60335–2–69.

NOTE

Old equipment contains valuable materials which are designed 

for re-processing. 

The vacuum cleaners must not be thrown 

away in the normal household waste,

 but should be disposed 

of at a suitable proper collection system, e. g. via your communal 

disposal location.

Summary of Contents for DUSTKILLER

Page 1: ...1 DUSTKILLER Bedienungsanleitung Operating instructions Notice d utilisation 1430 H Asbest...

Page 2: ...2 D Original Bedienungsanleitung 09 GB Original operating instructions in German 18 F Instructions de service d origine allemande 27...

Page 3: ...3...

Page 4: ...4...

Page 5: ...5...

Page 6: ...6 BITTE UM BEACHTUNG WARTUNG UND REPARATUR VON INDUSTRIE STAUBSAUGERN DER KLASSE H ASBEST PLEASE NOTE MAINTENANCE AND REPAIRING OF INSUSTRIAL VACUUM CLEANERS OF THE CLASS H ASBESTOS 6...

Page 7: ...99 E Mail thomas opara asup info ASUP bietet nach Absprache mit Ihnen einen kostenpflichtigen Abhol und Auslieferungsservice mit eigenen Fahrzeugen an Bei Anlieferung durch Sie selbst muss gew hrleist...

Page 8: ...88 99 E Mail thomas opara asup info Following coordination with you ASUP provides a fee based pick up and drop off service with own vehicles If you drop off the equipment yourself you need to ensure t...

Page 9: ...in l Alkohol Verd nnung oder Gut das hei er als 60 C ist aufgesaugt werden Es besteht sonst Explosions und Brandgefahr l GEFAHR Reparaturen nur von Fachkr ften z B Kundendienst ausf hren lassen Nur Or...

Page 10: ...on Personen einschlie lich Kindern mit verringerten physischen sensorischen oder mentalen F higkeiten oder M ngel an Erfahrung und Wissen benutzt werden Kinder sind zu beaufsichtigen um sicherzustelle...

Page 11: ...versorgt werden 1 Anzeige und Bedienelemente W hlen Sie folgende Funktionen und Einstellungen 0 Sauger ausgeschaltet Steckdose spannungsf hrend I Sauger l uft Steckdose spannungsf hrend Automatische R...

Page 12: ...Der Sauger l uft immer mit max Drehzahl Netzstecker des Saugers in die Steckdose stecken Gew nschte Betriebsart am Schalter einstellen Sauger ist saugbereit Nach dem Saugen Schalter auf 0 stellen Saug...

Page 13: ...demAnsaugstutzen ziehen und Flansch verschlie en Sauggut gem den gesetzlichen Bestimmungen entsorgen 5 2 PE Entleer und Entsorgungsbeutel entsorgen PE Entleer und Entsorgungsbeutel Sauger einschalten...

Page 14: ...lten Reinigung vor der Demontage Vorsorge treffen f r rtliche gefilterte Zwangsentl ftung an der der Sauger demontiert wird Reinigung des Wartungsbereichs und geeignete pers nliche Schutzausr stung Vo...

Page 15: ...ugs in Ger te steckdose Netztstecker in Staubsauger Steckdose stecken Magnetventil der Druckluft Einschalt automatik verschmutzt Druckluft Einschaltautomatik mitAlkohol durch sp len PE Entleer und Ent...

Page 16: ...uch Anschlussleitung bei Saugern mit Steckdose H05VV F 3x1 5 H07RN F 3G 1 5 13 Pr fungen und Zulassungen Elektrotechnische Pr fungen sind nach den Vorschriften der Unfallverh tungsvorschrift BGVA3 und...

Page 17: ...5 EU EC Maschinenrichtlinie 2006 42 EG inklusive nderungen DIN EN 60335 1 VDE 0700 1 2012 10 EN 60335 1 2012 DIN EN 60335 1 Ber 1 VDE 700 1 Ber 1 2014 04 EN 60335 1 2012 AC 2014 EN 60335 1 2012 A11 20...

Page 18: ...ents explosive dusts liquids such as petrol oil alcohol diluents or materials hotter then 60 C 140 F Otherwise there will be danger of fire and explosions l DANGER Have repairs been made only by exper...

Page 19: ...by persons including children who have reduced physical sensory or metal capabilities or who are inexperienced or lack the knowledge of how to use the machine Children must be supervised to ensure th...

Page 20: ...and operating elements Select from the following functions and settings 0 Vacuum cleaner is switched off Plug socket current conducting I Vacuum cleaner is running Plug socket current conducting Auto...

Page 21: ...um cleaner into the plug socket Set the desired operating mode on the switch The vacuum cleaner is ready for suction After vacuum cleaning set the switch to 0 The vacuum cleaner is switched off Pull t...

Page 22: ...the suction spigot and close off the flange Dispose of the vacuumed up material in accordance with legal requirements 5 2 Dispose of the PE emptying and disposal bag PE emptying and disposal bag Swit...

Page 23: ...maintenance personnel or other Precautionary measures Suitable precautionary measures include Cleaning before dismantling Provide local filtered positive ventilation where the vacuum cleaner is to be...

Page 24: ...g socket Put the mains plug in the vacuum cleaner plug socket Solenoid valve of compressed air auto matic switch on contaminated Flush the compressed air automatic switch on with alcohol PE emptying a...

Page 25: ...m cleaners with plug socket H05RR F 3 x 1 5 Mains connection cable onASBESTOS vacuum cleaners with plug socket H07RR F 3 x 1 5 13 Tests and approvals Electro technical tests must be carried out in acc...

Page 26: ...65 EU EC Machinery Directive 2006 42 EU including amendments DIN EN 60335 1 VDE 0700 1 2012 10 EN 60335 1 2012 DIN EN 60335 1 Ber 1 VDE 700 1 Ber 1 2014 04 EN 60335 1 2012 AC 2014 EN 60335 1 2012 A11...

Page 27: ...sures ruptures le c ble d alimentation est d fectueux ou qu il est fissur ou poss de des traces d usure un d faut invisible est soup onn apr s une chute par exemple Garantir que des brosses lectriques...

Page 28: ...vail 1 mg m Les aspirateurs de la cat gorie M sont appropri s pour l aspiration de poussi res s ches non combustibles de liquides poussi res de bois non combustibles et de poussi res dangereuses avec...

Page 29: ...glages suivants 0 Aspirateur hors marche Prise conductrice de tension I Aspirateur en marche Prise conductrice de tension Fonction de vibration automatique d sactiv e A Disponibilit pour l automatism...

Page 30: ...eur de l aspirateur dans la prise R glezlemodedefonctionnementsouhait surlecommutateur L aspirateur est pr t au fonctionnement Ala fin de l aspiration commuter l interrupteur sur 0 L aspirateur est ho...

Page 31: ...chon Ouvrir les fermetures lat rales retirer la partie sup rieure Tirer prudemment la bride de la tubulure d aspiration et fermer la bride Eliminer les mati res aspir es de mani re conforme aux stipul...

Page 32: ...le porte ac cessoires Rassembler la fin du flexible d aspiration et le d but du flexible d aspiration Poser le flexible autour de l aspirateur et le coincer sur la poign e 9 Maintenance REMARQUE Toujo...

Page 33: ...R duction de la performance d aspi ration Filtre encrass Nettoyer Sac filtre non tiss plein Remplacer Cuve pleine Vider Buse tubes ou flexible colmat s Nettoyer Aspirateur ne d marre pas Fiche secteur...

Page 34: ...ssion acoustique dB A 69 Poids kg 12 1 Dimensions l x l x h cm 53 x 40 x 56 Au ventilateur au tuyau Puissance maximale sur les aspirateurs avec prise d alimentation 2 000 W C ble de connexion secteur...

Page 35: ...e UE EMC 2014 30 UE La directive ROHS 2011 65 UE Directive relative aux machines UE 2006 42 UE y compris ses amendements DIN EN 60335 1 VDE 0700 1 2012 10 EN 60335 1 2012 DIN EN 60335 1 Ber 1 VDE 700...

Page 36: ...klasse H sind geeignet f r dasAuf Absaugen von trockenen nicht brennbaren St uben krebserzeugenden und krankheitserregenden Partikeln sowie nicht brennbaren Fl ssigkeiten Holzst uben und gesundheitsge...

Page 37: ...h darf der Sauger nicht mehr im Wei bereich eingesetzt werden Ausnahmen sind nur zul ssig wenn der Sauger zwischenzeitlich von einer sach kundigen Person nach TRGS 519Nr 2 7 vollst ndig dekontaminiert...

Page 38: ...n conformity with TRGS 519 a for ENVIRO Dustkiller 1430 61 65 1 pour ENVIRO Dustkiller 1430 61 65 1 42 2 O GB Special Asbestos Sheet Caution This unit contains dust hazardous to health Only expert per...

Page 39: ...rmises si entre temps l aspirateur a t compl tement d contamin par un expert selon TRGS 519 n 2 7 Ce qui veut dire L aspirateur ne doit pas tre d contamin seulement ext rieurement mais aussi int rieur...

Page 40: ...asup info ASUP Store Berlin Am Oberhafen 12 13597 Berlin Spandau Tel 49 0 30 679 683 33 asup berlin asup info ASUP GmbH Hamburg Beckedorfer Bogen 10 21218 Seevetal Tel 49 0 4105 59888 0 info asup info...

Reviews: