Enviro 50-1675 Owner'S Manual Download Page 14

Warranty

Exclusions and Limitations:

1.  This Warranty does not cover tarnish, discoloration or wear on the plating or paint.  

2.  This Warranty excludes wear and tear or breakage caused by cleaning, moving or service on log set.

3.  A qualified installer must install this stove or fireplace. This Limited Warranty covers defects in materials 

and workmanship only if the product has been installed in accordance with local building and fire codes; 

in their absence, refer to the owner’s manual. If the product is damaged or broken as a result of any 

alteration, willful abuse, mishandling, accident, neglect, or misuse of the product, the Limited Warranty 

does not apply.

4.  The stove must be operated and maintained at all times in accordance with the instructions in the 

Owner’s Manual. If the unit shows signs of neglect or misuse, it is not covered under the terms of this 

Warranty policy. Performance problems due to operator error will not be covered by the Limited Warranty 

policy.

5.  As this is a heating appliance some changes in colour of surface finishes may occur. This is not a flaw 

and as such is not covered under this warranty. 

6.  Some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not 

a defect and, therefore, is not covered under this Limited Warranty. 

7.  Misuse includes over-firing. Over-firing this appliance can cause serious damage and will nullify the 

Limited Warranty.

8.  The Limited Warranty will cover glass thermal breakage only and will not cover misuse of the stove glass, 

including but not limited to glass that is struck, has surface contaminates or has had harsh or abrasive 

cleaners used on it.

9.  This warranty does not cover products made or provided by other manufacturers and used in conjunction 

with the operation of this stove without prior authorization from Sherwood Industries Ltd. The use of 

such products may nullify the Limited Warranty on this stove. If unsure as to the extent of this Limited 

Warranty, contact your authorized Enviro dealer before installation.

10. Sherwood Industries Ltd. will not be responsible for inadequate performance caused by environmental 

conditions.

11. The Limited Warranty does not cover installation and operational related problems such as spillage 

caused by environmental conditions. Environmental conditions include but are not limited to nearby 

trees, buildings, roof tops, wind, hills, mountains, inadequate venting or ventilation, excessive offsets, 

negative air pressures or other influences caused by mechanical systems such as furnaces, fans, clothes 

dryers etc.

12. The Limited Warranty is void if:

 

a) The stove has been operated in atmospheres contaminated by chlorine, fluorine or other damaging 

chemicals.

 

b) The stove is subject to submersion in water or prolonged periods of dampness or condensation.

 

c) Any damage to the unit, combustion chamber or other components due to water, or weather damage 

which is the result of, but not limited to, improper chimney/venting installation.

 

c) Salt air in coastal areas or high humidity can be corrosive to the finish; these environments can cause 

rusting. Damage caused by salt air or high humidity is not covered by the Limited Warranty.

13. Exclusions to the Limited Warranty include: injury, loss of use, damage, failure to function due to 

accident, negligence, misuse, improper installation, alteration or adjustment of the manufacturer’s 

settings of components, lack of proper and regular maintenance, alteration, or act of God.

14. The Limited Warranty does not cover damage caused to the fireplace or stove while in transit. If this 

occurs, do not operate the stove and contact your courier and/or dealer.

 15. The Limited Warranty does not extend to or include firebox paint, door or glass gaskets with damage 

caused by normal wear and tear, or exterior paint discoloration or chipping, worn gaskets, etc.

16. The Limited Warranty does not include damage to the unit caused by abuse, improper installation, or 

modification of the unit.

14

Summary of Contents for 50-1675

Page 1: ...PERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESP...

Page 2: ...dations 4 Operating Instructions 6 Dimensions Specifications 6 Control Board Functions 7 Automatic Safety Features of Your Pellet Stove 7 Operating Your Pellet Stove 7 Turning Your Pellet Stove Off 9...

Page 3: ...stove needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLINKERING clinkers are silica sand or other impurities in the fuel that will form a hard mass during the...

Page 4: ...ertain the chimney and its lining have not been damaged OPERATION The door and ash drawer must be kept closed when the unit is in operation to prevent fume spillage and for proper and safe operation o...

Page 5: ...bearing capacity if existing construction doesn t meet load capacity suitable measures e g load distributing plate must be taken to achieve it DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYST...

Page 6: ...ations Description Fuel type Residential Pellet Heater 6mm 1 4 dia Pellets wood corn wheat barley grass only Voltage Current Max Power 110 120 V 4 2 Amps 504 Watts Frequency Hopper Capacity Consumptio...

Page 7: ...nd arrow down to decrease heat 7 FEED TRIM BUTTON Used in conjunction with the Heat Level adjustment buttons to adjust the Feed Trim It can be increased by two 2 feed settings or it can be decreased b...

Page 8: ...lished the convection blower will turn on after ten 10 minutes and the Fuel Type Light will turn solid To OPERATE Press the Heat Level buttons to change the desired Heat Level Output setting The speed...

Page 9: ...stove will turn off AUTO OFF mode To turn the unit OFF turn the Thermostat down or Timer off n shut down the burn pot agitator will run continualy for two 2 minutes when on Pellet Fuel Type and fifte...

Page 10: ...the agitator towards the back of the firebox to unlock it slide it to the left and lift it out of the burn pot liner 4 Lift the burn pot liner out of the stove 5 Lift the burn pot from the firebox by...

Page 11: ...fter extended use the gasketing may come loose To repair this glue the gasketing on using high temperature fiberglass gasket glue available from your local dealer This is important to maintain an airt...

Page 12: ...The blower motors has sealed bearings DO NOT lubricate this motor Check gaskets and replace if needed POST SEASON CLEAN UP Once you are finished using the pellet appliance for the season unplug the s...

Page 13: ...n restrictions and exclusions apply to this warranty Limited Two 2 Year Warranty Under this warranty Sherwood Industries Ltd covers Ignitor Auger Motor Circuit Board Timers Temp Sensors Blowers Vacuum...

Page 14: ...ify the Limited Warranty on this stove If unsure as to the extent of this Limited Warranty contact your authorized Enviro dealer before installation 10 Sherwood Industries Ltd will not be responsible...

Page 15: ...vered per our warranty service fee reimbursement schedule Labour rates are set per component and as such total labour costs may not be covered 27 Sherwood Industries Ltd is not liable for freight or l...

Page 16: ...AL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy MAGNEHELIC AT INSTALL ___________________ INSTALLER S SIGNATURE ____________...