19
Scenario #4
2. f
lame
s
ensor
s
horTed
or
d
isconnecTed
Switch to “OFF”
Wait 5 seconds
Switch to “ON”
Light blinks red three times means
sensor lead is disconnected/loose
Check continuity of
sensor wire
Switch the control module to “OFF”, wait 5 seconds, then switch to “ON”� If the diagnostic light
blinks red three times then goes into lockout mode (red/green flashing light), the sensor wire may
be loose or disconnected� Ensure the connection between the sensor wire and the control module�
See Figure 22 below for locations of wire connection to control module�
Figure 22: Control Module - Loose or Disconnected Sensor Wire
Natural Gas (NG)
Propane (LP)
Inlet Pressure
MAX: 7 inch W�C� (1�74 kPa)
MAX: 11 inch W�C� (2�74 kPa)
MIN: 4�5 inch W�C� (1�12 kPa)
MIN: 10�4 inch W�C� (2�59 kPa)
Manifold Pressure
MAX: 3�5 inch W�C� (0�87 kPa)
MAX: 10 inch W�C� (2�74 kPa)
MIN: 1�6 inch W�C� (0�39 kPa)
MIN: 6�4 inch W�C� (1�59 kPa)
Table 2:
Inlet & Manifold Pressures for NG and LP configurations