Chapter 6
Troubleshooting & Repairs
6-12
its position and speed. Adjust the sensors to protect these components. The following table
describes the locations of the proximity sensors:
1.
Gain access to the proximity sensor mounted on the compactor. See Table 6-2 for
the locations.
2.
Disconnect the sensor from the cable or extension cable.
3.
Loosen the nut that secures the sensor, and thread the sensor out of the holder.
4.
Thread the replacement sensor into position until it makes contact with either the
gear tooth or the plate, whichever is applicable. Back out to the appropriate clear-
ance distance (see Table 6-2 and Figure 6-7).
5.
Firmly tighten the nut to secure the sensor. Do not over-tighten it.
FIGURE 6-7.
Example of the sensor spacing on a gear
TABLE 6-2.
Proximity Sensor Locations
Component
Proximity Sensor Location
Clearance
Can flattener
Above gear
¾ turn
PET flattener
Above gear
¾ turn
Glass crusher
Left side of the gear
¾ turn
Sorting Cylinder
Rear of cylinder
½" from plate