Enviro Berkeley-IPI Owner'S Manual Download Page 24

1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code.

In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code.

* These numbers are only estimates.

t  

A vent shall not terminate directly above a side walk or paved driveway that is located between two single family dwellings 

and it serves both dwellings.

Permitted only if verandah, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

 Clearances are in accordance with local installation codes and the requirements of the gas supplier.

NOTE: Venting terminals shall not be recessed into walls or siding.

Figure 33.  Vent Termination Restrictions, refer to Table 5.

Initial Installation

QUALIFIED INSTALLERS ONLY

v

ent

 t

eRmination

 R

estRictions

:

A

A

D E

L

B

C

F

B

B

B

J

M

K

G

H

I

Openable

Fixed

Closed

Openable

Fixed

Closed

Termination Cap

Air Supply Inlet

Gas Meter

G

G

Restriction Zone

(Termination not allowed)

N

O

Letter

Canadian Installation 

1

US Installation

2

Description

A

12 in (30 cm)

Clearance above grade, verandah, porch, deck, or balcony.

B

12 in  (30 cm) 

9 in  (23 cm)

Clearance from window or door that may be opened.

C

12 in (30 cm)*

Clearance from permanently closed window (to prevent 

condensation).

D

24 in (60 cm)*

Vertical clearance to ventilated soffit located above the 

terminal, within a horizontal distance of 2 ft (60 cm) from 

center line of terminal.

E

18 in (45 cm)

Clearance to unventilated soffit.

F

12 in (30 cm)*

Clearance to outside corner.

G

12 in (30 cm)*

Clearance to inside corner.

H

3 ft (91 cm) within a height of 

15 ft (4.5 m) above the meter/

regulator assembly

3 ft (91 cm) within a height of 

15 ft (4.5 m) above the meter/

regulator assembly*

Clearance to each side of center line extended above me-

ter/regulator assembly.

I

3 ft (91 cm)

3 ft (91 cm)*

Radial clearance around service regulator vent outlet.

J

12 in (30 cm)

9 in (23 cm)

Clearance to non-mechanical air supply inlet to building, or 

the combustion air inlet to any other appliance.

K

6 ft (1.83 m)

3 ft (91 cm) above if within 10 

ft (3 m) horizontally

Clearance to mechanical air supply inlet.

L

7 ft (2.13 m

)t

7 ft (2.13 m)*t

Clearance above paved sidewalk or paved driveway located 

on public property.

M

18 in / 45 cm

+

18 in / 45 cm

+

Clearance under verandah, porch, deck, or balcony.

N

12 in (30 cm)*

Clearance horizontally to any surface (such as an exterior 

wall) for vertical terminations.

O

12 in (30 cm)

Clearance above roof line for vertical terminations.

Table 5: Vent termination clearances.

24

Summary of Contents for Berkeley-IPI

Page 1: ...operty damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier Version Française www enviro com fr html 4001609 W A R R A N T Y R E G I S T R A T I O N e n v i r o c o m w a r r a n t y Berkeley IPI F R E e s t a n d i n g G a s F I R E P L A C E ...

Page 2: ...lumber or gas fitter when installed within the Commonwealth of Massachusetts Other Massachusetts code requirements Flexible connector must not be longer than 36in a shut off valve must be installed only direct vent sealed combustion products are approved for bedrooms bathrooms A carbon monoxide detector is required in all rooms containing gas fired direct vent appliances The fireplace damper must ...

Page 3: ...be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burners hav...

Page 4: ...g Decorative Surfaces 14 Cleaning the Glass 15 Cleaning the Firebox 15 Replacing the Glass 15 Flashout Guard 15 Cast Door Removal 16 Glass Door Removal 16 Burner Removal 17 Fuel Conversion 18 Initial Installation 20 Preparation for Installation 20 Clearance to Combustibles 20 Direct Vent 21 Venting Clearances 21 Approved Venting Parts 22 Horizontal Termination Minimum Vent 23 Vent Termination Rest...

Page 5: ...ATERS CAN CGA 2 17 M91 R2014 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 15 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO Berkeley Fireplace Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a listed wall thermostat IN USA see curr...

Page 6: ...erkeley Dimensions Rating Label Lighting Instructions Location The rating label and lighting instructions are located on a plate hanging on the back of of the unit 29 5 16 75 5 cm 4 5 8 11 7 cm 30 1 4 76 8 cm 31 3 8 79 7 cm 22 15 16 58 3 cm ...

Page 7: ...ance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Read the owner s manual including the section on Remote Control operation 3 Set the thermostat to the lowest setting 4 Turn off all electric power to the appliance 5 Do not attempt to light the pilot by hand 6 Wait five 5 ...

Page 8: ...opened or closed all the way and the correct flames cannot be attained turn off the gas and contact the dealer Warning Incorrect shutter adjustment may lead to improper combustion which is a safety hazard Contact the dealer if there is any concern about the venturi adjustment Figure 4 Air shutter adjustment lever 8 Less Air More Air Front Burner Rear Burner Operating Instructions Normal Sounds Dur...

Page 9: ...dout Figure 5 The Transmitter is powered by three 3 AAA type batteries A Mode Key is provided to Index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Figure 5 6 Figure 5 Proflame 2 Transmitter System Description The Proflame 2 Remote Control System consists of two 2 elements 1 Proflame 2 Transmitter 2 Integrated Fireplace Controller IFC and a...

Page 10: ...dance with the particular Proflame 2 system configuration The IFC has a red reset button at the front right corner that is used is to synchronize the Transmitter when using the for the first time or after the batteries have been replaced Figure 6 Proflame 2 Transmitter LCD Screen Figure 7 Integrated Fireplace Controller Low battery alarm Key Lock Room Temperature Dimmer ON Set Point Temperature Le...

Page 11: ... see Figure 8 Turn on the Appliance Press the ON OFF Key on the Transmitter The Transmitter display will show all active Icons on the screen A single beep from the IFC will confirm reception of the command and will commence to first ignite the pilot light followed by the main burner This should take about 10 seconds to complete Figure 8 Remote Control Display in Farenheit and Celcius Operating Ins...

Page 12: ...he actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the Thermostat Key Figure 5 until the word SMART appears to the right of the temperature bulb graphic Figure 11 To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen ...

Page 13: ...ion of the burner greatly reducing the heat output of the unit If you d like to have the fireplace on but would not like to have as much heat in the room you can turn off this function Press the Mode key of your remote repeatedly until the double flame icon is lit up refer to Figure 13 By pressing the up or down key turn the rear split valve to on or off The front flame on the burner will turn on ...

Page 14: ...e the number of changes to the room thermostat set point etc When the Transmitter batteries are low a Bettery Icon will appear on the LCD display of the Transmitter see Figure 18 before all battery power is lost When the batteries are replaced this icon will disappear IFC The life span of the IFC batteries depends on various factors during a prolonged power outage quality of the batteries used the...

Page 15: ...tion Log Set Installation section If any logs are damaged contact your nearest ENVIRO dealer Replacing the Glass The glass in the fireplace is a high temperature ceramic If the glass is damaged in any way a factory replacement is required see Parts List Wear gloves when handling damaged glass door assembly to prevent personal injury Do not operate with the glass front removed cracked or broken Rem...

Page 16: ... Figure 23 To replace the glass door simply reverse the above procedure Warning Do not touch or attempt to remove the glass door if the fireplace is not completely cold WARNING Never operate the fireplace with the glass door removed Glass Door Removal 16 Cast Top Cast Door The cast door on the Berkeley needs to be removed whenever access to the firebox is required First the Berkeley must be turned...

Page 17: ... 3 Place your hands in the air slots in the burners as shown in figure 25 then pull forward and lift up to dis engage the venturi tubes 4 Continue to lift up and rotate the burner approx 45 degrees as shown in Figure 26 and remove it from the firebox Take care not to damage the edges of the ceramic burner as it is fragile To re install the burner follow steps 1 4 in reverse When placing the burner...

Page 18: ... inspect all parts supplied with this conversion kit If any parts have been damaged or are missing contact your dealer distributor or courier company to have them replaced before starting this installation Maintenance And Service Conversion Kit Installation 1 Turn the unit off by pressing the ON OFF Key on the remote and shut off gas supply at the shut off valve upstream of the unit CAUTION The ga...

Page 19: ...y If converting to Propane use the supplied 56 orifice on the left In the USA The appliance may be installed at higher altitudes Please refer to your American Gas Association guidelines which state the sea level rated input of Gas Designed Appliances installed at elevations above 2000 610 m feet is to be reduced 4 for each 1000 feet 305 m above sea level Refer also to local authorities or codes wh...

Page 20: ... Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room that is centrally located in the house This will optimize heat circulation and comfort As the Berkeley is equipped with a convection fan ensure that an electrical outlet is within 6 ft 1 8 m of the stove The flow of combustion and ventilation ...

Page 21: ...nd arrangement Because the length of the vertical and horizontal sections dramatically affects the burning efficiency of the fireplace certain guidelines have been set in Initial Installation Allowable Vent Configurations Venting terminals can not be recessed into a wall or siding WARNING This gas appliance must not be connected to a chimney flue serving a separate solid burning appliances Figure ...

Page 22: ...ow 46DVA E90 4DE90 90 elbow 46DVA VSS VSS Vinyl siding standoff sheild 46DVA WT 4WT Wall thimble 46DVA SC SC Storm collar 46DVA WFS 4CS Fire stop 46DVA WS WS Wall strap support band 46DVA F6 4FA Flashing 0 12 to 7 12 roof pitch 46DVA F7 4FB Flashing 8 12 to 12 12 roof pitch 46DVA FF 4F Flat flashing 46DVA VCH SVT High wind vertical termination 46DVA HC HT High wind horizontal termination 46DVA KHC...

Page 23: ...p for the Berkeley A termination guard 50 3266 is required when the termination is within 7 2 13m of grade Figure 32 Minimum Vent Length Approved horizontal termination Approved through wall thimble 24 61 cm Minimum Length 12 30 5cm Maximum Length Termination Guard 50 3266 Only required when within 7 2 13m of grade 5 12 7cm Minimum Clearance Exterior Wall 23 ...

Page 24: ... may be opened C 12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft 60 cm from center line of terminal E 18 in 45 cm Clearance to unventilated soffit F 12 in 30 cm Clearance to outside corner G 12 in 30 cm Clearance to inside corner H 3 ft 91 cm within a h...

Page 25: ...umber of elbows is ideal as they tend to disrupt air movement Using 45 elbows is preferable to using 90 elbows Also a shorter vent system will perform better than a longer one The total length of horizontal vent pipe can not exceed 14 feet 4 27m with one elbow in the horizontal plane and the total vent length can not exceed 44ft 13 4m Any combination of rise and run can be used as long as it lays ...

Page 26: ...and Service section The firebox baffle must be removed next by removing the two front screws using a T20 screwdriver Figure 35 Next remove the restrictor set screws and install the restrictor at the desired setting refer to Figure 36 and tighten the set screws to hold it in place Refer to Figure 34 on the previous page for the correct restrictor setting to use in accordance with your installation ...

Page 27: ...The air gap prevents excessive heat from possibly melting the vinyl siding 5 Horizontal pipes must be supported every 3 feet 914 mm Plumber s all round strap will suffice 6 When running horizontal pipe clearances to combustibles must be maintained 1 inches 38 mm sides 1 inches 38 mm bottom and 2 inches 51 mm top Step 1 Set the fireplace in the desired location Check to determine if wall studs will...

Page 28: ...the vent termination should be pointing up Run a bead of non hardening mastic around the edges of the vent cap to make a seal with the wall Ensure the proper clearances to combustibles have been maintained Vertical Termination Step 1 Check the instructions for required clearances air spaces to combustibles when passing through ceilings walls roofs enclosures attic rafters or other nearby combustib...

Page 29: ...shing to the roof with roofing nails Use a non hardening sealant between the uphill edge of the flashing and the roof Insure the roofing material overlaps the top edge of the flashing Verify that you have at least the minimum clearance to combustibles at the roof line STEP 8 Continue to add pipe sections until the height of the vent cap meets the minimum code requirements Refer to Figure 39 and Ta...

Page 30: ... should be framed to 10 254 mm x 10 254 mm inside dimensions in the same manner as shown in Figure 21 4 Any occupied areas above the first floor including 45 elbows x2 Wall strap Plumber s tape connected to wal strap closets and storage spaces which the vertical vent passes through must be enclosed The enclosure may be framed and sheet rocked with standard building materials However consult the ap...

Page 31: ...upply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water solution after completing the required pressure test TO TEST VALVE PRESSURES The pressure taps are located on the top right of the valve shown in Figure 42 Turn set screw...

Page 32: ...g outlet DO NOT cut or remove the grounding prong from this plug CAUTION When servicing controls label all wires prior to disconnection Wiring errors can cause improper and dangerous operation Verify proper operation after servicing If any of the original wire as supplied with the appliance must be replaced it must be replaced with 18 AWG wire with a temperature rating of 105 C Figure 43 Proflame ...

Page 33: ...he unit Then remove the glass door by releasing the top spring latches 2 Next install the ember bed assembly as shown in Figure 44 by holding onto the slots in the ember bed The ember bed must be held at a 45 angle from left to right in order for it to fit inside the firebox When installed correctly it should butt against the back of the firebox 3 Install the back log as shown above in Figure 45 b...

Page 34: ...igure 49 Final Top Log 6 Next Install the left and right top logs as shown in Figure 48 Note the locating notches on the bottom side of both logs areas highlighted 7 Install the last log on top on the right side as shown in Figure 49 Note the locating notch on the bottom side that matches the half round on top of the large bottom log sitting on the ember bed NOTE While the glass is still removed i...

Page 35: ...on at ALL the burner ports If a long delay is noticed turn the appliance off and wait for it to cool down Then remove the glass and make sure none of the burner ports are blocked Maintenance Once a year the logs should be removed and checked for deterioration or large amounts of soot A small amount on the bottom side of the logs is normal Remove and replace the logs in the same manner described ab...

Page 36: ...retaining bolts Figure 51 using a 1 4 socket and remove the damaged screen while noting the orientation Install the new screen 50 3243 by simply re installing the retaining bolts Re install the cast door and top to finish Step 5 Remove the cast side left or right by loosening the two 2 top mount bolts Figure 47 using a 3 8 wrench Next lift up to remove the cast side and lay it down on a soft surfa...

Page 37: ...ill blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in intervals Additional Ignition Information 1 The Proflame 2 IFC will only attempt ignition once 2 The ignition attempt will last approximately 60 seconds 3 If no ignition is sensed after 60 seconds the IFC will lockout see ab...

Page 38: ...k the correct gas type settings on the valve and pilot burner assembly orifice Pilot will not remain lit Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC board Check pilot for full flame impingement around Flame Sensor If flame is too small check gas pressure adjust pilot rate screw check pilot head for damage Ensure the ground wire is properly attached ...

Page 39: ...r temperature Reset the Proflame IFC See Locking Conditions Flame lifting Leak in vent pipe Check for leaks in vent connections Improper vent configuration Check vent configuration with manual Terminal may be re circulating flue gases Check to see if terminal is on correctly May need to install high wind termination cap Contact dealer Blue Flames The heater has just been started Normal during star...

Page 40: ...yco Strain Relief EC 044 11 Domestic Power Cord 115v EC 042 12 Log Set 9 pieces 50 3234 13 Ceramic Burner Assembly 50 3233 14 Front Door Glass w Gasket 16 875 x 21 0625in 50 3235 15 Front Door Complete 50 3236 16 Side Door Glass w Gasket 15 875 x 11 625in 50 3237 17 Side Door Complete 50 3238 18 Ceramic Fluted Liner 1 piece 50 3239 19 Replacement Safety Screen Front 50 3243 20 Replacement Safety S...

Page 41: ...Parts List 18 1 21 2 4 11 10 16 17 20 15 13 19 14 23 9 8 3 7 6 5 22 12 41 ...

Page 42: ...d Antique Chestnut 50 3249 26 Cast Skirt Painted 50 3250 Cast Skirt Enameled Antique Chestnut 50 3251 27 Cast Right Side Painted 50 3252 Cast Right Side Enameled Antique Chestnut 50 3253 28 Cast Left Side Painted 50 3254 Cast Left Side Enameled Antique Chestnut 50 3255 29 Cast Leg Painted 1 piece 50 3256 Cast Leg Enameled Antique Chestnut 1 piece 50 3257 24 27 28 25 26 29 42 ...

Page 43: ...r including serial number This warranty does not cover any discoloration of the safety screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over firing due to incorrect setup or tampering Damage caused by incorrect installation To the Dealer Provide name ...

Page 44: ...________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy NATURAL GAS NAT PROPANE LPG INLET GAS PRESSURE _________in wc MAIN BURNER ORIFICE __________ DMS PILOT ORIFICE _________OR________in diam INSTALLER S SIGNATURE _____________________________________...

Reviews: