INSTALLATION INSTRUCTIONS ELITE TAPWARE BENCH MOUNTED
Elite Tapware Bench Mounted
TECHNICAL SPECIFICATION
Function
Power Input
Power Consumption
Water Pressure
Inlet/outlet Diameter
Detection Zone
Confirmation Time
Power Supply
DC: 6V (4X1.5V AA alkaline batteries) AC:220-240V (50/60Hz)
4 AA alkaline batteries or transformer
<0.3MW
100kPa-500kPa
15mm 1/2G
1 second
We strongly recommend that you use a qualified and registered plumber
and electrician.You must ensure that all pipe work is flushed adequately,
particularly in new builds or where lines have been disrupted.Components
of sensor taps are particularly susceptible to debris and will require more
thorough flushing than a standard plumbing fixture. Failure to flush lines
adequately will result in blocked or leaking valves (check/solenoid) or a
dripping tap soon after installation and is not covered by the Enviro-Tech
warranty.
Aerator
Sensor
Nut
Threaded tube
Control
cable
Attention:
Hold the plug not the wire to connect
and disconnect and make sure the
pins align to the holes in the right position.
Screw
Lid
Batteries
Base
Black plug
(Transformer Purchased Separately)
Washer
Mixing valve
Scald Prevention
5% cold water feeds in to the hot feed for safety purposes
Self adjusting
WARNING
:
Handle the connecting plugs carefully. Pulling too roughly on the plugs will damage them.
Take particular care when connecting/disconnecting the tap control cable to/from the battery box as it can be pulled out from the
body of the tap.
Any rough handling will cause your tap not to function and is not covered by your product warranty.