background image

User Manual 

 

DIN-ODE Mk2 MANUAL  

 

For latest version visit:

 

www.enttec.com

 

 

ID:

 

373037

 

 

Disabled: only one source should be sending to 

the  DMX  output.  Using  multiple  sources  will 

cause a conflict and the output might have unex-

pected data.  

 

HTP  Merge  (by  default):  Highest  Takes  Prece-
dence. Channels are compared one to one and 

the highest value is set on the output. Merging is 

limited  to  two  sources,  any  additional  sources 

will  be  ignored  by  ODE.  If  either  one  of  the  2 

sources of DMX stop, the failed source is held in 

the merge buffer for 4 seconds. If, during the 4 

second timeout, the failed source returns, Merg-

ing continues. 

 

LTP Merge: Latest Takes Precedence. The latest 
source  is  used  as  the  output.  The  source  that 

hasn’t been received

 for 4 seconds or more, will 

be discarded. 

 

Merging  conflict:  if  more  than  two  sources  are 
sending data to ODE on the same universe, ODE 

will  indicate  a  conflict.  A  warning  will  be  dis-

played on the home-page, and i

t’s also indicated 

by the status led blinking faster than normal. 

Unicast option 

Send DMX to a single IP address rather than broadcast. 
Unicast is only available when port is set to Input. Any 

valid IP address can be used to Unicast DMX.  

Save or Reset 

To save all the changes made, please click on Save Set-

tings and wait for ODE to confirm (takes up-to 5 seconds). 

Once confirmed you will be taken to the home-page. 

Reset to defaults, will put all the settings back to their 
default values (network & port settings). ODE will be re-

set to Factory condition. 

Reboot 

 will restart the ODE. Please allow a few seconds, 

and the page will refresh, when ODE is ready. 

Update Firmware 

From this page you can update ODE to the latest firm-

ware. Latest firmware file is available at 

enttec.com/din-

ode2

Please use the correct firmware file. 

 

Choose or browse the firmware file (as per your browser) 

and click on Update firmware to start the process. The 

update progress is shown in real-time, and will take a few 

seconds for the update to complete 

When the update is complete, the page will refresh and you 

will be taken to the home page 

 where you can verify the 

firmware version. If the update fails for any reason, please 

try the same process again. 

ODE will reboot after a firmware update, please allow a few 
seconds for it to be refreshed in the browser. Please wait 

until the update process is complete. 

 

Art-Net Send Test 

 

NMU can also be used to troubleshoot the DMX output on 

your ODE. Art-Net Test can be accessed from the top menu: 

Art-net 

 Art-net

 Test

 

 

When first opened, the Art-Net is set to Disabled, please set 

it to Enabled, and then you can use either the DMX faders 

to test one or more DMX channels, or use the test-patterns 

from the options available.  

Please set the ODE to be Art-Net output and on the same 

universe as being used to send Art-Net from NMU. 

Reviews: