Servicing, Inspection & Maintenance 

 

The device has no user serviceable parts. If your installation has become damaged, parts should be 

replaced.

 

 

Power down the device and ensure a method is in place to stop the system from becoming energized 

during servicing, inspection & maintenance.

 

 

Key areas to examine during inspection:

 

 

Ensure all connectors are mated securely and show no sign of damage or corrosion.

 

 

Ensure all cabling has not obtained physical damage or been crushed.

 

 

Check for dust or dirt build up on the device and schedule cleaning if necessary.

 

 

Dirt or dust buildup can limit the ability for a device to dissipate heat and can lead to damage.

 

 

The replacement device should be installed in accordance with all steps within the installation guide.

 

To 

order replacement devices or accessories contact your reseller or message ENTTEC directly.

 

Cleaning 

Dust and dirt build up can limit the ability for the device to dissipate heat resulting in damage. It’s important 

that the device is cleaned in a schedule fit for the environment it is installed within to ensure maximum 

product longevity.

 

Cleaning schedules will vary greatly depending on the operating environment. Generally, the more extreme 

the environment, the shorter the interval between cleaning.

 

 

 

Before cleaning, power down your system and ensure a method is in place to stop the system from 

becoming energized until cleaning is complete.

 

 

 

Do not use abrasive, corrosive, or solvent-based cleaning products on an device.

 

 

Do not spray device or accessories. The device is an IP20 product. 

 

 

To clean an ENTTEC device, use low-pressure compressed air to remove dust, dirt and loose particles. If 

deemed necessary, wipe the device with a damp microfiber cloth.

 

A selection of environmental factors that may increase the need for frequent cleaning include:

 

 

Use of stage fog, smoke or atmospheric devices.

 

 

High airflow rates (i.e., in close proximity to air conditioning vents).

 

 

High pollution levels or cigarette smoke.

 

 

Airborne dust (from building work, the natural environment or pyrotechnic effects).

 

If any of these factors are present, inspect all elements of the system soon after installation to see whether 

cleaning is necessary, then check again at frequent intervals. This procedure will allow you to determine a 

reliable cleaning schedule for your installation. 

 

 

Summary of Contents for 70407

Page 1: ...infrastructure Connectors with EtherCon lockable feature in addition make the wiring secured with a peace of mind The configuration as well as the firmware updates of the ODE MK3 are managed through t...

Page 2: ...ion Safety Guidelines 4 Wiring Diagrams 4 Hardware Features 5 DMX Connectors 5 LED Status Indicator 5 PoE Power over Ethernet 6 Functional Features 6 Bi directional eDMX Protocols and USITT DMX512 A C...

Page 3: ...mediately if accessories power cables or connectors is in any way damaged defective shows signs of overheating or are wet Provide a means of locking out power to your installation for system servicing...

Page 4: ...oducts Once installation is completed check that all hardware and components are securely in place and fastened to supporting structures if applicable Installation Safety Guidelines The device is conv...

Page 5: ...depending on the settings set within the Web Interface 5pin DMX OUT DMX IN Pin 1 0V GND Pin 2 Data Pin 3 Data Pin 4 NC Pin 5 NC Any suitable 3 to 5pin DMX adaptor can be used to connect to 3pin DMX ca...

Page 6: ...r Broadcast Multicast Art Net DMX RDM Supported Art Net 1 2 3 4 are supported Each port s configuration can be defined using the ODE MK3 s web interface to define a universe in the range 0 to 32767 RD...

Page 7: ...ork does not have a DHCP server the ODE MK3 will fall back to the Static IP address which will be 192 168 0 10 as default The ODE MK3 will also be set as DMX Input as default listening to DMX512 A and...

Page 8: ...ices on a local network Devices can be discovered using Art Poll i e DMX Workshop if set to use Art Net The device Default IP address 192 168 0 10 is printed on the physical label on the rear of the p...

Page 9: ...mmunication Control4 Support Pressing this button will send a SDDP Simple Device Discovery Protocol packet to allow faster configuration in discovery in Control4 s Composer software Type Choose from t...

Page 10: ...cast address 192 168 0 11 Port 1 Universe 0 Port 2 Universe 0 RDM disabled Restart Now Please allow up to 10 seconds for the device to reboot When the web interface page refreshes the ODE MK3 is ready...

Page 11: ...or the device to dissipate heat resulting in damage It s important that the device is cleaned in a schedule fit for the environment it is installed within to ensure maximum product longevity Cleaning...

Page 12: ...kage Contents ODE MK3 Ethernet Cable Power supply with AU EU UK US adapters Ordering Information For further support and to browse ENTTEC s range of products visit the ENTTEC website Item Part No ODE...

Reviews: