ET2-GLD24.1 GOOSENECK BENCH MOUNTED SENSOR TAP TROUBLESHOOTING

 

 

Initial Checks: 

 

 

C

HECK 

W

ATER 

S

UPPLY

;  

 

U

NPLUG ALL CABLES

,

 INCLUDING THE PLUG BETWEEN THE BATTERY BOX AND THE SOLENOID

,

 LEAVE 

UNPLUGGED FOR 

5

 MINUTES

 (

THIS GIVES THE ELECTRONICS A CHANCE TO RESET

); 

 

C

HECK BATTERIES ARE INSTALLED CORRECTLY

,

 CONSIDER REPLACING BATTERIES 

(

EVEN IF TAP IS 

MAINS POWERED

)

 AS THIS WILL HIGHLIGHT ANY FAULT WITH POWER SUPPLY

/

OUTLET

.

 CHECK 

CONNECTIONS FOR SIGN OF DAMAGE

 

C

HECK SENSOR WINDOW IS CLEAN AND UNOBSTRUCTED

;  

 

R

ECONNECT CABLES AND CONNECTIONS CAREFULLY AND RE

-

TEST

 

I

F RED LIGHT IS INDICATING WHEN HANDS ARE IN THE ACTIVATION ZONE AND YOU CAN HEAR THE 

SOLENOID CLICKING BUT NO WATER IS COMING OUT 

 VALVE IS BLOCKED OR OBSTRUCTED

 

C

LEAN VALVE AND RE

-

TEST

 

 

NOTE

: If red light is on or flashing, this indicates that the unit is functioning correctly, 

although there may not be enough power to activate the solenoid. A flashing red light 
indicates that batteries are low and need replacing.  

Issue 

 Intermittent Self-Activation (Tap activates when no-one is using it) 

If the tap has just been installed 

 give it a few moments as the sensor needs time to adjust 

to the environment and will normally settle down on its own. If it doesn’t, it is l

ikely to be a 

reflective  light  issue  which  is  usually  resolved  by  carrying  out  either  Reset  1  or  2  detailed 
below. 
 

RESET 1: 

 

 

E

NSURE THAT THE TAP HAS BEEN INSTALLED AT A MINIMUM DISTANCE OF 

250

MM FROM THE BOTTOM 

OF THE BASIN

 

L

OCATE THE RED

/

BLACK RESET BUTTON ON THE CONTROL BOX

,

 PUSH AND HOLD FOR 

3

 SECONDS 

ENSURING THAT NOTHING IS UNDERNEATH THE SENSOR

.

 

N.B.

 SENSOR FIELD 

MUST

 BE KEPT CLEAR FOR 

A FULL 

60

 SECONDS

.

 

O

NCE THE 

60

 SECONDS IS UP

,

 TEST TO SEE IF TAP IS WORKING

.

 

 

 

RESET 2: 

 

 

L

OCATE THE RED

/

BLACK RESET BUTTON ON THE CONTROL BOX

,

 PUSH AND HOLD FOR 

3

 SECONDS BUT 

AT

 

THE

 

SAME

 

TIME

 

 HOLD YOUR HAND UNDER THE SENSOR AT THE HEIGHT YOU WANT THE SENSOR TO 

DETECT AND ACTIVATE

.

 

N.B.

 

Y

OU MUST HOLD YOUR HAND IN PLACE FOR A FULL 

60

 SECONDS TO GIVE 

THE ELECTRONICS A CHANCE TO ADJUST TO THE NEW SETTING

.

 

Y

OU MAY HAVE TO PERFORM THIS RESET 

A COUPLE OF TIMES UNTIL IT IS WORKING CORRECTLY AT THE HEIGHT YOU REQUIRE

.

 

 

 
NOTE

:  The  Reset  2  procedure  alters  the  pre-set  sensor  distance.  If  it  does  not  solve  your 

reflectivity issue, you may need to alter the position of the tap in relation to the basin, adjust 
your bathroom lighting or consider an alternative model. Reflective light can and will activate 
sensor taps, it is not a product fault