Installation
Figure 14: Removable fl ue collar in place.
Figure 15: Leveling legs.
S
URROUND
P
ANEL
S
EALED
I
NSTALLATION
F
OR
USA O
NLY
:
Note:
Though this is an allowable installation, we do not recommend it because of the possibility of poor
draft, and therefore poor stove performance.
Before starting this type of installation refer
to I
NSTALLATION
- M
ASONRY
F
IREPLACE
I
NSTALLATION
- I
NSERT
for additional information. For
clearances refer to S
PECIFICATIONS
- C
LEARANCES
T
O
C
OMBUSTIBLES
- 1200 KI I
NSERT
and
S
PECIFICATIONS
- C
LEARANCES
T
O
C
OMBUSTIBLES
-
1700 KI I
NSERT
.
1. Before the face plate is installed onto
the unit, glue a 6” (150mm) wide R20
fi berglass insulation strip around the
perimeter of the back of the panels using
RTV silicon or stove gasket cement.
When the face plate is installed onto
the unit the insulation must overlaps the
fi replace opening to form a seal between
the masonry fi replace and the unit’s face
plate. Let the silicon or cement dry.
2. To make the installation of the surround
panel onto the unit easy have the unit 6”
(150mm) out from the fi replace,
3. Push the insert into the fi replace, allowing
the insulation to form a seal between
the panels and the fi replace. Tuck any
exposed insulation behind the face plate.
Figure 16: Installation with Surround Sealed.
Masonry Fireplace
Mantel
Damper Removed
or Fastened Open
Surround Panel
USA 16” (406 mm)
CND 18” (450 mm)
Insulation Around the
Back of the Face Plate
NOTE:
To use this type of installation we
recommend your chimney have a minimum
cross-sectional area of 28 and a maximum of
144 square inch. If it is not within this range
your chimney may not have sufficient draw
for the fireplace to operate correctly. The
required cross-section may vary depending
on climate and if the chimney is inside (better)
or outside.
4.
Screw or nail the provided metal plate with the
wording “THIS FIREPLACE HAS BEEN ALTERED
TO ACCOMMODATE A FIREPLACE INSERT AND
SHOULD BE INSPECTED BY A QUALIFIED PERSON
PRIOR TO THE RE-USE AS A CONVENTIONAL
FIREPLACE.” to the inside of the fi replace.