User Manual
DIN-ODE Mk2 MANUAL
For latest version visit:
www.enttec.com
4
ID:
373037
Disabled: only one source should be sending to
the DMX output. Using multiple sources will
cause a conflict and the output might have unex-
pected data.
HTP Merge (by default): Highest Takes Prece-
dence. Channels are compared one to one and
the highest value is set on the output. Merging is
limited to two sources, any additional sources
will be ignored by ODE. If either one of the 2
sources of DMX stop, the failed source is held in
the merge buffer for 4 seconds. If, during the 4
second timeout, the failed source returns, Merg-
ing continues.
LTP Merge: Latest Takes Precedence. The latest
source is used as the output. The source that
hasn’t been received
for 4 seconds or more, will
be discarded.
Merging conflict: if more than two sources are
sending data to ODE on the same universe, ODE
will indicate a conflict. A warning will be dis-
played on the home-page, and i
t’s also indicated
by the status led blinking faster than normal.
Unicast option
Send DMX to a single IP address rather than broadcast.
Unicast is only available when port is set to Input. Any
valid IP address can be used to Unicast DMX.
Save or Reset
To save all the changes made, please click on Save Set-
tings and wait for ODE to confirm (takes up-to 5 seconds).
Once confirmed you will be taken to the home-page.
Reset to defaults, will put all the settings back to their
default values (network & port settings). ODE will be re-
set to Factory condition.
Reboot
–
will restart the ODE. Please allow a few seconds,
and the page will refresh, when ODE is ready.
Update Firmware
From this page you can update ODE to the latest firm-
ware. Latest firmware file is available at
enttec.com/din-
ode2
.
Please use the correct firmware file.
Choose or browse the firmware file (as per your browser)
and click on Update firmware to start the process. The
update progress is shown in real-time, and will take a few
seconds for the update to complete
When the update is complete, the page will refresh and you
will be taken to the home page
–
where you can verify the
firmware version. If the update fails for any reason, please
try the same process again.
ODE will reboot after a firmware update, please allow a few
seconds for it to be refreshed in the browser. Please wait
until the update process is complete.
Art-Net Send Test
NMU can also be used to troubleshoot the DMX output on
your ODE. Art-Net Test can be accessed from the top menu:
Art-net
→
Art-net
Test
When first opened, the Art-Net is set to Disabled, please set
it to Enabled, and then you can use either the DMX faders
to test one or more DMX channels, or use the test-patterns
from the options available.
Please set the ODE to be Art-Net output and on the same
universe as being used to send Art-Net from NMU.