4.  Mounting and installation 

The AirSafe PM can be mounted on any flat surface or on a wall using mounting brackets (ENVEA recommend 

to 

install the sensor in a flat position if possible). The sensor is designed for monitoring ambient air in workplaces in 
industries such as cement plants, foundries, wood workshops, incineration plants or logistic warehouses.

The AirSafe PM can be easily mounted to most surfaces and areas:

•  In or around process areas
•  Storage rooms
•  Laboratories
• 

Breakrooms

•  Changing rooms
• 

In or around office areas

•  Other footfall areas of health and safety exposure concern
•  Areas of air quality monitoring requirements

Install the AirSafe PM as near as possible to air intakes, areas of air movement, and areas of static air/settlement 
where people work. When positioned near the ventilation and filtration apparatus, the AirSafe PM can be used 
to monitor the effectiveness of the ventilation and filtration process.

 Attention!

 

AirSafe PM can be used only indoors, DO NOT use outdoors.

Summary of Contents for AirSafe PM

Page 1: ...ERATING INSTRUCTIONS AirSafe PM CONTINUOUS INDOOR MONITOR FOR DUST EXPOSURE ENVEA Process GmbH Gutedelstra e 31 79418 Schliengen GERMANY Tel 49 0 7635 827248 0 info process envea global www envea glob...

Page 2: ...3 8 Limits of use 6 4 Mounting and installation 7 5 Electrical connection 8 6 Setup 9 6 1 USB connection 9 6 2 Service software 10 6 2 1 List 10 6 2 2 Dust 11 6 2 3 Trend PM 13 6 2 4 Trend Avg 14 6 2...

Page 3: ...3 1 System overview A complete system consist of a AirSafe PM with its optional wall mounting bracket Fig 1 Drawing of AirSafe PM 290 1 mm 259 mm 107 mm...

Page 4: ...s size glossary PM describe all dust particles smaller than the mentioned size Example PM1 include all dust particles smaller than 1 m PM2 5 include all dust particles smaller than 2 5 m PM4 5 include...

Page 5: ...ust be worn to avoid injuries caused by possible sharp edges on the measuring device When using a cable with more than 4 cores unused open cores may cause sparking Failure to comply with the specified...

Page 6: ...echnical developments without prior notice If any queries arise ENVEA will be happy to inform customers of any possible changes made 3 6 Reliability For any additional information concerning product r...

Page 7: ...most surfaces and areas In or around process areas Storage rooms Laboratories Breakrooms Changing rooms In or around office areas Other footfall areas of health and safety exposure concern Areas of a...

Page 8: ...data B OC 2 Non attributed OC 2 Non attributed OC 1 Non attributed OC 1 Non attributed Iout A Current output for A Dust Iout A Current output for A Dust Iout E Current output for E Dust Iout E Curren...

Page 9: ...tem WinXP or more recent 6 1 USB connection For connection via USB it is necessary to open the sensor 1 Remove the screw caps on the four corners of the sensor 2 Remove the screws 3 Open the sensor 4...

Page 10: ...t dust value in mg m3 as well as ambient temperature and air moisture Firmwire version is also displayed Chanel 1 Provide instant values Chanel 2 Provide 15 minutes average values Chanel 3 Provide 8 h...

Page 11: ...int High Curr Out No The sensor has 2 analog output Output 1 for E Dust Output 2 for A Dust Write parameters It will save the parameters in the sensors Read parameters It will read the parameters from...

Page 12: ...exposure value to A Dust for 15 mins E Dust Long limit Limit exposure value to E Dust for 15 mins Sensor Usage T min max Minimum and maximum temperature in C that the sensor has been exposed to Module...

Page 13: ...average i Instant average 15 15 minutes average sh Shift 8 hours average Save to File It will generate a csv file containing the data of the graph display Zoom You can zoom on in out time frame Posit...

Page 14: ...temperature and moisture with up to 3 times average i Instant average 15 15 minutes average sh Shift 8 hours average Zoom You can zoom on in out time frame Position You can slide the graph on the lef...

Page 15: ...eters PC Modbus parameters You can change the baud rate and the com port Write sensor parameters in file This will generate a file with all parameters of the sensor It can be saed and stored on any su...

Page 16: ...fault Password is 123456789 Use a web browser and input 192 168 43 1 esam press ENTER 192 168 43 1 esam 7 2 How to connect as ADMIN profile languages 7 2 1 ADMIN Select Change Profile Guest Default lo...

Page 17: ...w Logout To logout and go back to guest mode Help About Not in use yet Reboot You can reboot eSAM interface My account Preferences You can select the default page that will be displayed at each connec...

Page 18: ...menu another click will remove them from chart You can select the time period 30 1H 2H All You can adjust the scale Min for Minimum Max for Maximum You can quickly export the values seen on the screen...

Page 19: ...h or as a chart and a tool can calculate the min max average values On the left panel you can choose the dust type You can select the period of time of data From 2022 08 07 00 00 00 2022 08 08 00 00 0...

Page 20: ...20 7 5 Settings Site Equipment Channels Analog outputs Modbus outputs Logic states Pages Process Initialization Site name You can rename the sensor Languages You can switch sensor language...

Page 21: ...the standard unit is mg m3 the Coef is 1 If for exemple you want to have an output in g m3 you will ne to have a Coef A 1000 The save panel offer you the possibility to save sensor settings and to upd...

Page 22: ...les block Pay attention to the connector position and make sure it is connected Step 5 Place the protective metalic cover Step 6 Install the 2 screws 9 Warranty ENVEA provides a warranty of 1 year fro...

Page 23: ...mit violations Counting of phases with violations of long term limits Counting of recovery phases inbetween them Humidity compensation Yes Dust material density adjustment Yes Limits for dust concentr...

Reviews: