Safety 

Ensure  you  are  familiarized  with  all  key  information  within  this  guide  and  other  relevant  ENTTEC 

documentation before specifying, installing, or operating an ENTTEC device. If you are in any doubt about 

system safety, or you plan to install ENTTEC device in a configuration that is not covered within this guide, 

contact ENTTEC or your ENTTEC supplier for assistance. 

 

ENTTEC’s return to base warranty for this product does not cover damage caused by inappropriate use, 

application, or modification to the product.

 

Electrical safety 

 

This  product  must  be  installed  in  accordance  with  applicable  national  and  local  electrical  and 

construction codes by a person familiar with the construction and operation of the product and the 

hazards involved. Failure to comply with the following installation instructions may result in death or 

serious injury.

 

 

Do not exceed the ratings and limitations defined in the product datasheet or this document. Exceeding 

can cause damage to the device, risk of fire and electrical faults.

 

 

Ensure that no part of the installation is or can be connected to power until all connections and work 

is complete. 

 

 

Before applying power to your installation, ensure your installation follows the guidance within this 

document. Including checking that all power distribution equipment and cables are in perfect condition 

and  rated  for  the  current  requirements  of  all  connected  devices  and  factor  in  overhead  as  well  as 

verifying that it is appropriately fused and voltage is compatible.

 

 

Remove power from your installation immediately if accessories power cables or connectors is in any 

way damaged, defective, shows signs of overheating or are wet.

 

 

Provide  a  means  of  locking  out  power  to  your  installation  for  system  servicing,  cleaning  and 

maintenance. Remove power from this product when it is not in use. 

 

 

Ensure your installation is protected from short circuits and overcurrent. Loose wires around this device 

whilst in operation, this could result in short circuiting.

 

 

Do not over stretch cabling to the device’s connectors and ensure that cabling does not exert force on 

the PCB.

 

 

Do not ‘hot swap’ or ‘hot plug’ power to the device or its accessories. 

 

 

Do not connect any of this device’s V- (GND) connectors to earth.

 

 

Do not connect this device to a dimmer pack or mains electricity.

 

System Planning and Specification 

 

To contribute to an optimal operating temperature, where possible keep this device out of direct sunlight.

 

 

Any twisted pair, 120ohm, shielded EIA-485 cable is suitable to transmit DMX512 data. The DMX cable 

should be suitable for EIA-485 (RS-485) with one or more low capacitance twisted pairs, with overall 

braid and foil shielding. Conductors should be 24 AWG (7/0.2) or larger for mechanical strength and to 

minimize volt drop on long lines.

 

 

A maximum of 32 devices should be used on a DMX line before re-generating the signal using a DMX 

buffer/ repeater / splitter. 

 

 

Always terminate DMX chains using a 120Ohm resistor to stop signal degradation or data bounce-back. 

 

 

The  maximum  recommended  DMX  cable  run  is  300m  (984ft).  ENTTEC  advises  against  running  data 

cabling  close  to  sources  of  electromagnetic  interference  (EMF)  i.e.,  mains  power  cabling  /  air 

conditioning units.

 

 

This device has an IP20 rating and is not designed to be exposed to moisture or condensing humidity.

 

 

Ensure this device is operated within the specified ranges within its product datasheet.

 

Summary of Contents for 70407

Page 1: ...infrastructure Connectors with EtherCon lockable feature in addition make the wiring secured with a peace of mind The configuration as well as the firmware updates of the ODE MK3 are managed through t...

Page 2: ...ion Safety Guidelines 4 Wiring Diagrams 4 Hardware Features 5 DMX Connectors 5 LED Status Indicator 5 PoE Power over Ethernet 6 Functional Features 6 Bi directional eDMX Protocols and USITT DMX512 A C...

Page 3: ...mediately if accessories power cables or connectors is in any way damaged defective shows signs of overheating or are wet Provide a means of locking out power to your installation for system servicing...

Page 4: ...oducts Once installation is completed check that all hardware and components are securely in place and fastened to supporting structures if applicable Installation Safety Guidelines The device is conv...

Page 5: ...depending on the settings set within the Web Interface 5pin DMX OUT DMX IN Pin 1 0V GND Pin 2 Data Pin 3 Data Pin 4 NC Pin 5 NC Any suitable 3 to 5pin DMX adaptor can be used to connect to 3pin DMX ca...

Page 6: ...r Broadcast Multicast Art Net DMX RDM Supported Art Net 1 2 3 4 are supported Each port s configuration can be defined using the ODE MK3 s web interface to define a universe in the range 0 to 32767 RD...

Page 7: ...ork does not have a DHCP server the ODE MK3 will fall back to the Static IP address which will be 192 168 0 10 as default The ODE MK3 will also be set as DMX Input as default listening to DMX512 A and...

Page 8: ...ices on a local network Devices can be discovered using Art Poll i e DMX Workshop if set to use Art Net The device Default IP address 192 168 0 10 is printed on the physical label on the rear of the p...

Page 9: ...mmunication Control4 Support Pressing this button will send a SDDP Simple Device Discovery Protocol packet to allow faster configuration in discovery in Control4 s Composer software Type Choose from t...

Page 10: ...cast address 192 168 0 11 Port 1 Universe 0 Port 2 Universe 0 RDM disabled Restart Now Please allow up to 10 seconds for the device to reboot When the web interface page refreshes the ODE MK3 is ready...

Page 11: ...or the device to dissipate heat resulting in damage It s important that the device is cleaned in a schedule fit for the environment it is installed within to ensure maximum product longevity Cleaning...

Page 12: ...kage Contents ODE MK3 Ethernet Cable Power supply with AU EU UK US adapters Ordering Information For further support and to browse ENTTEC s range of products visit the ENTTEC website Item Part No ODE...

Reviews: